A comparison between 2-Step IMRT and conventional IMRT planning.

Klaus Bratengeier1, Matthias Guckenberger, Jürgen Meyer, Gerd Müller, Leo Pfreundner, Franz Schwab, Michael Flentje.   

Abstract

BACKGROUND AND
PURPOSE: 2-Step intensity modulated radiation therapy (2-Step IMRT) is an IMRT segmentation procedure based on analytical approximations [Bratengeier K. 2-Step IMAT and 2-Step IMRT: a geometrical approach. Med Phys 2005;32:777-785; Bratengeier K. 2-Step IMAT and 2-Step IMRT in three dimensions. Med Phys 2005;32:3849-3861]. The aim was to benchmark it with other IMRT algorithms and to establish it as planning tool for fast IMRT application with a reduced number of segments.
MATERIALS AND METHODS: 2-Step IMRT plans were compared with IMRT-solutions obtained with methods from a commercial planning system (Pinnacletrade mark TPS). The four clinical cases chosen were: paraspinal tumour, carcinoma of the prostate, head and neck carcinoma and breast carcinoma. In addition the "Quasimodo" phantom study was used to compare the quality of the 2-Step IMRT method with respect to other planning procedures in the ESTRO study.
RESULTS: The number of segments (and - to a minor degree - the monitor units per dose) of the majority of 2-Step IMRT plans was lower than for the commercial algorithms. The quality of the 2-Step IMRT-plan was comparable. In the Quasimodo comparison 2-Step IMRT plans with nine beams would place in the mid-range of all participants, whereas the 15-beam arrangements could compete with the best results.
CONCLUSIONS: 2-Step IMRT is a valuable IMRT segmentation method, especially if the number of segments is to be limited (e.g. for reasons of precision, speed and leakage radiation).

Entities:  

Mesh:

Year:  2007        PMID: 17707937     DOI: 10.1016/j.radonc.2007.06.018

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  7 in total

1.  Quality Control of Portal Imaging with PTW EPID QC PHANTOM.

Authors:  Csilla Pesznyák; Gábor Fekete; Arpád Mózes; Balázs Kiss; Réka Király; István Polgár; Pál Zaránd; Arpád Mayer
Journal:  Strahlenther Onkol       Date:  2009-02-18       Impact factor: 3.621

2.  Pre-segmented 2-Step IMRT with subsequent direct machine parameter optimisation - a planning study.

Authors:  Klaus Bratengeier; Jürgen Meyer; Michael Flentje
Journal:  Radiat Oncol       Date:  2008-11-06       Impact factor: 3.481

3.  Dosimetric comparison using different multileaf collimeters in intensity-modulated radiotherapy for upper thoracic esophageal cancer.

Authors:  Youling Gong; Shichao Wang; Lin Zhou; Yongmei Liu; Yong Xu; You Lu; Sen Bai; Yuchuan Fu; Qingfeng Xu; Qingfeng Jiang
Journal:  Radiat Oncol       Date:  2010-07-15       Impact factor: 3.481

4.  Two-step intensity modulated arc therapy (2-step IMAT) with segment weight and width optimization.

Authors:  Jidi Sun; Theam Yong Chew; Juergen Meyer
Journal:  Radiat Oncol       Date:  2011-06-02       Impact factor: 3.481

5.  Fast IMRT by increasing the beam number and reducing the number of segments.

Authors:  Klaus Bratengeier; Mark B Gainey; Michael Flentje
Journal:  Radiat Oncol       Date:  2011-12-09       Impact factor: 3.481

6.  Towards automated on-line adaptation of 2-Step IMRT plans: QUASIMODO phantom and prostate cancer cases.

Authors:  Kostyantyn Holubyev; Klaus Bratengeier; Mark Gainey; Bülent Polat; Michael Flentje
Journal:  Radiat Oncol       Date:  2013-11-08       Impact factor: 3.481

7.  A fast radiotherapy paradigm for anal cancer with volumetric modulated arc therapy (VMAT).

Authors:  Florian Stieler; Dirk Wolff; Frank Lohr; Volker Steil; Yasser Abo-Madyan; Friedlieb Lorenz; Frederik Wenz; Sabine Mai
Journal:  Radiat Oncol       Date:  2009-10-25       Impact factor: 3.481

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.