Literature DB >> 16715283

Headspace solid-phase microextraction gas chromatography tandem mass spectrometry for the determination of brominated flame retardants in environmental solid samples.

Carmen Salgado-Petinal1, Maria Garcia-Chao, Maria Llompart, Carmen Garcia-Jares, Rafael Cela.   

Abstract

A headspace solid-phase microextraction gas chromatography coupled with tandem mass spectrometry (HSSPME-GC-MS-MS) methodology for determination of brominated flame retardants in sediment and soil samples is presented. To the best of our knowledge, this is the first time that SPME has been applied to analyze polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) in environmental solid samples. Analyses were performed using 0.5-g solid samples moisturized with 2 mL water, employing a polydimethylsiloxane (PDMS) fiber coating, exposed to the headspace at 100 degrees C for 60 min. Several types of environmental solid samples were included in this study and the extraction efficiency was related to the organic matter content of the sample. Calibration was performed using real samples, and the method showed good linearity over a wide concentration range, precision, and afforded quantitative recoveries. The obtained detection limits were in the sub-ng g(-1) for all the target analytes in both samples. The proposed procedure was applied to several marine and river sediments and soils, some of which were found to contain PBDEs at concentrations in the ng g(-1) level; BDE-47, BDE-100, and BDE-99 were the major congeners detected. The proposed method constitutes a rapid and low-cost alternative for the analysis of the target brominated flame retardants in environmental solid samples, since the clean-up steps, fractionation, and preconcentration of extracts inherent to the classical multi-step solvent extraction procedures are avoided.

Entities:  

Year:  2006        PMID: 16715283     DOI: 10.1007/s00216-006-0440-3

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  2 in total

1.  Analysis of PBDEs in soil, dust, spiked lake water, and human serum samples by hollow fiber-liquid phase microextraction combined with GC-ICP-MS.

Authors:  Qin Xiao; Bin Hu; Jiankun Duan; Man He; Wanqing Zu
Journal:  J Am Soc Mass Spectrom       Date:  2007-07-17       Impact factor: 3.109

2.  Protocol for solid-phase microextraction method development.

Authors:  Sanja Risticevic; Heather Lord; Tadeusz Górecki; Catherine L Arthur; Janusz Pawliszyn
Journal:  Nat Protoc       Date:  2010-01-07       Impact factor: 13.491

  2 in total