Literature DB >> 17709837

Intraindividual comparison of high-spatial-resolution abdominal MR angiography at 1.5 T and 3.0 T: initial experience.

Henrik J Michaely1, Harald Kramer, Olaf Dietrich, Kambiz Nael, Klaus-Peter Lodemann, Maximilian F Reiser, Stefan O Schoenberg.   

Abstract

PURPOSE: To prospectively compare three-dimensional (3D) contrast material-enhanced abdominal magnetic resonance (MR) angiography at 1.5 and 3.0 T intraindividually in healthy volunteers.
MATERIALS AND METHODS: After institutional review board approval and informed consent were obtained, 15 healthy male volunteers (age range, 24-41 years) underwent one abdominal 3D contrast-enhanced MR angiographic examination each at 1.5 and 3.0 T in random order. Fast 3D gradient-echo sequence with parallel imaging acceleration factor of three was used for MR angiography; acquired spatial resolutions were 1x0.8x1 mm3 (imaging time, 19 seconds) at 1.5 T and 0.9x0.8x0.9 mm3 (imaging time, 18 seconds) at 3.0 T. With the latter, volume of the 3D slab was 8% larger. At 1.5 T, 20-mL bolus of gadobenate dimeglumine was delivered at 2 mL/sec; at 3.0 T, 15-mL bolus was delivered at 2.5 mL/sec. Two blinded radiologists rated image quality of aorta and proximal renal arteries in consensus with five-point scale (4=very good, 0=nondiagnostic) according to sequence and in direct intraindividual comparison. Visibility of proximal and segmental renal arteries was rated with three-point scale (3=completely visible, 1=nonvisible). Signal-to-noise ratio (SNR) was determined with phantoms. For statistical analysis of the SNRs, t tests were used.
RESULTS: All MR angiographic measurements were diagnostic. Median score for image quality at both field strengths was 4. Depiction of proximal renal arteries was rated 3 at both field strengths. The visibility of the distal renal arteries was better at 3.0 T (median score, 3) than at 1.5 T (median score, 2). With direct comparison, 3.0-T MR angiography was better in 14 of 15 cases; no field strength was preferred in the other case. Mean SNR was significantly (P<.001) higher at 3.0 T (17.8+/-0.09 [standard deviation]) than at 1.5 T (11.9+/-0.10).
CONCLUSION: MR angiography at 3.0 T provided better vessel visibility and SNR than did that at 1.5 T, although voxel size and imaging time were reduced. Copyright (c) RSNA, 2007.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17709837     DOI: 10.1148/radiol.2443061647

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  15 in total

1.  Renal arteries: isotropic, high-spatial-resolution, unenhanced MR angiography with three-dimensional radial phase contrast.

Authors:  Christopher J François; Darren P Lum; Kevin M Johnson; Benjamin R Landgraf; Thorsten A Bley; Scott B Reeder; Mark L Schiebler; Thomas M Grist; Oliver Wieben
Journal:  Radiology       Date:  2010-10-27       Impact factor: 11.105

2.  Optimized high-resolution contrast-enhanced hepatobiliary imaging at 3 tesla: a cross-over comparison of gadobenate dimeglumine and gadoxetic acid.

Authors:  Alex Frydrychowicz; Scott K Nagle; Sharon L D'Souza; Karl K Vigen; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2011-07-12       Impact factor: 4.813

3.  Improved quality and diagnostic confidence achieved by use of dose-reduced gadolinium blood-pool agents for time-resolved intracranial MR angiography.

Authors:  S Dehkharghani; J Kang; A M Saindane
Journal:  AJNR Am J Neuroradiol       Date:  2013-08-22       Impact factor: 3.825

4.  CAIPIRINHA-VIBE and GRAPPA-VIBE for liver MRI at 1.5 T: a comparative in vivo patient study.

Authors:  Ajaykumar C Morani; Rafael A Vicens; Wei Wei; Shiva Gupta; Raghu Vikram; Aparna Balachandran; Brandy J Reed; Jingfei Ma; Aliya Qayyum; Janio Szklaruk
Journal:  J Comput Assist Tomogr       Date:  2015 Mar-Apr       Impact factor: 1.826

5.  First-pass contrast-enhanced renal MRA at 7 Tesla: initial results.

Authors:  L Umutlu; S Maderwald; S Kinner; O Kraff; A K Bitz; S Orzada; S Johst; K Wrede; M Forsting; M E Ladd; T C Lauenstein; H H Quick
Journal:  Eur Radiol       Date:  2012-10-14       Impact factor: 5.315

6.  Assessment of the kidneys: magnetic resonance angiography, perfusion and diffusion.

Authors:  Ulrike I Attenberger; John N Morelli; Stefan O Schoenberg; Henrik J Michaely
Journal:  J Cardiovasc Magn Reson       Date:  2011-11-15       Impact factor: 5.364

7.  Comparison of 1.5 and 3.0 T for contrast-enhanced pulmonary magnetic resonance angiography.

Authors:  Frank Joseph Londy; Suzan Lowe; Paul D Stein; John G Weg; Robert L Eisner; Kenneth V Leeper; Pamela K Woodard; H Dirk Sostman; Kathleen A Jablonski; Sarah E Fowler; Charles A Hales; Russell D Hull; Alexander Gottschalk; David P Naidich; Thomas L Chenevert
Journal:  Clin Appl Thromb Hemost       Date:  2011-10-12       Impact factor: 2.389

Review 8.  [Vascular and parenchymal diseases of the kidney].

Authors:  H J Michaely; M Reichert; S Weckbach; S O Schoenberg
Journal:  Radiologe       Date:  2008-02       Impact factor: 0.635

9.  Boosting magnetic resonance imaging signal-to-noise ratio using magnetic metamaterials.

Authors:  Guangwu Duan; Xiaoguang Zhao; Stephan William Anderson; Xin Zhang
Journal:  Commun Phys       Date:  2019-03-26

10.  64-Slice CT angiography of the abdominal aorta and abdominal arteries: comparison of the diagnostic efficacy of iobitridol 350 mgI/ml versus iomeprol 400 mgI/ml in a prospective, randomised, double-blind multi-centre trial.

Authors:  Christian Loewe; Christoph R Becker; Riccardo Berletti; Carlo Alberto Cametti; Jerome Caudron; Walter Coudyzer; Johan De Mey; Massimo Favat; Jean-François Heautot; Sam Heye; Markus Hittinger; Antoine Larralde; Jean-Pierre Lestrat; Roberto Marangoni; Koenraad Nieboer; Peter Reimer; Martin Schwarz; Melanie Schernthaner; Johannes Lammer
Journal:  Eur Radiol       Date:  2009-09-30       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.