Literature DB >> 17763347

Contrast agent concentration measurements affecting quantification of bolus-tracking perfusion MRI.

Fernando Calamante1, Evert-jan P A Vonken, Matthias J P van Osch.   

Abstract

Measurement of the concentration of the contrast agent using dynamic susceptibility contrast MRI relies on field inhomogeneities caused by the presence of the paramagnetic agent. The usual method for calculation of the concentration from dynamic T2*-weighted images is based on two key assumptions: 1) a linear relation between the change in R2* and the contrast agent concentration, and 2) a negligible effect on the MR signal due to concurrent T1 changes. In this study the effect of inaccuracies in these two assumptions on perfusion measurements was investigated using simulations and in vivo data. The results of the simulations provide a quantitative characterization of the magnitude of these effects for various experimental conditions (e.g., when a 1-sec TR is used with TE=20 ms, the T1 effects can introduce up to 40% cerebral blood flow underestimation depending on the flip angle). These findings can be used as a guide to estimate the errors in specific practical implementations, as well as to optimize the sequence parameters to minimize their effect. In summary, this study shows that the arterial input function measurement should be corrected for nonlinear R2* effects and that care should be taken in the study design to avoid introducing significant T1 effects in perfusion quantification. Copyright (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17763347     DOI: 10.1002/mrm.21362

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  29 in total

1.  Increasing temporal resolution of DSC perfusion MRI using the analytic image concept.

Authors:  Josiane Yankam Njiwa; David Ratering; Christof Baltes; Markus Rudin
Journal:  MAGMA       Date:  2010-08-07       Impact factor: 2.310

Review 2.  Real-time diffusion-perfusion mismatch analysis in acute stroke.

Authors:  Matus Straka; Gregory W Albers; Roland Bammer
Journal:  J Magn Reson Imaging       Date:  2010-11       Impact factor: 4.813

3.  ASFNR recommendations for clinical performance of MR dynamic susceptibility contrast perfusion imaging of the brain.

Authors:  K Welker; J Boxerman; A Kalnin; T Kaufmann; M Shiroishi; M Wintermark
Journal:  AJNR Am J Neuroradiol       Date:  2015-04-23       Impact factor: 3.825

4.  A fully automated method for quantitative cerebral hemodynamic analysis using DSC-MRI.

Authors:  Atle Bjørnerud; Kyrre E Emblem
Journal:  J Cereb Blood Flow Metab       Date:  2010-01-20       Impact factor: 6.200

Review 5.  Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities.

Authors:  Linda Knutsson; Freddy Ståhlberg; Ronnie Wirestam
Journal:  MAGMA       Date:  2009-12-04       Impact factor: 2.310

6.  Precision analysis of kinetic modelling estimates in dynamic contrast enhanced MRI.

Authors:  Dieter De Naeyer; Yves De Deene; Wim P Ceelen; Patrick Segers; Pascal Verdonck
Journal:  MAGMA       Date:  2011-01-08       Impact factor: 2.310

7.  Diagnostic accuracy of dynamic contrast-enhanced MR imaging using a phase-derived vascular input function in the preoperative grading of gliomas.

Authors:  T B Nguyen; G O Cron; J F Mercier; C Foottit; C H Torres; S Chakraborty; J Woulfe; G H Jansen; J M Caudrelier; J Sinclair; M J Hogan; R E Thornhill; I G Cameron
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-22       Impact factor: 3.825

8.  Simultaneous perfusion and permeability measurements using combined spin- and gradient-echo MRI.

Authors:  Heiko Schmiedeskamp; Jalal B Andre; Matus Straka; Thomas Christen; Seema Nagpal; Lawrence Recht; Reena P Thomas; Greg Zaharchuk; Roland Bammer
Journal:  J Cereb Blood Flow Metab       Date:  2013-03-06       Impact factor: 6.200

9.  Dynamic susceptibility contrast MRI with localized arterial input functions.

Authors:  John J Lee; G Larry Bretthorst; Colin P Derdeyn; William J Powers; Tom O Videen; Abraham Z Snyder; Joanne Markham; Joshua S Shimony
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

10.  Influence of blood/tissue differences in contrast agent relaxivity on tracer-based MR perfusion measurements.

Authors:  Arvid Morell; Fredrik Lennmyr; Ove Jonsson; Thomas Tovedal; Jean Pettersson; Jonas Bergquist; Vitas Zemgulis; Gunnar Myrdal Einarsson; Stefan Thelin; Håkan Ahlström; Atle Bjørnerud
Journal:  MAGMA       Date:  2014-06-28       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.