Literature DB >> 17693335

Reliability and normative database of the Zebris cervical range-of-motion system in healthy controls with preliminary validation in a group of patients with neck pain.

Barbara Cagnie1, Ann Cools, Veerle De Loose, Dirk Cambier, Lieven Danneels.   

Abstract

OBJECTIVE: The first aim of this study was to determine the reliability of the Zebris (Achen, Germany) ultrasound-based testing of cervical range of motion (ROM). The second aim was to develop a normative database in a healthy sample of 96 volunteers. The third aim was to evaluate, with the Zebris system, the ROM in a sample of patients with chronic neck pain compared to healthy controls to determine if cervical ROM could discriminate between these groups and between subgroups of pain patients (with or without whiplash injury).
METHODS: The study participants were 96 healthy volunteers, 14 patients with idiopathic neck pain, and 16 patients with chronic whiplash. Cervical ROM was measured in the 3 planes with the Zebris CMS 70P ultrasound-based motion analysis system. The intra- and interrater reliability of the protocol was tested in 12 volunteers.
RESULTS: Full-cycle measurements showed high reliability (intraclass correlation coefficient, 0.80-0.94) with the SE of measurement ranging from 4.25 degrees to 7.88 degrees. The distribution of ROM measures showed a great individual variation, with a significant age-related decrease in ROM in all directions. Range of motion was reduced in patients with chronic whiplash in all primary movements, compared to healthy subjects, whereas in patients with idiopathic neck pain, only rotation showed reduced ROM.
CONCLUSION: Results demonstrate a high degree of test-retest reliability in measuring cervical ROM. The use of normative data for ROM when evaluating patients with neck disorders needs to take age into account. The current study has demonstrated that patients with chronic neck pain demonstrate reduced ROM, which differs between patients with idiopathic neck pain and those with chronic whiplash.

Entities:  

Mesh:

Year:  2007        PMID: 17693335     DOI: 10.1016/j.jmpt.2007.05.003

Source DB:  PubMed          Journal:  J Manipulative Physiol Ther        ISSN: 0161-4754            Impact factor:   1.437


  22 in total

1.  Neck range of motion measurements using a new three-dimensional motion analysis system: validity and repeatability.

Authors:  Haruhi Inokuchi; Michio Tojima; Hiroshi Mano; Yuki Ishikawa; Naoshi Ogata; Nobuhiko Haga
Journal:  Eur Spine J       Date:  2015-04-07       Impact factor: 3.134

2.  On the relevance of surrogate parameter deduction in biomedical research: mediated regression analysis for variance explanation of cervical range of motion.

Authors:  Daniel Niederer; Lutz Vogt; Jan Wilke; Winfried Banzer
Journal:  Eur Spine J       Date:  2016-06-21       Impact factor: 3.134

3.  Influence of movement speed on cervical range of motion.

Authors:  Bruno Bonnechère; Patrick Salvia; Pierre-Michel Dugailly; Laura Maroye; Bernard Van Geyt; Véronique Feipel
Journal:  Eur Spine J       Date:  2014-03-09       Impact factor: 3.134

4.  Age-related cutoffs for cervical movement behaviour to distinguish chronic idiopathic neck pain patients from unimpaired subjects.

Authors:  Daniel Niederer; Lutz Vogt; Jan Wilke; Marcus Rickert; Winfried Banzer
Journal:  Eur Spine J       Date:  2014-12-10       Impact factor: 3.134

5.  Task-specific frequencies of neck motion measured in healthy young adults over a five-day period.

Authors:  Daniel G Cobian; Andrew C Sterling; Paul A Anderson; Bryan C Heiderscheit
Journal:  Spine (Phila Pa 1976)       Date:  2009-03-15       Impact factor: 3.468

6.  Neck motion kinematics: an inter-tester reliability study using an interactive neck VR assessment in asymptomatic individuals.

Authors:  Hilla Sarig Bahat; Elliot Sprecher; Itamar Sela; Julia Treleaven
Journal:  Eur Spine J       Date:  2016-01-30       Impact factor: 3.134

7.  Reproducibility of the cervical range of motion (CROM) device for individuals with sub-acute whiplash associated disorders.

Authors:  Mark A Williams; Esther Williamson; Simon Gates; Matthew W Cooke
Journal:  Eur Spine J       Date:  2011-12-03       Impact factor: 3.134

8.  The effect of mind-body exercise on the cervical spine mobility of people with neck discomfort: A protocol for systematic review and meta-analysis.

Authors:  Xianhui Liao; Beihai Ge; Qiang Chen
Journal:  Medicine (Baltimore)       Date:  2021-06-04       Impact factor: 1.817

9.  Smartphone Applications as a Suitable Alternative to CROM Device and Inclinometers in Assessing the Cervical Range of Motion in Patients With Nonspecific Neck Pain.

Authors:  Faezeh Ghorbani; Mojtaba Kamyab; Fatemeh Azadinia
Journal:  J Chiropr Med       Date:  2020-09-03

10.  Kinematic measures during a clinical diagnostic technique for human neck disorder: inter- and intraexaminer comparisons.

Authors:  Joseph Vorro; Tamara R Bush; Brad Rutledge; Mingfei Li
Journal:  Biomed Res Int       Date:  2013-02-16       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.