First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: implications for wireless pacing with implantable devices.

Kathy L Lee1, Chu-Pak Lau, Hung-Fat Tse, Debra S Echt, David Heaven, Warren Smith, Margaret Hood.   

Abstract

OBJECTIVES: The purpose of this study was to evaluate the feasibility and safety of a novel technology that uses energy transfer from an ultrasound transmitter to achieve cardiac stimulation without the use of a pacing lead in humans.
BACKGROUND: To overcome the limitations of pacemaker leads, a new technology enabling stimulation without the use of a lead is desirable.
METHODS: A steerable bipolar electrophysiology catheter incorporating a receiver electrode into the tip and circuitry to convert ultrasound energy to electrical energy was inserted transvenously into the heart. An ultrasound transmitting transducer was placed on the chest wall with ultrasound gel. Ultrasound energy was amplitude-adjusted and transmitted at 313 to 385 kHz. The output waveform of the receiver electrode was monitored while the transmitter was moved on the chest wall to target the receiver. The ultrasound transmission amplitude was limited to a mechanical index of 1.9, the maximum allowed for ultrasound imaging systems. Ultrasound-mediated pacing with minimum voltage but consistent capture was obtained for 12 s.
RESULTS: Twenty-four patients (48 +/- 12 years) were tested during or after completion of clinical electrophysiology procedures. A total of 80 pacing sites were tested (mean 3.3 sites/patient): 12 right atrial, 35 right ventricular, and 33 left ventricular (31 endocardial) sites. The transmit-to-receive distance was 11.3 +/- 3.2 cm (range 5.3 to 22.5 cm). Ultrasound-mediated pacing was achieved at all 80 test sites, with consistent capture at 77 sites. The mechanical index during pacing was 0.5 +/- 0.3 (range 0.1 to 1.5). The mean ultrasound-mediated capture threshold was 1.01 +/- 0.64 V. There was no adverse event related to ultrasound pacing. No patient experienced discomfort during pacing.
CONCLUSIONS: The feasibility and safety of pacing usng ultrasound energy has been shown acutely.

Entities:  

Mesh:

Year:  2007        PMID: 17719475     DOI: 10.1016/j.jacc.2007.04.081

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  11 in total

1.  Increasing knowledge and changing views in cardiac resynchronization therapy.

Authors:  Laszlo Buga; John G F Cleland
Journal:  Heart Fail Rev       Date:  2012-11       Impact factor: 4.214

2.  A nonlinear lumped model for ultrasound systems using CMUT arrays.

Authors:  Sarp Satir; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-10       Impact factor: 2.725

3.  Ultrasound-induced heart rate decrease: role of the vagus nerve.

Authors:  Olivia Coiado; Elaine Buiochi; William O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-02       Impact factor: 2.725

Review 4.  [Cardiac resynchronisation therapy : new data and technical developments].

Authors:  C Butter
Journal:  Herz       Date:  2011-10       Impact factor: 1.443

Review 5.  Wireless communication with implanted medical devices using the conductive properties of the body.

Authors:  John E Ferguson; A David Redish
Journal:  Expert Rev Med Devices       Date:  2011-07       Impact factor: 3.166

Review 6.  Past, present, and future of CRT.

Authors:  Angelo Auricchio; François Regoli
Journal:  Heart Fail Rev       Date:  2011-05       Impact factor: 4.214

Review 7.  Pacing device therapy in infants and children: a review.

Authors:  Daiji Takeuchi; Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2012-10-27       Impact factor: 1.731

Review 8.  Leadless Cardiac Pacemakers: Pacing Paradigm Change.

Authors:  Petr Neuzil; Vivek Y Reddy
Journal:  Curr Cardiol Rep       Date:  2015-08       Impact factor: 2.931

Review 9.  State of the art of leadless pacing.

Authors:  Johannes Sperzel; Haran Burri; Daniel Gras; Fleur V Y Tjong; Reinoud E Knops; Gerhard Hindricks; Clemens Steinwender; Pascal Defaye
Journal:  Europace       Date:  2015-05-29       Impact factor: 5.214

Review 10.  Congenital and childhood atrioventricular blocks: pathophysiology and contemporary management.

Authors:  Alban-Elouen Baruteau; Robert H Pass; Jean-Benoit Thambo; Albin Behaghel; Solène Le Pennec; Elodie Perdreau; Nicolas Combes; Leonardo Liberman; Christopher J McLeod
Journal:  Eur J Pediatr       Date:  2016-06-28       Impact factor: 3.183

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.