Comparisons of the MacKay-Marg and Tono-Pen applanation tonometers in open and closed in vitro systems were made for the eyes of cats. Both instruments significantly underestimated intraocular pressure (IOP) vs direct manometry (P less than 0.001), but in readily predictable manner, with high coefficients of determination (r2 = 0.99). For tonometer 1 (MacKay-Marg), calculated actual IOP = 1.36 x (MacKay-Marg measurement) - 1.67 mm of Hg; and for tonometer 2 (Tono-Pen), calculated actual IOP = 1.37 x (Tono-Pen measurement) + 0.8 mm of HG, using measurements from 11 enucleated eyes. In vivo comparisons were initially made in 81 clinically normal eyes (n = 41 cats) by applying the Tono-Pen first followed by the MacKay-Marg. Compared with the MacKay-Marg, the Tono-Pen significantly (P less than 0.001) underestimated IOP in these cats. When the order of tonometer applanation was subsequently reversed in 73 clinically normal eyes (n = 37 cats) the Tono-Pen again significantly (P less than 0.001) underestimated IOP, compared with the MacKay-Marg. Alterations in tonometer order did not result in significant differences in measured IOP for the MacKay-Marg when compared with itself, but Tono-Pen measurements were significantly (P less than 0.05) less when its use followed, rather than preceded, that of the MacKay-Marg. Mean (+/- SD) IOP in clinically normal cats when each tonometer was used first was 22.6 +/- 4.0 mm of Hg (range, 14 to 32 mm of Hg) for the MacKay-Marg and 19.7 +/- 5.6 mm of Hg (9 to 31 mm of Hg) for the Tono-Pen.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 1785739

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  12 in total

1.  Retinal intrinsic optical signals in a cat model of primary congenital glaucoma.

Authors:  Jesse B Schallek; Gillian J McLellan; Suresh Viswanathan; Daniel Y Ts'o
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-04-18       Impact factor: 4.799

2.  Secondary acute anterior uveitis with hyphema in a purpose-bred kitten.

Authors:  Melanie S Sorrell; Karen H Taylor; Richard E Fish
Journal:  J Am Assoc Lab Anim Sci       Date:  2008-07       Impact factor: 1.232

Review 3.  Feline glaucoma--a comprehensive review.

Authors:  Gillian J McLellan; Paul E Miller
Journal:  Vet Ophthalmol       Date:  2011-09       Impact factor: 1.644

4.  Effects of topical corticosteroid administration on intraocular pressure in normal and glaucomatous cats.

Authors:  Allyson A Gosling; Julie A Kiland; Lauren E Rutkowski; Adam Hoefs; Norman Matthew Ellinwood; Gillian J McLellan
Journal:  Vet Ophthalmol       Date:  2016-02-15       Impact factor: 1.644

5.  Intraocular pressure measurements in cattle, sheep, and goats with 2 different types of tonometers.

Authors:  Nina Peche; Johanna Corinna Eule
Journal:  Can J Vet Res       Date:  2018-07       Impact factor: 1.310

6.  Validation of the TonoVet® rebound tonometer in normal and glaucomatous cats.

Authors:  Gillian J McLellan; Jeremy P Kemmerling; Julie A Kiland
Journal:  Vet Ophthalmol       Date:  2012-06-06       Impact factor: 1.644

7.  Restrictive orbital myofibroblastic sarcoma in a cat--cross-sectional imaging (MRI & CT) appearance, treatment, and outcome.

Authors:  Sara M Thomasy; Derek D Cissell; Boaz Arzi; Jose G Vilches-Moure; Winnie Y Lo; Erik R Wisner; Richard R Dubielzig; David J Maggs
Journal:  Vet Ophthalmol       Date:  2013-01-03       Impact factor: 1.644

8.  Effect of timolol maleate gel-forming solution on intraocular pressure, pupil diameter, and heart rate in normal and glaucomatous cats.

Authors:  Julie A Kiland; Andrea M Voss; Gillian J McLellan
Journal:  Vet Ophthalmol       Date:  2016-03-18       Impact factor: 1.644

9.  A Comparison of Applanation and Rebound Tonometers in Young Chicks.

Authors:  Lisa A Ostrin; Christine F Wildsoet
Journal:  Curr Eye Res       Date:  2020-07-03       Impact factor: 2.424

10.  Validation and comparison of four handheld tonometers in normal ex vivo canine eyes.

Authors:  Andrea L Minella; Julie A Kiland; Shawna Gloe; Gillian J McLellan
Journal:  Vet Ophthalmol       Date:  2020-06-01       Impact factor: 1.644

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.