Literature DB >> 17723589

A comparison of boron-doped diamond thin-film and Hg-coated glassy carbon electrodes for anodic stripping voltammetric determination of heavy metal ions in aqueous media.

Elizabeth A McGaw1, Greg M Swain.   

Abstract

The performance of boron-doped diamond (BDD) for the anodic stripping voltammetric (ASV) determination of heavy metal ions (Zn2+, Cd2+, Pb2+, Cu2+, Ag+) was compared with that of Hg-coated glassy carbon (Hg-GC). Hg has historically been the electrode of choice for ASV but there is an ongoing search for alternate electrodes and diamond is one of these. Despite the fundamentally different nature of the metal reduction and oxidation reactions on these two electrodes, BDD provides as good or superior analytical detection figures of merit when compared to Hg. The stripping peak potentials for all the metals studied were similar at both electrodes indicating that BDD is as active as Hg for metal phase formation and oxidation. Due to the more heterogeneous chemical and electrical properties across the BDD surface, the stripping peaks were broader and more asymmetric than they were for Hg-GC. The linear dynamic range for BDD was three to four orders of magnitude (r2>0.995), similar to Hg-GC, but the sensitivity for BDD was three to five times lower. However, the lower background current and noise for BDD enabled detection limits as low as those seen for Hg-GC. The minimum concentration of each metal ion detectable (S/N> or =3) with BDD was in the mid to low ppb range (e.g., 50 ppb Zn2+, 1.0 ppb Cd2+, 5.0 ppb Pb2+, 10 ppb Cu2+ and 1.0 ppb Ag+). BDD exhibited an electrode-to-electrode and run-to-run variability of less than 5%, which is comparable to that for Hg-GC. The possibility of incomplete metal oxidation and metal phase detachment from BDD was investigated using double step chronoamperometry. Neither of these processes was found to occur to any appreciable extent. The results demonstrate that BDD is a viable alternate electrode to Hg for ASV.

Entities:  

Year:  2006        PMID: 17723589     DOI: 10.1016/j.aca.2006.05.094

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  7 in total

1.  Polymer-grafted QCM chemical sensor and application to heavy metalions real time detection.

Authors:  Luciana Sartore; Marzia Barbaglio; Laura Borgese; Elza Bontempi
Journal:  Sens Actuators B Chem       Date:  2011-07-20       Impact factor: 7.460

2.  Equilibrium and kinetic behavior of Fe(CN)6(3-/4-) and cytochrome c in direct electrochemistry using a film electrode thin-layer transmission cell.

Authors:  Yingrui Dai; Yi Zheng; Greg M Swain; Denis A Proshlyakov
Journal:  Anal Chem       Date:  2010-12-17       Impact factor: 6.986

3.  Individual and simultaneous determination of lead, cadmium, and zinc by anodic stripping voltammetry at a bismuth bulk electrode.

Authors:  Kristie C Armstrong; Clarissa E Tatum; Royce N Dansby-Sparks; James Q Chambers; Zi-Ling Xue
Journal:  Talanta       Date:  2010-05-20       Impact factor: 6.057

4.  Highly sensitive detection of urinary cadmium to assess personal exposure.

Authors:  Avni A Argun; Ashley M Banks; Gwendolynne Merlen; Linda A Tempelman; Michael F Becker; Thomas Schuelke; Badawi M Dweik
Journal:  Anal Chim Acta       Date:  2013-03-01       Impact factor: 6.558

5.  Metallo-graphene nanocomposite electrocatalytic platform for the determination of toxic metal ions.

Authors:  Chandre M Willemse; Khotso Tlhomelang; Nazeem Jahed; Priscilla G Baker; Emmanuel I Iwuoha
Journal:  Sensors (Basel)       Date:  2011-04-01       Impact factor: 3.576

Review 6.  Modified electrodes used for electrochemical detection of metal ions in environmental analysis.

Authors:  Gregory March; Tuan Dung Nguyen; Benoit Piro
Journal:  Biosensors (Basel)       Date:  2015-04-29

7.  Electrochemical Sensing toward Trace As(III) Based on Mesoporous MnFe₂O₄/Au Hybrid Nanospheres Modified Glass Carbon Electrode.

Authors:  Shaofeng Zhou; Xiaojuan Han; Honglei Fan; Yaqing Liu
Journal:  Sensors (Basel)       Date:  2016-06-22       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.