Literature DB >> 17703658

In vivo ultrasound biomicroscopy of skin: spectral system characteristics and inverse filtering optimization.

Michael Vogt1, Helmut Ermert.   

Abstract

High-frequency ultrasound (HFUS) in the 20 MHz to 100 MHz range has to meet the opposite requirements of good spatial resolution and of high penetration depth for in vivo ultrasound biomicroscopy (UBM) of skin. The attenuation of water, which serves as sound propagation medium between utilized single element transducers and the skin, becomes very eminent with increasing frequency. Furthermore, the spectra of acquired radio frequency (rf) echo signals change over depth because of the diffracted sound field characteristics. The reduction of the system's center frequency and bandwidth causes a significant loss of spatial resolution over depth. In this paper, the spectral characteristics of HFUS imaging systems and the potential of inverse echo signal filtering for the optimization of pulse-echo measurements is analyzed and validated. A Gaussian model of the system's transfer function, which takes into account the frequency-dependent attenuation of the water path, was developed. Predictions of system performance are derived from this model and compared with measurement results. The design of a HFUS skin imaging system with a 100 MHz range transducer and a broadband driving electronics is discussed. A time-variant filter for inverse rf echo signal filtering was designed to compensate the system's depth-dependent imaging properties. Results of in vivo measurements are shown and discussed.

Entities:  

Mesh:

Year:  2007        PMID: 17703658     DOI: 10.1109/tuffc.2007.425

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  11 in total

1.  40-MHz ultrasound imaging with chirps and annular arrays.

Authors:  Jonathan Mamou; Orlando Aristizábal; Ronald H Silverman; Jeffrey A Ketterling
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2008

2.  Comparison of articular cartilage images assessed by high-frequency ultrasound microscope and scanning acoustic microscope.

Authors:  Yoshihiro Hagiwara; Yoshifumi Saijo; Akira Ando; Yoshito Onoda; Hideaki Suda; Eiichi Chimoto; Kouki Hatori; Eiji Itoi
Journal:  Int Orthop       Date:  2011-05-13       Impact factor: 3.075

3.  An Efficient Melanoma Diagnosis Approach Using Integrated HMF Multi-Atlas Map Based Segmentation.

Authors:  D Roja Ramani; S Siva Ranjani
Journal:  J Med Syst       Date:  2019-06-12       Impact factor: 4.460

4.  Three-dimensional high-frequency backscatter and envelope quantification of cancerous human lymph nodes.

Authors:  Jonathan Mamou; Alain Coron; Michael L Oelze; Emi Saegusa-Beecroft; Masaki Hata; Paul Lee; Junji Machi; Eugene Yanagihara; Pascal Laugier; Ernest J Feleppa
Journal:  Ultrasound Med Biol       Date:  2011-03       Impact factor: 2.998

5.  Three-dimensional high-frequency characterization of cancerous lymph nodes.

Authors:  Jonathan Mamou; Alain Coron; Masaki Hata; Junji Machi; Eugene Yanagihara; Pascal Laugier; Ernest J Feleppa
Journal:  Ultrasound Med Biol       Date:  2010-02-04       Impact factor: 2.998

6.  Melanoma Is Skin Deep: A 3D Reconstruction Technique for Computerized Dermoscopic Skin Lesion Classification.

Authors:  T Y Satheesha; D Satyanarayana; M N Giri Prasad; Kashyap D Dhruve
Journal:  IEEE J Transl Eng Health Med       Date:  2017-01-16       Impact factor: 3.316

7.  A flexible annular-array imaging platform for micro-ultrasound.

Authors:  Weibao Qiu; Yanyan Yu; Hamid Reza Chabok; Cheng Liu; Fu Keung Tsang; Qifa Zhou; K Kirk Shung; Hairong Zheng; Lei Sun
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-01       Impact factor: 2.725

8.  High-frequency chirp ultrasound imaging with an annular array for ophthalmologic and small-animal imaging.

Authors:  Jonathan Mamou; Orlando Aristizábal; Ronald H Silverman; Jeffrey A Ketterling; Daniel H Turnbull
Journal:  Ultrasound Med Biol       Date:  2009-04-25       Impact factor: 2.998

9.  A post-beamforming 2-D pseudoinverse filter for coarsely sampled ultrasound arrays.

Authors:  Yayun Wan; Emad S Ebbini
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-09       Impact factor: 2.725

10.  Ultrasound Surface Wave Elastography for Assessing Scleroderma.

Authors:  Xiaoming Zhang; Boran Zhou; Thomas Osborn
Journal:  Ultrasound Med Biol       Date:  2020-02-25       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.