Literature DB >> 17720071

Visual and optical performance of the Akreos Adapt Advanced Optics and Tecnis Z9000 intraocular lenses: Swedish multicenter study.

Björn Johansson1, Staffan Sundelin, Anna Wikberg-Matsson, Peter Unsbo, Anders Behndig.   

Abstract

PURPOSE: To compare the subjective visual and objective optical performance of 2 aspherical intraocular lenses (IOLs), the Akreos Adapt Advanced Optics (AO) (Bausch & Lomb, Inc.) and the Tecnis Z9000 (Advanced Medical Optics, Inc.).
SETTING: Four university hospitals in Sweden.
METHODS: This study comprised 80 patients, 20 each from 4 university hospital centers in Sweden. All patients had bilateral clear corneal phacoemulsification with implantation of an Akreos Adapt AO IOL in 1 eye and Tecnis Z9000 IOL in the other eye according to a randomization protocol. Preoperatively, 90% contrast Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity was measured and the mesopic pupil sizes were determined. Ten to 12 weeks postoperatively, 12.5% and 90% contrast ETDRS visual acuities and photopic and mesopic Functional Acuity Contrast Test chart contrast sensitivities were determined. Wavefront analysis was performed with the Zywave II aberrometer (Bausch & Lomb, Inc.), and a questionnaire on the subjective quality of vision was completed by each patient.
RESULTS: The Akreos AO IOL and Tecnis Z9000 IOL produced similar high- and low-contrast visual acuities as well as photopic and mesopic contrast sensitivities. The Tecnis Z9000 IOL resulted in lower spherical aberrations of the eye (mean 0.05 +/- 0.13 microm versus 0.35 +/- 0.13 microm root mean square, 6.0 mm pupil) (P<.001); however, the Akreos AO IOL provided a larger depth of field (mean 1.22 diopter [D] +/- 0.48 [SD] versus 0.86 +/- 0.50 D, 6.0 mm pupil) (P<.001). Patient satisfaction was generally high, although 68.8% of the patients reported some type of visual disturbance postoperatively. Twenty-eight percent of patients reported better subjective visual quality in the Akreos AO eye and 14%, in the Tecnis Z9000 eye (P<.0001). Accordingly, 33% perceived more visual disturbances in the Tecnis Z9000 eye and 11%, in the Akreos AO eye (P<.0001).
CONCLUSIONS: Maximum reduction of spherical aberration did not maximize subjective visual quality. The higher perceived quality of vision with the Akreos AO IOL could be because of differences in depth of field, IOL material, or IOL design.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17720071     DOI: 10.1016/j.jcrs.2007.05.025

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  13 in total

1.  Visual and optical performance of eyes with different corneal spherical aberration implanted with aspheric intraocular lens.

Authors:  Xian-Hui Gong; Qin-Xiang Zheng; Na Wang; Ding Chen; Juan Zhao; Jin Li; Yun-E Zhao
Journal:  Int J Ophthalmol       Date:  2012-06-18       Impact factor: 1.779

2.  Comparison of contrast sensitivity, depth of field and ocular wavefront aberrations in eyes with an IOL with zero versus positive spherical aberration.

Authors:  Jay S Pepose; Mujtaba A Qazi; Keith H Edwards; Jeff P Sanderson; Edwin J Sarver
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-03-11       Impact factor: 3.117

3.  Higher order aberration comparison between two aspherical intraocular lenses: MC6125AS and Akreos advanced optics.

Authors:  Mohammad Taher Rajabi; Sara Korouji; Mahgol Farjadnia; Mohammad Naderan; Mohammad Bagher Rajabi; Bahram Khosravi; Seyed Mehdi Tabatabaie
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

4.  Clinical outcomes of combined pars plana vitrectomy and trans-scleral 4-point suture fixation of a foldable intraocular lens.

Authors:  Neha Goel
Journal:  Eye (Lond)       Date:  2018-02-05       Impact factor: 3.775

5.  Changes in spherical aberration after various corneal surface ablation techniques.

Authors:  Hyun Seok Ahn; Jae Lim Chung; Eung Kweon Kim; Kyoung Yul Seo; Tae-Im Kim
Journal:  Korean J Ophthalmol       Date:  2013-02-28

6.  A comparative study on visual and optical performance of Akreos AO and Kontur AB IOLs after phacoemulsification cataract surgery.

Authors:  Hamid Gharaee; Masoud Zabihifard; Alireza Eslampour; Samira Hassanzadeh; Masoud Shafiee
Journal:  J Curr Ophthalmol       Date:  2016-03-28

7.  This issue at a glance.

Authors: 
Journal:  J Curr Ophthalmol       Date:  2016-04-12

8.  Visual Outcomes of Two Aspheric PCIOLs: Tecnis Z9000 versus Akreos AO.

Authors:  Ahmad-Reza Baghi; Mohammad-Reza Jafarinasab; Hossein Ziaei; Zahra Rahmani
Journal:  J Ophthalmic Vis Res       Date:  2008-01

9.  Aspheric intraocular lenses implantation for cataract patients with extreme myopia.

Authors:  Yanwen Fang; Yi Lu; Aizhu Miao; Yi Luo
Journal:  ISRN Ophthalmol       Date:  2014-03-19

10.  Effect of Spherical Aberration on the Optical Quality after Implantation of Two Different Aspherical Intraocular Lenses.

Authors:  Michael Lasta; Kata Miháltz; Illés Kovács; Pia Veronika Vécsei-Marlovits
Journal:  J Ophthalmol       Date:  2017-08-16       Impact factor: 1.909

View more