Literature DB >> 17702599

Analysis of PBDEs in soil, dust, spiked lake water, and human serum samples by hollow fiber-liquid phase microextraction combined with GC-ICP-MS.

Qin Xiao1, Bin Hu, Jiankun Duan, Man He, Wanqing Zu.   

Abstract

A novel method for the analysis of four polybrominated diphenyl ethers (PBDEs) in environmental and human serum samples based on hollow fiber-liquid phase microextraction (HF-LPME) followed by gas chromatography-inductively coupled plasma mass spectrometric (GC-ICP-MS) detection has been developed. The organic solvent in the porous hollow fiber was first dipped into the sample for extraction at a given time, and the retracted organic phase was introduced into the GC-ICP-MS for analysis. The addition of methanol has a strong effect on the HF-LPME extraction efficiency. Other significant parameters affecting the extraction efficiency of HF-LPME were also studied. HF-LPME was effective to isolate the analytes from the complex matrix. Under the optimized conditions, the detection limits of the proposed method varied from 15.2 to 40.5 ng/L. In general, the relative standard deviations (RSDs) were less than 10%. Good linearity was obtained with the correlation coefficients all better than 0.999. The proposed method is simple, quick, few microliters of organic solvent required, and is especially suitable for the analysis of the real sample with small amount available. The overall process of HF-LPME with GC-ICP-MS was applied successfully for the determination of polybrominated diphenyl ethers (PBDEs) in environmental and spiked human serum samples, and the results were satisfactory.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17702599     DOI: 10.1016/j.jasms.2007.07.006

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  23 in total

1.  Simultaneous monitoring of volatile selenium and sulfur species from se accumulating plants (wild type and genetically modified) by GC/MS and GC/ICPMS using solid-phase microextraction for sample introduction.

Authors:  Juris Meija; Maria Montes-Bayón; Danika L Le Duc; Norman Terry; Joseph A Caruso
Journal:  Anal Chem       Date:  2002-11-15       Impact factor: 6.986

2.  Liquid-phase microextraction combined with hollow fiber as a sample preparation technique prior to gas chromatography/mass spectrometry.

Authors:  Limian Zhao; Hian Kee Lee
Journal:  Anal Chem       Date:  2002-06-01       Impact factor: 6.986

3.  Rapid identification of RoHS-relevant flame retardants from polymer housings by ultrasonic extraction and RP-HPLC/UV.

Authors:  Manfred Pöhlein; Ana Segura Llopis; Marion Wolf; Rudi van Eldik
Journal:  J Chromatogr A       Date:  2005-02-25       Impact factor: 4.759

4.  Determination of polybrominated diphenyl ethers at trace levels in environmental waters using hollow-fiber microporous membrane liquid-liquid extraction and gas chromatography-mass spectrometry.

Authors:  Núria Fontanals; Thaer Barri; Staffan Bergström; Jan-Ake Jönsson
Journal:  J Chromatogr A       Date:  2006-09-11       Impact factor: 4.759

5.  Alteration of steroid hormone balance in juvenile turbot (Psetta maxima) exposed to nonylphenol, bisphenol A, tetrabromodiphenyl ether 47, diallylphthalate, oil, and oil spiked with alkylphenols.

Authors:  Pierre Labadie; Hélène Budzinski
Journal:  Arch Environ Contam Toxicol       Date:  2006-01-24       Impact factor: 2.804

6.  Simultaneous derivatization and extraction of primary amines in river water with dynamic hollow fiber liquid-phase microextraction followed by gas chromatography-mass spectrometric detection.

Authors:  Kan-Jung Chia; Shang-Da Huang
Journal:  J Chromatogr A       Date:  2005-12-15       Impact factor: 4.759

7.  Optimized method for the determination of 25 polychlorinated biphenyls in water samples using stir bar sorptive extraction followed by thermodesorption-gas chromatography/mass spectrometry.

Authors:  P Popp; P Keil; L Montero; M Rückert
Journal:  J Chromatogr A       Date:  2005-04-15       Impact factor: 4.759

8.  Liquid-liquid-liquid microextraction for sample preparation of biological fluids prior to capillary electrophoresis.

Authors:  S Pedersen-Bjergaard; K E Rasmussen
Journal:  Anal Chem       Date:  1999-07-15       Impact factor: 6.986

9.  Headspace solid-phase microextraction gas chromatography tandem mass spectrometry for the determination of brominated flame retardants in environmental solid samples.

Authors:  Carmen Salgado-Petinal; Maria Garcia-Chao; Maria Llompart; Carmen Garcia-Jares; Rafael Cela
Journal:  Anal Bioanal Chem       Date:  2006-05-03       Impact factor: 4.142

10.  Hollow fiber-protected liquid-phase microextraction of triazine herbicides.

Authors:  Gang Shen; Hian Kee Lee
Journal:  Anal Chem       Date:  2002-02-01       Impact factor: 6.986

View more
  1 in total

Review 1.  Polybrominated diphenyl ethers in the environmental systems: a review.

Authors:  Chinemerem Ruth Ohoro; Abiodun Olagoke Adeniji; Anthony Ifeanyi Okoh; Omobola Oluranti Okoh
Journal:  J Environ Health Sci Eng       Date:  2021-04-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.