Literature DB >> 17723779

Determination of tryptophan and histidine by adsorptive cathodic stripping voltammetry using H-point standard addition method.

Ali A Ensafi1, R Hajian.   

Abstract

A sequential method is proposed for the determination of tryptophane and histidine by adsorptive cathodic stripping voltammetry using standard addition and H-point standard addition method (HPSAM). The complexes of copper(II) with the amino acids were accumulated onto the surface of a hanging mercury drop electrode for 60s. Then the preconcentrated complexes were reduced by square wave voltammetry and the peak currents were measured. The effect of various parameters such as pH, concentration of copper, accumulation potential, accumulation time and scan rate on the sensitivity were studied by one-at-a time and artificial neural network. Under the optimized conditions, the peak currents at about +0.05 to -0.30 V is proportional to the concentration of tryptophan and histidine over the concentration ranges of 5-220 and 100-1200 nM, respectively. Optimization of the parameters by one-at-a time showed that at accumulation potential of 0.10 V (versus Ag/AgCl reference electrode) the peak current is proportional only to the concentration of tryptophan and histidine does not have any contribution to the current. The optimization results by artificial neural network showed that at accumulation potential of -0.06 V (versus Ag/AgCl) the peak current is proportional to the both concentrations of tryptophan and histidine. Therefore, the method of H-point standard addition has been used for resolving overlap voltamograms for determination of histidine in the present of tryptophane. The method was successfully applied to the determination of tryptophan and histidine in synthetic and real samples.

Entities:  

Year:  2006        PMID: 17723779     DOI: 10.1016/j.aca.2006.07.076

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

Review 1.  A Review of Sensors and Biosensors Modified with Conducting Polymers and Molecularly Imprinted Polymers Used in Electrochemical Detection of Amino Acids: Phenylalanine, Tyrosine, and Tryptophan.

Authors:  Ancuța Dinu; Constantin Apetrei
Journal:  Int J Mol Sci       Date:  2022-01-22       Impact factor: 5.923

2.  Electrochemical Sensor for Tryptophan Determination Based on Copper-cobalt Hexacyanoferrate Film Modified Graphite Electrode.

Authors:  Yingju Liu; Li Xu
Journal:  Sensors (Basel)       Date:  2007-10-19       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.