Optical bio-sniffer for methyl mercaptan in halitosis.

Kohji Mitsubayashi1, Takeshi Minamide, Kimio Otsuka, Hiroyuki Kudo, Hirokazu Saito.   

Abstract

An optical bio-sniffer for methyl mercaptan (MM) one of major odorous chemicals in halitosis (bad breath) was constructed by immobilizing monoamine oxidase type A (MAO-A) onto a tip of a fiber optic oxygen sensor (od: 1.59 mm) with an oxygen sensitive ruthenium organic complex (excitation: 470 nm, fluorescent: 600 nm). A flow cell for circulating buffer solution was applied to rinse and clean the tip of the device like nasal mucosa. In order to amplify the bio-sniffer output, a substrate regeneration cycle caused by coupling MAO-A with l-ascorbic acid (AsA) as reducing reaction with reagent system was applied to the sensor system. After evaluating the sensor characteristics using a gas flow measurement system with a gas generator, the optical bio-sniffer was applied to expired gases from healthy male volunteers for halitosis analysis as a physiological application. The optical bio-sniffer was applied to detect the oxygen consumption induced by MAO-A enzymatic reaction (and AsA chemical reduction) with gaseous MM application. The bio-sniffer was calibrated against MM vapor from 8.7 to 11500 ppb with correlation coefficient of 0.977, including a MM threshold (200 ppb) of pathologic halitosis and the human sense of smell level 3.5 (10.0 ppb), with good gas-selectivity based on the MAO-A substrate specificity. As the result of the physiological application, the optical bio-sniffer could successfully monitor the MM level change in breath samples during daytime, which is consistent with the previously reported results.

Entities:  

Year:  2006        PMID: 17723508     DOI: 10.1016/j.aca.2006.01.062

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Halitosis: a new definition and classification.

Authors:  M Aydin; C N Harvey-Woodworth
Journal:  Br Dent J       Date:  2014-07-11       Impact factor: 1.626

2.  ZnO Nanorods Coated Single-Mode-Multimode-Single-Mode Optical Fiber Sensor for VOC Biomarker Detection.

Authors:  Kankan Swargiary; Prattakorn Metem; Chayapol Kulatumyotin; Suphavit Thaneerat; Noppasin Ajchareeyasoontorn; Pannathorn Jitpratak; Tanujjal Bora; Waleed S Mohammed; Joydeep Dutta; Charusluk Viphavakit
Journal:  Sensors (Basel)       Date:  2022-08-20       Impact factor: 3.847

3.  Optimization of hydrogen peroxide detection for a methyl mercaptan biosensor.

Authors:  Zhan-Hong Li; Houssemeddine Guedri; Bruno Viguier; Shi-Gang Sun; Jean-Louis Marty
Journal:  Sensors (Basel)       Date:  2013-04-15       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.