Study of the effects of tissue reactions on the function of implanted glucose sensors.

Paul Dungel1, Nathan Long, Bazhang Yu, Yvonne Moussy, Francis Moussy.   

Abstract

The relationship between tissue reactions to a subcutaneously implanted glucose sensor and the function of the sensor was evaluated over a period of 4-weeks using tubular, porous polyvinyl alcohol (PVA) sponges implanted subcutaneously in rats. The PVA sponges were used as scaffolds in which the foreign body response could develop. Coil-type glucose sensors were then placed in the center of the PVA sponges and tested on day 3, and weekly thereafter. In the first approach, the sensors were placed in the sponges still implanted in the rats and tested. In vivo glucose sensor sensitivity peaked at day 7 and steadily decreased until day 35. In the second approach, the sensors were placed in the explanted sponges and then tested. This test showed no sensor function after day 7, indicating that functional blood vessels are critical in maintaining any function whatsoever. In both cases the sensors themselves were never implanted to eliminate any potential in vivo degradation of the sensors that could have affected the outcome of this study. Sensors were then tested in absence of sponges and found to be working properly with no change from preimplantation sensitivity. Once sensor testing was concluded, the PVA sponge/tissue samples were prepared for quantitative histological analysis. It was determined that the increase in collagen deposition within the sponge correlated with the decrease in sensor sensitivity. It was also observed that natural angiogenesis (peak at day 14) did not overcome the barrier to glucose diffusion created by the fibrous capsule. Copyright 2007 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 17876777     DOI: 10.1002/jbm.a.31593

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  18 in total

1.  Analyte flux at a biomaterial-tissue interface over time: implications for sensors for type 1 and 2 diabetes mellitus.

Authors:  Neda Rajamand Ekberg; Kerstin Brismar; Jonas Malmstedt; Mari-Anne Hedblad; Ulf Adamson; Urban Ungerstedt; Natalie Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

Review 2.  Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: theoretical framework.

Authors:  Kristen L Helton; Buddy D Ratner; Natalie A Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

3.  Glucose Sensing in the Subcutaneous Tissue: Attempting to Correlate the Immune Response with Continuous Glucose Monitoring Accuracy.

Authors:  Jeffrey I Joseph; Gabriella Eisler; David Diaz; Abdurizzagh Khalf; Channy Loeum; Marc C Torjman
Journal:  Diabetes Technol Ther       Date:  2018-05       Impact factor: 6.118

4.  Nitric Oxide Release for Improving Performance of Implantable Chemical Sensors - A Review.

Authors:  Kyoung Ha Cha; Xuewei Wang; Mark E Meyerhoff
Journal:  Appl Mater Today       Date:  2017-11-09

5.  Factors influencing the effectiveness of glucagon for preventing hypoglycemia.

Authors:  Jessica R Castle; Julia M Engle; Joseph El Youssef; Ryan G Massoud; W Kenneth Ward
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

6.  Increased in vivo glucose recovery via nitric oxide release.

Authors:  Scott P Nichols; Nga N Le; Bruce Klitzman; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2011-01-14       Impact factor: 6.986

7.  Modeling the Physiological Factors Affecting Glucose Sensor Function in Vivo.

Authors:  Matthew T Novak; William M Reichert
Journal:  J Diabetes Sci Technol       Date:  2015-06-30

Review 8.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

9.  Polyelectrolyte-coated alginate microspheres as drug delivery carriers for dexamethasone release.

Authors:  R D Jayant; M J McShane; R Srivastava
Journal:  Drug Deliv       Date:  2009-08       Impact factor: 6.419

Review 10.  Controlled release of biologics for the treatment of type 2 diabetes.

Authors:  Caslin A Gilroy; Kelli M Luginbuhl; Ashutosh Chilkoti
Journal:  J Control Release       Date:  2015-12-02       Impact factor: 9.776

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.