Literature DB >> 17854822

Comparison of an electrochemiluminescence assay in plate format over a colorimetric ELISA, for the detection of ricin B chain (RCA-B).

V Guglielmo-Viret1, P Thullier.   

Abstract

An electrochemiluminescence (ECL) assay for the detection of the B chain of ricin (RCA-B) in a 96-well plate format was developed in parallel with a colorimetric ELISA utilizing the same pair of antibodies. Sensitivity results were interpreted with the ANOVA and Tukey statistical tests, allowing a direct comparison between the two technologies, that can probably be extended to other protein antigens such as toxins. Reproducibility, repeatability and rapidity of the two techniques were also compared. The ELISA assay utilized an alkaline phosphatase conjugate for signal generation. After optimization, its limit of detection was 400 pg of RCA-B per ml buffer, with an intra-day standard deviation (SD) of 2.2% of the mean and an inter-day SD of 5.1%. The ECL assay utilized ruthenylated antibodies for detection. The ECL measurement was carried out using a Sector PR 400 plate reader. After optimization, its limit of detection was 50 pg of RCA-B per ml buffer, with an intra-day SD of 4.1% of the mean and an inter-day SD of 4.3%. Starting from a pre-coated plate, the ELISA assay was completed in 7 h and the ECL assay took 2.5 h. While reproducibility and repeatability of the two assays were equivalent, this ECL assay in plate format had an 8-fold better sensitivity for RCA-B detection than the colorimetric ELISA in buffer and in various matrices. The ECL assay was also three times faster, and retained the robustness and convenience of the 96-well plate format.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17854822     DOI: 10.1016/j.jim.2007.08.003

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  13 in total

1.  Fast and sensitive detection of Bacillus anthracis spores by immunoassay.

Authors:  Nathalie Morel; Hervé Volland; Julie Dano; Patricia Lamourette; Patricia Sylvestre; Michèle Mock; Christophe Créminon
Journal:  Appl Environ Microbiol       Date:  2012-07-06       Impact factor: 4.792

2.  An electrochemiluminescence assay for analysis of rabies virus glycoprotein content in rabies vaccines.

Authors:  Todd G Smith; James A Ellison; Xiaoyue Ma; Natalia Kuzmina; William C Carson; Charles E Rupprecht
Journal:  Vaccine       Date:  2013-06-03       Impact factor: 3.641

3.  Carbon nanotubes with enhanced chemiluminescence immunoassay for CCD-based detection of Staphylococcal enterotoxin B in food.

Authors:  Minghui Yang; Yordan Kostov; Hugh A Bruck; Avraham Rasooly
Journal:  Anal Chem       Date:  2008-10-15       Impact factor: 6.986

4.  Synthesis, labeling and bioanalytical applications of a tris(2,2'-bipyridyl)ruthenium(II)-based electrochemiluminescence probe.

Authors:  Xiaoming Zhou; Debin Zhu; Yuhui Liao; Weipeng Liu; Hongxing Liu; Zhaokui Ma; Da Xing
Journal:  Nat Protoc       Date:  2014-04-17       Impact factor: 13.491

5.  Competitive electrochemiluminescence wash and no-wash immunoassays for detection of serum antibodies to smooth Brucella strains.

Authors:  Iain Thompson; John McGiven; Jason Sawyer; Rachel Thirlwall; Nicola Commander; Judy Stack
Journal:  Clin Vaccine Immunol       Date:  2009-03-04

6.  Optimization and validation of a multiplex, electrochemiluminescence-based detection assay for the quantitation of immunoglobulin G serotype-specific antipneumococcal antibodies in human serum.

Authors:  Rocio D Marchese; Derek Puchalski; Pamela Miller; Joseph Antonello; Olivia Hammond; Tina Green; Leonard J Rubinstein; Michael J Caulfield; Daniel Sikkema
Journal:  Clin Vaccine Immunol       Date:  2009-01-21

7.  Association between synovial fluid levels of aggrecan ARGS fragments and radiographic progression in knee osteoarthritis.

Authors:  Staffan Larsson; Martin Englund; André Struglics; L Stefan Lohmander
Journal:  Arthritis Res Ther       Date:  2010-12-31       Impact factor: 5.156

8.  Antibodies against insulin measured by electrochemiluminescence predicts insulitis severity and disease onset in non-obese diabetic mice and can distinguish human type 1 diabetes status.

Authors:  Bernice Lo; Austin D E Swafford; Kimberly A Shafer-Weaver; Lawrence F Jerome; Luba Rakhlin; Douglas R Mathern; Conor A Callahan; Ping Jiang; Lucy J Davison; Helen E Stevens; Carrie L Lucas; Jill White; Reid von Borstel; John A Todd; Michael J Lenardo
Journal:  J Transl Med       Date:  2011-11-28       Impact factor: 5.531

9.  Detection of ricin contamination in ground beef by electrochemiluminescence immunosorbent assay.

Authors:  David L Brandon
Journal:  Toxins (Basel)       Date:  2011-04-04       Impact factor: 4.546

10.  Offloading treatment is linked to activation of proinflammatory cytokines and start of bone repair and remodeling in Charcot arthropathy patients.

Authors:  Agnetha Folestad; Martin Ålund; Susanne Asteberg; Jesper Fowelin; Ylva Aurell; Jan Göthlin; Jean Cassuto
Journal:  J Foot Ankle Res       Date:  2015-12-10       Impact factor: 2.303

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.