Literature DB >> 17690431

A single-bead analysis on a disk-shaped microfluidic device using an antigen-immobilized bead.

Hidenori Nagai1, Yuka Narita, Miyuki Ohtaki, Keiitsu Saito, Shin-Ichi Wakida.   

Abstract

A disk-shaped microfluidic device (lab-on-a-Disk) was developed to allow the evaluation of mental stress. As a standard sample, secretory immunoglobulin A (sIgA), which is a candidate marker of mental stress, was measured by a heterogeneous enzyme immunoassay (EIA) on the lab-on-a-Disk. Centrifugal force provided a microfluidic control on the lab-on-a-Disk. We examined the relationship between the rotational speed, the channel profile, and the position of the microfluidic chambers from the center of rotation to manipulate sample solutions into each reaction reservoir through microchannels sequentially, i.e., retain in a reservoir or flow into a subsequent reservoir. A single glass bead with immobilized sIgA on its surface was injected into a reservoir for a competitive antigen-antibody reaction, and applied to a specific surface in a heterogeneous assay. It is expected that the lab-on-a-Disk would be suitable for miniaturization and automation of the processes in EIA compared with a conventional EIA using a titer plate.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17690431     DOI: 10.2116/analsci.23.975

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   2.081


  4 in total

1.  An enzyme-linked immunosorbent assay on a centrifugal platform using magnetic beads.

Authors:  Chih-Hsin Shih; Ho-Chin Wu; Chong-Yi Chang; Wen-Hong Huang; Yi-Feng Yang
Journal:  Biomicrofluidics       Date:  2014-09-19       Impact factor: 2.800

2.  Disk-based enzyme-linked immunosorbent assays using the liquid-aliquoting and siphoning-evacuation technique.

Authors:  Ho-Chin Wu; Yen-Hao Chen; Chih-Hsin Shih
Journal:  Biomicrofluidics       Date:  2018-09-13       Impact factor: 2.800

3.  Development of a Lab-on-a-Disk Platform with Digital Imaging for Identification and Counting of Parasite Eggs in Human and Animal Stool.

Authors:  Sertan Sukas; Bieke Van Dorst; Agata Kryj; Ole Lagatie; Wim De Malsche; Lieven J Stuyver
Journal:  Micromachines (Basel)       Date:  2019-12-05       Impact factor: 2.891

4.  Automated-immunosensor with centrifugal fluid valves for salivary cortisol measurement.

Authors:  Masaki Yamaguchi; Hiroki Katagata; Yuki Tezuka; Daisuke Niwa; Vivek Shetty
Journal:  Sens Biosensing Res       Date:  2014-07-09
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.