Retrieval analyses of highly cross-linked polyethylene acetabular liners four and five years after implantation.

K Knahr1, M Pospischill, P Köttig, W Schneider, H Plenk.   

Abstract

Two Durasul highly crosslinked polyethylene liners were exchanged during revision surgery four and five years after implantation, respectively. The retrieved liners were evaluated macroscopically and surface analysis was performed using optical and electron microscopy. A sample of each liner was used to determine the oxidation of the material by Fourier transform infrared spectroscopy. Samples of the capsule were examined histologically. The annual wear rate was found to be 0.010 and 0.015 mm/year, respectively. Surface analysis showed very little loss of material caused by wear. Histological evaluation revealed a continuous neosynovial lining with single multinucleated foreign-body giant cells. Our findings showed no unexpected patterns of wear on the articulating surfaces up to five years after implantation and no obvious failure of material.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17785741     DOI: 10.1302/0301-620X.89B8.18809

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  5 in total

1.  Wear testing and particle characterisation of sequentially crosslinked polyethylene acetabular liners using different femoral head sizes.

Authors:  Carmen Zietz; Christian Fabry; Lars Middelborg; Gerhard Fulda; Wolfram Mittelmeier; Rainer Bader
Journal:  J Mater Sci Mater Med       Date:  2013-04-25       Impact factor: 3.896

2.  Do tissues from THA revision of highly crosslinked UHMWPE liners contain wear debris and associated inflammation?

Authors:  Ryan M Baxter; Theresa A Freeman; Steven M Kurtz; Marla J Steinbeck
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

3.  Distinct immunohistomorphologic changes in periprosthetic hip tissues from historical and highly crosslinked UHMWPE implant retrievals.

Authors:  Ryan M Baxter; Allyson Ianuzzi; Theresa A Freeman; Steven M Kurtz; Marla J Steinbeck
Journal:  J Biomed Mater Res A       Date:  2010-10       Impact factor: 4.396

4.  Backside Wear Analysis of Retrieved Acetabular Liners with a Press-Fit Locking Mechanism in Comparison to Wear Simulation In Vitro.

Authors:  Ana Laura Puente Reyna; Marcus Jäger; Thilo Floerkemeier; Sven Frecher; Karl-Stefan Delank; Christoph Schilling; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2016-09-19       Impact factor: 3.411

5.  UHMWPE for arthroplasty: past or future?

Authors:  Elena Maria Brach Del Prever; Alessandro Bistolfi; Pierangiola Bracco; Luigi Costa
Journal:  J Orthop Traumatol       Date:  2008-12-24
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.