Literature DB >> 17846320

Very long-term survival implications of heart valve replacement with tissue versus mechanical prostheses in adults <60 years of age.

Marc Ruel1, Vincent Chan, Pierre Bédard, Alexander Kulik, Ladislaus Ressler, B Khanh Lam, Fraser D Rubens, William Goldstein, Paul J Hendry, Roy G Masters, Thierry G Mesana.   

Abstract

BACKGROUND: Several centers favor replacing a diseased native heart valve with a tissue rather than a mechanical prosthesis, even in younger adult patients. However, long-term data supporting this approach are lacking. We examined the survival implications of selecting a tissue versus a mechanical prosthesis at initial left-heart valve replacement in a cohort of adults <60 years of age who were followed for over 20 years. METHODS AND
RESULTS: Comorbid and procedural data were available from 6554 patients who underwent valve replacement at our institution over the last 35 years. Of these, 1512 patients contributed follow-up data beyond 20 years, of whom 567 were adults <60 years of age at first left-heart valve operation (mean survivor follow-up, 24.0+/-3.1 years). Late outcomes were examined with Cox regression. Valve reoperation, often for prostheses that are no longer commercially available, occurred in 89% and 84% of patients by 20 years after tissue aortic and mitral valve replacement, respectively, and was associated with a mortality of 4.3%. There was no survival difference between patients implanted with a tissue versus a mechanical prosthesis at initial aortic valve replacement (hazard ratio 0.95; 95% CI: 0.7, 1.3; P=0.7). For mitral valve replacement patients, long-term survival was poorer than after aortic valve replacement (hazard ratio 1.4; 95% CI: 1.1, 1.8; P=0.003), but again no detrimental effect was associated with use of a tissue versus a mechanical prosthesis (hazard ratio 0.9; 95% CI 0.5, 1.4; P=0.5).
CONCLUSIONS: In our experience, selecting a tissue prosthesis at initial operation in younger adults does not negatively impact survival into the third decade of follow-up, despite the risk of reoperation.

Entities:  

Mesh:

Year:  2007        PMID: 17846320     DOI: 10.1161/CIRCULATIONAHA.106.681429

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  30 in total

1.  The Ross procedure: an excellent option in the right hands.

Authors:  Michael E Bowdish; S Ram Kumar; Vaughn A Starnes
Journal:  Ann Transl Med       Date:  2016-12

2.  A mechanical heart valve is the best choice.

Authors:  Iqbal H Jaffer; Richard P Whitlock
Journal:  Heart Asia       Date:  2016-04-28

Review 3.  Bioprosthetic heart valves of the future.

Authors:  Rizwan A Manji; Burcin Ekser; Alan H Menkis; David K C Cooper
Journal:  Xenotransplantation       Date:  2014-01-21       Impact factor: 3.907

4.  Choice of prosthetic heart valve in a developing country.

Authors:  Shiv Kumar Choudhary; Sachin Talwar; Balram Airan
Journal:  Heart Asia       Date:  2016-04-28

5.  A systematic review and meta-analysis of mechanical vs biological composite aortic root replacement, early and 1-year results.

Authors:  Mohamad Bashir; Amer Harky; Saied Froghi; Benjamin Adams; Megan Garner; Prity Gupta; Aung Oo; Rakesh Uppal
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-10-10

Review 6.  Transcatheter Valve Replacement: Risk Levels and Contemporary Outcomes.

Authors:  Manuel Reyes; Michael J Reardon
Journal:  Methodist Debakey Cardiovasc J       Date:  2017 Jul-Sep

7.  Effect of Arched Leaflets and Stent Profile on the Hemodynamics of Tri-Leaflet Flexible Polymeric Heart Valves.

Authors:  Atieh Yousefi; David L Bark; Lakshmi P Dasi
Journal:  Ann Biomed Eng       Date:  2016-06-15       Impact factor: 3.934

Review 8.  Current status and future perspectives of prosthetic valve selection for aortic valve replacement.

Authors:  Hiroshi Furukawa; Kazuo Tanemoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-05-31

9.  Mid- to long-term outcome comparison of the Medtronic Hancock II and bi-leaflet mechanical aortic valve replacement in patients younger than 60 years of age: a propensity-matched analysis.

Authors:  Yin Wang; Si Chen; Jiawei Shi; Geng Li; Nianguo Dong
Journal:  Interact Cardiovasc Thorac Surg       Date:  2015-12-15

Review 10.  Transcatheter Aortic Valve-in-Valve Procedure in Patients with Bioprosthetic Structural Valve Deterioration.

Authors:  Ross M Reul; Mahesh K Ramchandani; Michael J Reardon
Journal:  Methodist Debakey Cardiovasc J       Date:  2017 Jul-Sep