Literature DB >> 17875601

Exposure to alternating electromagnetic fields and effects on the visual and visuomotor systems.

F de Vocht1, L Liket, A De Vocht, T Mistry, P Glover, P Gowland, H Kromhout.   

Abstract

Acute effects on the visual and visuo-motor systems by exposure to electromagnetic fields (EMFs) at a frequency and amplitude similar to those produced by MR imaging gradient coils were assessed. 40 volunteers were exposed in random order to three, time varying, magnetic field gradients (0, 20 and 10 mT m(-1)r.m.s.). The waveform was 50 cycles of a 490 Hz sinusoidal waveform repeated every second with a total duration of 10 min for each trial. The EMFs were generated using an in-house designed and built magnetic gradient coil and waveform generator. During each trial, a test battery assessing the visual sensory (FACT) and visuo-motor (Pursuit Aiming II and visual tracking) neurobehavioral domains was completed by all volunteers. The sequence of these tests was assigned at random for each volunteer. Performance in these tests was analysed using linear mixed effects models adjusted for confounding factors collected in a pre-trial questionnaire. Variability of the estimates was assessed using a delete-1 jack-knife procedure. There was a trend for visuo-motor accuracy to be reduced (p = 0.06) by 1% during high exposure, but not at medium exposure. There was a weaker trend for visual contrast sensitivity to be improved by 12% and 21% during medium and high exposure, respectively, compared with the non-exposed sessions (p = 0.08). These effects did not reach 5% statistical significance within a population of 40 volunteers, but also the magnitude of these effects did not depend on single "extreme" observations.

Entities:  

Mesh:

Year:  2007        PMID: 17875601     DOI: 10.1259/bjr/22263979

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  5 in total

1.  Transient health symptoms of MRI staff working with 1.5 and 3.0 Tesla scanners in the UK.

Authors:  Frank de Vocht; Evridiki Batistatou; Anna Mölter; Hans Kromhout; Kristel Schaap; Martie van Tongeren; Stuart Crozier; Penny Gowland; Stephen Keevil
Journal:  Eur Radiol       Date:  2015-03-13       Impact factor: 5.315

2.  Head tilt in rats during exposure to a high magnetic field.

Authors:  Thomas A Houpt; Jennifer Cassell; Lee Carella; Bryan Neth; James C Smith
Journal:  Physiol Behav       Date:  2011-08-31

Review 3.  Magnetic resonance safety.

Authors:  Steffen Sammet
Journal:  Abdom Radiol (NY)       Date:  2016-03

Review 4.  Occupational exposure to electromagnetic fields in magnetic resonance environment: an update on regulation, exposure assessment techniques, health risk evaluation, and surveillance.

Authors:  Valentina Hartwig; Giorgio Virgili; F Ederica Mattei; Cristiano Biagini; Stefania Romeo; Olga Zeni; Maria Rosaria Scarfì; Rita Massa; Francesco Campanella; Luigi Landini; Fabriziomaria Gobba; Alberto Modenese; Giulio Giovannetti
Journal:  Med Biol Eng Comput       Date:  2021-09-29       Impact factor: 2.602

5.  dB/dt Evaluation in MRI Sites: Is ICNIRP Threshold Limit (for Workers) Exceeded?

Authors:  Giuseppe Acri; Patrizia Inferrera; Lucia Denaro; Carlo Sansotta; Elisa Ruello; Carmelo Anfuso; Francesca Maria Salmeri; Girolamo Garreffa; Giuseppe Vermiglio; Barbara Testagrossa
Journal:  Int J Environ Res Public Health       Date:  2018-06-21       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.