Literature DB >> 17729364

Maximizing contrast-to-noise ratio in ultra-high resolution peripheral MR angiography using a blood pool agent and parallel imaging.

Maisie S Wang1, David R Haynor, Gregory J Wilson, Tim Leiner, Jeffrey H Maki.   

Abstract

PURPOSE: To determine sequence parameters that maximize vascular contrast-to-noise (CNR) for ultra-high resolution equilibrium phase (EP) peripheral imaging for the blood pool agent (BPA) Vasovist.
MATERIALS AND METHODS: A model for maximizing CNR in EP MR angiography (MRA) is presented. Tissue relaxation times, coil geometry (g)-factors, and clinical imaging requirements (voxel volume and scan time) were determined from human studies. Using these known values, parameters for TR, TE, bandwidth, flip angle (FA), and sensitivity encoding (SENSE) factor that maximized CNR were derived from the model. CNR was enhanced by using reduction in scan time gained from parallel imaging to increase TR and minimize bandwidth. A total of 10 patients were imaged using model-derived EP CE-MRA parameters.
RESULTS: The model closely predicted experimental CNR data measured in two clinical studies (r(2) = 0.85) and demonstrated an increase in CNR by a factor of 2.3 when subjects were imaged using optimal sequence parameters (P < 0.001). Thigh and calf data were acquired with voxel volumes on the order of 0.2 mm(3) using a SENSE factor of 4.
CONCLUSION: Recommended imaging parameters for a 12-channel and 18-channel peripheral vascular coil at two doses of Vasovist (0.03 mmol/kg and 0.05 mmol/kg) are presented. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17729364     DOI: 10.1002/jmri.20998

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

1.  Intravascular contrast agent T1 shortening: fast T1 relaxometry in a carotid volunteer study.

Authors:  Michael Bock; Jessica Schulz; Stefan Ueltzhoeffer; Frederik Giesel; Matthias Voth; Marco Essig
Journal:  MAGMA       Date:  2008-08-29       Impact factor: 2.310

Review 2.  Point/counterpoint: dose-related issues in cardiac CT imaging.

Authors:  Beverley Newman; Shreyas S Vasanawala
Journal:  Pediatr Radiol       Date:  2011-08-17

3.  Rapid MR venography in children using a blood pool contrast agent and multi-station fat-water-separated volumetric imaging.

Authors:  Pejman Ghanouni; Shannon G Walters; Shreyas S Vasanawala
Journal:  Pediatr Radiol       Date:  2011-10-12

Review 4.  Contrast enhanced pulmonary magnetic resonance angiography for pulmonary embolism: Building a successful program.

Authors:  Scott K Nagle; Mark L Schiebler; Michael D Repplinger; Christopher J François; Karl K Vigen; Rajkumar Yarlagadda; Thomas M Grist; Scott B Reeder
Journal:  Eur J Radiol       Date:  2015-12-29       Impact factor: 3.528

5.  Equilibrium-phase high spatial resolution contrast-enhanced MR angiography at 1.5T in preoperative imaging for perforator flap breast reconstruction.

Authors:  Bas Versluis; Stefania Tuinder; Carla Boetes; René Van Der Hulst; Arno Lataster; Tom Van Mulken; Joachim Wildberger; Michiel de Haan; Tim Leiner
Journal:  PLoS One       Date:  2013-08-29       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.