Literature DB >> 17713761

Application of high-performance liquid chromatography-tandem mass spectrometry with a quadrupole/linear ion trap instrument for the analysis of pesticide residues in olive oil.

M D Hernando1, C Ferrer, M Ulaszewska, J F García-Reyes, A Molina-Díaz, A R Fernández-Alba.   

Abstract

This article describes the development of an enhanced liquid chromatography-mass spectrometry (LC-MS) method for the analysis of pesticides in olive oil. One hundred pesticides belonging to different classes and that are currently used in agriculture have been included in this method. The LC-MS method was developed using a hybrid quadrupole/linear ion trap (QqQ(LIT)) analyzer. Key features of this technique are the rapid scan acquisition times, high specificity and high sensitivity it enables when the multiple reaction monitoring (MRM) mode or the linear ion-trap operational mode is employed. The application of 5 ms dwell times using a linearly accelerating (LINAC) high-pressure collision cell enabled the analysis of a high number of pesticides, with enough data points acquired for optimal peak definition in MRM operation mode and for satisfactory quantitative determinations to be made. The method quantifies over a linear dynamic range of LOQs (0.03-10 microg kg(-1)) up to 500 microg kg(-1). Matrix effects were evaluated by comparing the slopes of matrix-matched and solvent-based calibration curves. Weak suppression or enhancement of signals was observed (<15% for most-80-of the pesticides). A study to assess the identification criteria based on the MRM ratio was carried out by comparing the variations observed in standard vs matrix (in terms of coefficient of variation, CV%) and within the linear range of concentrations studied. The CV was lower than 15% when the response observed in solvent was compared to that in olive oil. The limit of detection was < or =10 microg kg(-1) for five of the selected pesticides, < or =5 microg kg(-1) for 14, and < or =1 microg kg(-1) for 81 pesticides. For pesticides where additional structural information was necessary for confirmatory purposes-in particular at low concentrations, since the second transition could not be detected-survey scans for enhanced product ion (EPI) and MS3 were developed.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17713761     DOI: 10.1007/s00216-007-1464-z

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  6 in total

1.  Bioconcentration, metabolism and excretion of triclocarban in larval Qurt medaka (Oryzias latipes).

Authors:  Nils Helge Schebb; Ida Flores; Tomofumi Kurobe; Bastian Franze; Anupama Ranganathan; Bruce D Hammock; Swee J Teh
Journal:  Aquat Toxicol       Date:  2011-08-04       Impact factor: 4.964

2.  Investigation of human exposure to triclocarban after showering and preliminary evaluation of its biological effects.

Authors:  Nils Helge Schebb; Bora Inceoglu; Ki Chang Ahn; Christophe Morisseau; Shirley J Gee; Bruce D Hammock
Journal:  Environ Sci Technol       Date:  2011-03-07       Impact factor: 9.028

3.  Immunochemical screening of pesticides (simazine and cypermethrin) in orange oil.

Authors:  Mikaela Nichkova; Xun Fu; Zheng Yang; Ping Zhong; James R Sanborn; Dan Chang; Shirley J Gee; Bruce D Hammock
Journal:  J Agric Food Chem       Date:  2009-07-08       Impact factor: 5.279

4.  Structural characterization of monoterpene indole alkaloids in ethanolic extracts of Rauwolfia species by liquid chromatography with quadrupole time-of-flight mass spectrometry.

Authors:  Sunil Kumar; Awantika Singh; Vikas Bajpai; Mukesh Srivastava; Bhim Pratap Singh; Brijesh Kumar
Journal:  J Pharm Anal       Date:  2016-05-07

5.  Comparison of Different d-SPE Sorbent Performances Based on Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) Methodology for Multiresidue Pesticide Analyses in Rapeseeds.

Authors:  Saida Belarbi; Martin Vivier; Wafa Zaghouani; Aude De Sloovere; Valerie Agasse; Pascal Cardinael
Journal:  Molecules       Date:  2021-11-06       Impact factor: 4.411

6.  Comparison of the Multiple Reaction Monitoring and Enhanced Product Ion Scan Modes for Confirmation of Stilbenes in Bovine Urine Samples Using LC-MS/MS QTRAP® System.

Authors:  Iwona Matraszek-Zuchowska; Barbara Wozniak; Andrzej Posyniak
Journal:  Chromatographia       Date:  2016-07-05       Impact factor: 2.044

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.