Literature DB >> 17703339

Predicting breast attenuation in patients undergoing myocardial perfusion scintigraphy: a digital x-ray study.

Zekeriya Nurkalem1, Sinan Sahin, Nevzat Uslu, Ayse Emre, Ahmet Taha Alper, Sevket Gorgulu, Fehmi Yardi, Mehmet Eren.   

Abstract

Attenuation artifacts are the most common sources of error in myocardial single-photon emission computed tomography (SPECT) imaging. Breast artifacts are the most frequent causes of false positive planar images in female subjects. The purpose of this study was to predict breast adverse attenuation by measuring breast tissue thickness with digital x-ray. Sixty-five consecutive female patients with angina pectoris, who were referred to myocardial perfusion scintigraphy were enrolled in this study. Eighteen patients with normal perfusion imaging and normal coronary angiography composed the first group, whereas the second group consisted of 28 patients with a positive exercise electrocardiogram with anterior ischemia on myocardial perfusion imaging and greater than 50% left anterior descending artery stenosis on angiography. Nineteen patients in the third group had normal exercise electrocardiograms and normal coronary angiographies, but anterior ischemia on perfusion imaging. Digital x-ray records were obtained for measuring breast tissue thickness and Hounsfield density. The rate of breast adverse attenuation was 40% (19/47) in patients with anterior ischemia. The sensitivity and specificity of the prediction of breast adverse attenuation (lateral density less than 550 Hounsfield) were 79% and 11%, respectively. When breast attenuation for a breast thickness greater than 6 cm measured in the left anterior oblique view was predicted, the sensitivity and specificity were 79% and 93%, respectively. In conclusion, breast thickness greater than 6 cm measured from the left anterior oblique view with digital x-ray can predict breast adverse attenuation in female patients, and thereby may decrease the number of unnecessary invasive diagnostic procedures to be performed.

Entities:  

Mesh:

Year:  2007        PMID: 17703339      PMCID: PMC3043850          DOI: 10.1007/s10278-007-9048-1

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  15 in total

1.  Comparison of the cost-effectiveness of stress myocardial SPECT and stress echocardiography in suspected coronary artery disease considering the prognostic value of false-negative results.

Authors:  Dong Soo Lee; Myoung Jin Jang; Gi Jeong Cheon; June-Key Chung; Myung Chul Lee
Journal:  J Nucl Cardiol       Date:  2002 Sep-Oct       Impact factor: 5.952

2.  Appearance of breast attenuation artifacts with thallium myocardial SPECT imaging.

Authors:  P R Garver; R D Wasnich; A M Shibuya; F Yeh
Journal:  Clin Nucl Med       Date:  1985-10       Impact factor: 7.794

3.  Effect of patient obesity on the accuracy of thallium-201 myocardial perfusion imaging.

Authors:  C L Hansen; S Woodhouse; M Kramer
Journal:  Am J Cardiol       Date:  2000-03-15       Impact factor: 2.778

4.  High-resolution computed tomography for the comparative study of fossil and extant bone.

Authors:  J R Tate; C E Cann
Journal:  Am J Phys Anthropol       Date:  1982-05       Impact factor: 2.868

5.  Acute ischemic dysfunction alters coronary flow reserve in remote nonischemic regions: potential mechanical etiology identified in an acute canine model.

Authors:  E Daher; D P Dione; E N Heller; J Holahan; P DeMan; M Shen; J Hu; A J Sinusas
Journal:  J Nucl Cardiol       Date:  2000 Mar-Apr       Impact factor: 5.952

6.  Initial experience with X-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system.

Authors:  Daisuke Utsunomiya; Seiji Tomiguchi; Shinya Shiraishi; Koichiro Yamada; Tsuyoshi Honda; Koichi Kawanaka; Akihiro Kojima; Kazuo Awai; Yasuyuki Yamashita
Journal:  Ann Nucl Med       Date:  2005-09       Impact factor: 2.668

7.  Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound.

Authors:  A F Kopp; S Schroeder; A Baumbach; A Kuettner; C Georg; B Ohnesorge; M Heuschmid; R Kuzo; C D Claussen
Journal:  Eur Radiol       Date:  2001       Impact factor: 5.315

Review 8.  Myocardial perfusion imaging with technetium-99m sestamibi SPECT in the evaluation of coronary artery disease.

Authors:  J Maddahi; H Kiat; K F Van Train; F Prigent; J Friedman; E V Garcia; N Alazraki; E G DePuey; K Nichols; D S Berman
Journal:  Am J Cardiol       Date:  1990-10-16       Impact factor: 2.778

Review 9.  Quantitative and qualitative coronary angiographic analysis: review of methods, utility, and limitations.

Authors:  J B Hermiller; J T Cusma; L A Spero; D F Fortin; M B Harding; T M Bashore
Journal:  Cathet Cardiovasc Diagn       Date:  1992-02

10.  High reproducibility of myocardial perfusion defects in patients undergoing serial exercise thallium-201 tomography.

Authors:  J J Mahmarian; L A Moyé; M S Verani; M F Bloom; C M Pratt
Journal:  Am J Cardiol       Date:  1995-06-01       Impact factor: 2.778

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.