Literature DB >> 17761505

Impact of late incomplete stent apposition after sirolimus-eluting stent implantation on 4-year clinical events: intravascular ultrasound analysis from the multicentre, randomised, RAVEL, E-SIRIUS and SIRIUS trials.

R Hoffmann1, M-C Morice, J W Moses, P J Fitzgerald, L Mauri, G Breithardt, J Schofer, P W Serruys, H-P Stoll, M B Leon.   

Abstract

BACKGROUND: The impact of incomplete stent apposition (ISA) after drug-eluting stent implantation determined by intravascular ultrasound (IVUS) on late clinical events is not well defined.
OBJECTIVE: To evaluate the clinical impact of ISA after sirolimus-eluting stent (SES) placement during a follow-up period of 4 years.
DESIGN: Pooled analysis from the RAVEL, E-SIRIUS and SIRIUS trials, three randomised, multicentre studies comparing SES and bare-metal stents (BMS).
METHODS: IVUS at angiographic follow-up was available in 325 patients (SES: n = 180, BMS: n = 145). IVUS images were reviewed for the presence of ISA defined as one or more unapposed stent struts. Clinical follow-up was available for a 4-year period in all patients. Frequency, predictors and clinical sequel of ISA at follow-up after SES and BMS implantation were determined.
RESULTS: ISA at follow-up was more common after SES (n = 45 (25%)) than after BMS (n = 12 (8.3%), p<0.001). Canadian Cardiology Society class III or IV angina at stent implantation (odds ratio (OR) = 4.69, 95% CI 2.15 to 10.23, p<0.001) and absence of diabetes (OR = 3.42, 95% CI 1.05 to 11.1, p = 0.041) were predictors of ISA at follow-up after SES placement. Rate of myocardial infarction tended to be slightly higher for ISA than for non-ISA patients. When SES patients only were considered, major adverse cardiac event free survival at 4 years was identical for those with and without ISA at follow-up (11.1% vs 16.3%, p = 0.48).
CONCLUSIONS: ISA at follow-up is more common after SES implantation than after BMS implantation. Considering the current very sensitive IVUS definition, ISA appears to be an IVUS finding without significant impact on the incidence of major adverse cardiac events even during long-term follow-up.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17761505     DOI: 10.1136/hrt.2007.120154

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  8 in total

Review 1.  Applications of grayscale and radiofrequency intravascular ultrasound to image atherosclerotic plaque.

Authors:  Somjot S Brar; Gary S Mintz; Akiko Maehara; Gregg W Stone
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

2.  Parent vessel size and curvature strongly influence risk of incomplete stent apposition in enterprise intracranial aneurysm stent coiling.

Authors:  R S Heller; A M Malek
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-04       Impact factor: 3.825

Review 3.  Causes, assessment, and treatment of stent thrombosis--intravascular imaging insights.

Authors:  Daniel S Ong; Ik-Kyung Jang
Journal:  Nat Rev Cardiol       Date:  2015-03-17       Impact factor: 32.419

4.  Extensive late-acquired incomplete stent apposition after sirolimus-eluting stent implantation.

Authors:  Hyun-Chul Choi; Seung-Ho Hur; Chang-Wook Nam; Yun-Kyeong Cho; Hyungseop Kim; Nam-Hee Park; Yoon-Nyun Kim; Kwon-Bae Kim
Journal:  Korean Circ J       Date:  2010-01-27       Impact factor: 3.243

5.  Assessment of the relation between IVUS measurements and clinical outcome in elderly patients after sirolimus-eluting stent implantation for de novo coronary lesions.

Authors:  Run Du; Rui Yan Zhang; Qi Zhang; Yu Hang Shi; Jian Hu; Zhen Kun Yang; Feng Hua Ding; Jian Sheng Zhang; Wei Feng Shen
Journal:  Int J Cardiovasc Imaging       Date:  2012-01-06       Impact factor: 2.357

6.  IVUS-Guided Stent Implantation to Improve Outcome: A Promise Waiting to be Fulfilled.

Authors:  Renata Rogacka; Azeem Latib; Antonio Colombo
Journal:  Curr Cardiol Rev       Date:  2009-05

7.  Expert review document part 2: methodology, terminology and clinical applications of optical coherence tomography for the assessment of interventional procedures.

Authors:  Francesco Prati; Giulio Guagliumi; Gary S Mintz; Marco Costa; Evelyn Regar; Takashi Akasaka; Peter Barlis; Guillermo J Tearney; Ik-Kyung Jang; Elosia Arbustini; Hiram G Bezerra; Yukio Ozaki; Nico Bruining; Darius Dudek; Maria Radu; Andrejs Erglis; Pascale Motreff; Fernando Alfonso; Kostas Toutouzas; Nieves Gonzalo; Corrado Tamburino; Tom Adriaenssens; Fausto Pinto; Patrick W J Serruys; Carlo Di Mario
Journal:  Eur Heart J       Date:  2012-05-31       Impact factor: 29.983

8.  Coronary aneurysm occurring late after drug-eluting stent implantation.

Authors:  Etan Abergel; Ariel Roguin
Journal:  ISRN Cardiol       Date:  2011-05-11
  8 in total