Novel Materials for Low-Contrast Phantoms for Computed Tomography.

Keana D Allert1, Sravanthi Vangala, Frank A Dibianca.   

Abstract

Acceptance testing and quality control of computed tomography (CT) scanners are of great importance. While most procedures and phantoms for testing other parameters are widely accepted, there is still discussion and uncertainty about low-contrast (LC) performance tests that measure the capability of a CT scanner to discriminate low-contrast objects. This work investigated the development of LC phantoms with available, low-cost polystyrene resin materials and some selected additives. We designed and tested phantoms with several different contrast steps by generating contrast in two different ways, one based on 'physical density difference' and the other on 'atomic number difference'. Physical density difference was achieved by adding a small amount of glycerin to the polystyrene resin, both having similar low atomic-number elements but differing in the density of their atoms. Atomic number difference was achieved by adding a small amount of iodobenzene to the resin, both having approximately the same physical density (less than 1% variation in density) but different atomic (i.e., elemental) composition. Prototypes were evaluated using a Philips Tomoscan LX system and varying beam properties. The behavior and validity of the results are discussed.

Entities:  

Year:  2007        PMID: 17710119      PMCID: PMC1945223     

Source DB:  PubMed          Journal:  J Xray Sci Technol        ISSN: 0895-3996            Impact factor:   1.535


  6 in total

1.  A variable resolution x-ray detector for computed tomography: I. Theoretical basis and experimental verification.

Authors:  F A DiBianca; V Gupta; H D Zeman
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

2.  A variable resolution x-ray detector for computed tomography: II. Imaging theory and performance.

Authors:  F A DiBianca; P Zou; L M Jordan; J S Laughter; H D Zeman; J Sebes
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

Review 3.  Toward consensus on quantitative assessment of medical imaging systems.

Authors:  C E Metz; R F Wagner; K Doi; D G Brown; R M Nishikawa; K J Myers
Journal:  Med Phys       Date:  1995-07       Impact factor: 4.071

4.  Factors related to low contrast resolution in CT scanners.

Authors:  D J Goodenough; K E Weaver
Journal:  Comput Radiol       Date:  1984 Sep-Oct

5.  The use of contrast -- detail -- dose evaluation of image quality in a computed tomographic scanner.

Authors:  G Cohen; F A DiBianca
Journal:  J Comput Assist Tomogr       Date:  1979-04       Impact factor: 1.826

6.  CT scanning: patterns of use and dose.

Authors:  F A Mettler; P W Wiest; J A Locken; C A Kelsey
Journal:  J Radiol Prot       Date:  2000-12       Impact factor: 1.394

  6 in total
  2 in total

Review 1.  Physical imaging phantoms for simulation of tumor heterogeneity in PET, CT, and MRI: An overview of existing designs.

Authors:  Alejandra Valladares; Thomas Beyer; Ivo Rausch
Journal:  Med Phys       Date:  2020-02-12       Impact factor: 4.071

2.  Automated development of the contrast-detail curve based on statistical low-contrast detectability in CT images.

Authors:  Choirul Anam; Ariij Naufal; Toshioh Fujibuchi; Kosuke Matsubara; Geoff Dougherty
Journal:  J Appl Clin Med Phys       Date:  2022-07-09       Impact factor: 2.243

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.