Literature DB >> 17710474

Early results of endovascular treatment of the thoracic aorta using the Valiant endograft.

Matt Thompson1, Stella Ivaz, Nicholas Cheshire, Rosella Fattori, Herve Rousseau, Robin Heijmen, Jean-Paul Beregi, Frederic Thony, Gillian Horne, Robert Morgan, Ian Loftus.   

Abstract

Endovascular repair of the thoracic aorta has been adopted as the first-line therapy for much pathology. Initial results from the early-generation endografts have highlighted the potential of this technique. Newer-generation endografts have now been introduced into clinical practice and careful assessment of their performance should be mandatory. This study describes the initial experience with the Valiant endograft and makes comparisons with similar series documenting previous-generation endografts. Data were retrospectively collected on 180 patients treated with the Valiant endograft at seven European centers between March 2005 and October 2006. The patient cohort consisted of 66 patients with thoracic aneurysms, 22 with thoracoabdominal aneurysms, 19 with an acute aortic syndrome, 52 with aneurysmal degeneration of a chronic dissection, and 21 patients with traumatic aortic transection. The overall 30-day mortality for the series was 7.2%, with a stroke rate of 3.8% and a paraplegia rate of 3.3%. Subgroup analysis demonstrated that mortality differed significantly between different indications; thoracic aneurysms (6.1%), thoracoabdominal aneurysms (27.3%), acute aortic syndrome (10.5%), chronic dissections (1.9%), and acute transections (0%). Adjunctive surgical procedures were required in 63 patients, and 51% of patients had grafts deployed proximal to the left subclavian artery. Comparison with a series of earlier-generation grafts demonstrated a significant increase in complexity of procedure as assessed by graft implantation site, number of grafts and patient comorbidity. The data demonstrate acceptable results for a new-generation endograft in series of patients with diverse thoracic aortic pathology. Comparison of clinical outcomes between different endografts poses considerable challenges due to differing case complexity.

Entities:  

Mesh:

Year:  2007        PMID: 17710474     DOI: 10.1007/s00270-007-9147-x

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  6 in total

1.  Intervention on thoracic and thoracoabdominal aortic aneurysms: can the UK offer a service?

Authors:  Mark L Field; Debbie Harrington; Mohamad Bashir; Manoj Kuduvalli; Aung Oo
Journal:  J R Soc Med       Date:  2012-11       Impact factor: 5.344

2.  Thoracic endovascular repair of chronic type B aortic dissection: a systematic review.

Authors:  Michael L Williams; Madeleine de Boer; Bridget Hwang; Bruce Wilson; John Brookes; Nicholas McNamara; David H Tian; Timothy Shiraev; Ourania Preventza
Journal:  Ann Cardiothorac Surg       Date:  2022-01

3.  Clinical Outcomes of Left Subclavian Artery Coverage on Morbidity and Mortality During Thoracic Endovascular Aortic Repair for Distal Arch Aneurysms.

Authors:  Takeshi Baba; Takao Ohki; Yuji Kanaoka; Koji Maeda
Journal:  World J Surg       Date:  2015-11       Impact factor: 3.352

4.  Management strategies for thoracic stent-graft repair of distal aortic arch lesions: is intentional subclavian artery occlusion a safe procedure?

Authors:  Fabrizio Fanelli; Michael D Dake; Filippo Maria Salvatori; Armando Pucci; Giuseppe Mazzesi; Pierleone Lucatelli; Plinio Rossi; Roberto Passariello
Journal:  Eur Radiol       Date:  2009-05-09       Impact factor: 5.315

5.  Conservative management versus endovascular or open surgery in the spectrum of type B aortic dissection.

Authors:  Xun Yuan; Andreas Mitsis; Mohammed Ghonem; Ilias Iakovakis; Christoph A Nienaber
Journal:  J Vis Surg       Date:  2018-03-23

Review 6.  Revascularisation of the left subclavian artery for thoracic endovascular aortic repair.

Authors:  Shahin Hajibandeh; Shahab Hajibandeh; Stavros A Antoniou; Francesco Torella; George A Antoniou
Journal:  Cochrane Database Syst Rev       Date:  2016-04-27
  6 in total