Commissioning and clinical implementation of a mega-voltage cone beam CT system for treatment localization.

Olivier Gayou1, Moyed Miften.   

Abstract

The improvement in conformal radiotherapy techniques with steep dose gradients has allowed for the delivery of higher doses to a tumor volume while maintaining the sparing of surrounding normal tissue. In this situation, verification of patient setup and evaluation of internal organ motion just prior to radiation delivery is a crucial step. To this end, several volumetric image-guided techniques have been developed for patient localization, such as the Siemens MVision mega-voltage cone beam CT (MV-CBCT) system. In this work, the commissioning and clinical implementation of the MVision system is presented. The geometry and gain calibration procedures for the system are described, and guidelines for quality assurance procedures are provided. Different MV-CBCT clinical protocols, ranging from daily to weekly image-guidance, which includes image acquisition, reconstruction, registration with planning CT, and treatment couch offsets corrections, were commissioned. The image quality characteristics of the MVision system were measured and assessed qualitatively and quantitatively, including the image noise and uniformity, low-contrast resolution, and spatial resolution. Furthermore, the image reconstruction and registration software was evaluated. Data show that a 2 cm large object with 1% electron density contrast can be detected with the MVision system with 10 cGy at isocenter and that the registration software is accurate within 2 mm in the anterior-posterior, left-right, and superior-inferior directions.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17879781     DOI: 10.1118/1.2752374

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

1.  In vivo reproducibility of robotic probe placement for a novel ultrasound-guided radiation therapy system.

Authors:  Muyinatu A Lediju Bell; H Tutkun Sen; Iulian Iordachita; Peter Kazanzides; John Wong
Journal:  J Med Imaging (Bellingham)       Date:  2014-07-23

2.  Noise power properties of a cone-beam CT system for breast cancer detection.

Authors:  Kai Yang; Alexander L C Kwan; Shih-Ying Huang; Nathan J Packard; John M Boone
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

3.  Megavoltage CT imaging quality improvement on TomoTherapy via tensor framelet.

Authors:  Hao Gao; X Sharon Qi; Yu Gao; Daniel A Low
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

4.  Assessment and evaluation of MV image guidance system performance in radiotherapy.

Authors:  Nithya Kanakavelu; E James Jebaseelan Samuel
Journal:  Rep Pract Oncol Radiother       Date:  2015-02-07

5.  Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction.

Authors:  Benjamin P Fahimian; Yunzhe Zhao; Zhifeng Huang; Russell Fung; Yu Mao; Chun Zhu; Maryam Khatonabadi; John J DeMarco; Stanley J Osher; Michael F McNitt-Gray; Jianwei Miao
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

6.  Evaluation of mechanical and geometric accuracy of two different image guidance systems in radiotherapy.

Authors:  Nithya Kanakavelu; Anand Mambakam Ravindran; Emmanvelrajan James Jebaseelan Samuel
Journal:  Rep Pract Oncol Radiother       Date:  2016-01-04

7.  Technical Note: Iterative megavoltage CT (MVCT) reconstruction using block-matching 3D-transform (BM3D) regularization.

Authors:  Qihui Lyu; Chunlin Yang; Hao Gao; Yi Xue; Daniel O'Connor; Tianye Niu; Ke Sheng
Journal:  Med Phys       Date:  2018-04-30       Impact factor: 4.071

8.  Prostate image-guided radiotherapy by megavolt cone-beam CT.

Authors:  Sergio Zucca; Barbara Carau; Ignazio Solla; Elisabetta Garibaldi; Paolo Farace; Giancarlo Lay; Gianfranco Meleddu; Pietro Gabriele
Journal:  Strahlenther Onkol       Date:  2011-07-22       Impact factor: 3.621

9.  Set-up error validation with EPID images: Measurements vs Egs_cbct simulation.

Authors:  D van Eeden; F H J O'Reilly; F C P du Plessis
Journal:  Rep Pract Oncol Radiother       Date:  2019-10-21

10.  Evaluation of imaging performance of major image guidance systems.

Authors:  Mf Chan; J Yang; Y Song; C Burman; P Chan; S Li
Journal:  Biomed Imaging Interv J       Date:  2011-04-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.