Literature DB >> 1781880

The dimensional accuracy of 12 impression material and die stone combinations.

R B Price1, J D Gerrow, E J Sutow, R MacSween.   

Abstract

This study determined the dimensional accuracy of dies made using a combination of four impression materials and three Type IV die stones. A metal die was prepared for a molar complete cast crown, and 10 stone replicas were made using 12 different combinations of impression materials and die stones. The distances between reference points on the metal and stone dies were measured in three directions with a traveling microscope. Analysis of variance and Duncan's MR comparisons (P less than or equal to .05) showed that all of the stone dies were larger than the metal die. Although there were significant differences between some of the impression material/die stone combinations, all of the stone dies were measured to be within 9 microns of each other. No one impression material/die stone combination consistently produced the smallest or largest die in the three measured directions.

Mesh:

Substances:

Year:  1991        PMID: 1781880

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  5 in total

1.  A Comparative Evaluation of the Linear Dimensional Accuracy of Four Impression Techniques using Polyether Impression Material.

Authors:  Smita Sara Manoj; K P Cherian; Vidya Chitre; Meena Aras
Journal:  J Indian Prosthodont Soc       Date:  2013-02-06

2.  Marginal and internal fit of feldspathic ceramic CAD/CAM crowns fabricated via different extraoral digitization methods: a micro-computed tomography analysis.

Authors:  Ece İrem Oğuz; Mehmet Ali Kılıçarslan; Mert Ocak; Burak Bilecenoğlu; Zeynep Ekici
Journal:  Odontology       Date:  2020-10-26       Impact factor: 2.634

3.  Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition.

Authors:  Ye-Kyu Rhee; Yoon-Hyuk Huh; Lee-Ra Cho; Chan-Jin Park
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

4.  Analysis of the Mechanical Behavior and Surface Rugosity of Different Dental Die Materials.

Authors:  Ciro T Niekawa; Simone Kreve; Gisseli Bertozzi A'vila; Gilmar Gil Godoy; J R Eduardo Vieira da Silva; Sergio Candido Dias
Journal:  J Int Soc Prev Community Dent       Date:  2017-02-21

5.  Quantitative analysis on the wear of monolithic zirconia crowns on antagonist teeth.

Authors:  Zhenyu Tang; Xinyi Zhao; Hui Wang
Journal:  BMC Oral Health       Date:  2021-03-04       Impact factor: 2.757

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.