Literature DB >> 17729404

Capsule endoscopy: current status in obscure gastrointestinal bleeding.

R Gupta1, Duvvuru Nageshwar Reddy.   

Abstract

Capsule endoscopy (CE) is a safe, non invasive diagnostic modality for the evaluation of small bowel lesions. Obscure gastrointestinal bleeding (OGIB) is one of the most important indications of capsule endoscopy. Capsule endoscopy has a very high diagnostic yield especially if the bleeding is ongoing. This technique appears to be superior to other techniques for the detection of suspected lesions and the source of bleeding. Capsule endoscopy has been shown to change the outcome in patients with obscure gastrointestinal (GI) bleed.

Entities:  

Mesh:

Year:  2007        PMID: 17729404      PMCID: PMC4611825          DOI: 10.3748/wjg.v13.i34.4551

Source DB:  PubMed          Journal:  World J Gastroenterol        ISSN: 1007-9327            Impact factor:   5.742


  20 in total

1.  The role of wireless capsule endoscopy in investigating unexplained iron deficiency anemia after negative endoscopic evaluation of the upper and lower gastrointestinal tract.

Authors:  P Apostolopoulos; C Liatsos; I M Gralnek; E Giannakoulopoulou; G Alexandrakis; C Kalantzis; P Gabriel; N Kalantzis
Journal:  Endoscopy       Date:  2006-11       Impact factor: 10.093

2.  Capsule endoscopy in obscure gastrointestinal bleeding--an Indian experience.

Authors:  Rajesh Gupta; Sandeep Lakhtakia; Manu Tandan; Rupa Banerjee; Mohan Ramchandani; S Anuradha; C Ramji; G V Rao; R Pradeep; D Nageshwar Reddy
Journal:  Indian J Gastroenterol       Date:  2006 Jul-Aug

3.  How much helpful is the capsule endoscopy for the diagnosis of small bowel lesions?

Authors:  Osman Ersoy; Bulent Sivri; Serap Arslan; Figen Batman; Yusuf Bayraktar
Journal:  World J Gastroenterol       Date:  2006-06-28       Impact factor: 5.742

4.  Jejunal diverticulosis diagnosed by double-balloon enteroscopy.

Authors:  Ahmad Kamal; Lauren B Gerson
Journal:  Gastrointest Endosc       Date:  2006-05       Impact factor: 9.427

5.  A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with obscure gastrointestinal bleeding.

Authors:  Stuart L Triester; Jonathan A Leighton; Grigoris I Leontiadis; David E Fleischer; Amy K Hara; Russell I Heigh; Arthur D Shiff; Virender K Sharma
Journal:  Am J Gastroenterol       Date:  2005-11       Impact factor: 10.864

6.  What is the learning curve associated with double-balloon enteroscopy? Technical details and early experience in 6 U.S. tertiary care centers.

Authors:  Shahab Mehdizadeh; Andrew Ross; Lauren Gerson; Jonathan Leighton; Ann Chen; Drew Schembre; Gary Chen; Carol Semrad; Ahmad Kamal; Edwyn M Harrison; Kenneth Binmoeller; Irving Waxman; Richard Kozarek; Simon K Lo
Journal:  Gastrointest Endosc       Date:  2006-11       Impact factor: 9.427

7.  A prospective two-center study comparing wireless capsule endoscopy with intraoperative enteroscopy in patients with obscure GI bleeding.

Authors:  Dirk Hartmann; Harald Schmidt; Georg Bolz; Dieter Schilling; Frank Kinzel; Axel Eickhoff; Winfried Huschner; Kathleen Möller; Ralf Jakobs; Peter Reitzig; Uwe Weickert; Klaus Gellert; Harald Schultz; Klaus Guenther; Hartmut Hollerbuhl; Klaus Schoenleben; Hans-Joachim Schulz; Juergen F Riemann
Journal:  Gastrointest Endosc       Date:  2005-06       Impact factor: 9.427

8.  Yield of repeat wireless video capsule endoscopy in patients with obscure gastrointestinal bleeding.

Authors:  Bradford H Jones; David E Fleischer; Virender K Sharma; Russell I Heigh; Arthur D Shiff; Jose L Hernandez; Jonathan A Leighton
Journal:  Am J Gastroenterol       Date:  2005-05       Impact factor: 10.864

9.  Diagnostic yield and clinical outcomes of capsule endoscopy.

Authors:  Amit Rastogi; Robert E Schoen; Adam Slivka
Journal:  Gastrointest Endosc       Date:  2004-12       Impact factor: 9.427

10.  Small bowel: preliminary comparison of capsule endoscopy with barium study and CT.

Authors:  Amy K Hara; Jonathan A Leighton; Virender K Sharma; David E Fleischer
Journal:  Radiology       Date:  2003-11-14       Impact factor: 11.105

View more
  4 in total

1.  An intelligent electronic capsule system for automated detection of gastrointestinal bleeding.

Authors:  Hong-ying Liu; Gang Wang; Kang Wei; Xi-tian Pi; Lan Zhu; Xiao-lin Zheng; Zhi-yu Wen
Journal:  J Zhejiang Univ Sci B       Date:  2010-12       Impact factor: 3.066

2.  The effect of metoclopramide in capsule enteroscopy.

Authors:  Nuno Almeida; Pedro Figueiredo; Paulo Freire; Sandra Lopes; Clotilde Lérias; Hermano Gouveia; Maximino Correia Leitão
Journal:  Dig Dis Sci       Date:  2009-01-29       Impact factor: 3.199

Review 3.  A guide to diagnosis of iron deficiency and iron deficiency anemia in digestive diseases.

Authors:  Fernando Bermejo; Santiago García-López
Journal:  World J Gastroenterol       Date:  2009-10-07       Impact factor: 5.742

4.  Outcome of endoscopy-negative iron deficiency anemia in patients above 65: A longitudinal multicenter cohort.

Authors:  Raphaël Clere-Jehl; Erik Sauleau; Stefan Ciuca; Mickael Schaeffer; Amanda Lopes; Bernard Goichot; Thomas Vogel; Georges Kaltenbach; Eric Bouvard; Jean-Louis Pasquali; Daniel Sereni; Emmanuel Andres; Anne Bourgarit
Journal:  Medicine (Baltimore)       Date:  2016-11       Impact factor: 1.889

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.