The application of a computerised videokeratography (CVK) based contact lens fitting software programme on irregularly shaped corneal surfaces.

Daniela S Nosch1, Gek L Ong, Ioannis Mavrikakis, Judith Morris.   

Abstract

PURPOSE: To explore the success of the application of a computerised videokeratography (CVK) software system for the fitting of rigid gas permeable (RGP) contact lenses (CLs) on irregular corneal surfaces and compare it to the standard diagnostic fitting procedure.
METHODS: This was a comparative prospective study, over a 1-year period (2004-2005). It included 41 RGP CL wearers (68 eyes) with irregular corneal surfaces. Of these, 51 (75%) had keratoconus, 7 (10%) corneal scarring (infectious or traumatic), 6 (6.82%) corneal transplants, 2 (2.9%) astigmatism, and 2 (2.9%) aphakia. Each eye was being re-fitted with a new RGP CL based on a topographical measurement in conjunction with a CL fitting software programme. The performance of the CLs was evaluated regarding visual outcome, fitting characteristics, and efficiency of the fitting procedure.
RESULTS: Of the 68 eyes, 53 (77.94%) chose the CL fitted using the CVK software system, 9 (13.24%) chose the CL fitted using the standard procedure, and 6 (8.82%) showed no preference for either CL. There was a statistically significant improvement regarding visual outcome [contrast sensitivity at the spatial frequencies of 0.66 (p=0.029), 3.40 (p=0.008), and 17 (p=0.032), subjective vision (p=0.009)], fitting characteristics [grading scale (p=0.00), lens comfort (p=0.00) and daily wearing time (p=0.002)], and efficiency [number of trial lenses required (p=0.00)] with the CL fitted using the CVK software system. Correlating factors for the likely preference for the CL fitted using the CVK software system were subjective vision (p=0.004), lens comfort (p=0.009), and convenience of the fitting procedure (p=0.023).
CONCLUSION: The application of a CVK software system for the fitting procedure of RGP CLs on irregular corneal surfaces was a safe procedure and shown to be more successful and efficient than the standard diagnostic fitting method.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17689133     DOI: 10.1016/j.clae.2007.06.003

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  4 in total

Review 1.  Nonsurgical Procedures for Keratoconus Management.

Authors:  L Rico-Del-Viejo; M Garcia-Montero; J L Hernández-Verdejo; S García-Lázaro; F J Gómez-Sanz; A Lorente-Velázquez
Journal:  J Ophthalmol       Date:  2017-12-21       Impact factor: 1.909

2.  Gas permeable contact lens fitting in keratoconus: Comparison of different guidelines to back optic zone radius calculations.

Authors:  Sara Ortiz-Toquero; Guadalupe Rodriguez; Victoria de Juan; Raul Martin
Journal:  Indian J Ophthalmol       Date:  2019-09       Impact factor: 1.848

3.  Initial Power of Rigid Gas Permeable Contact Lenses in Patients with Keratoconus.

Authors:  Fereshteh Birjandi; Hadi Ostadimoghaddam; Abbasali Yekta; Monireh Mahjoob
Journal:  J Curr Ophthalmol       Date:  2022-01-06

Review 4.  Contact lens in keratoconus.

Authors:  Varsha M Rathi; Preeji S Mandathara; Srikanth Dumpati
Journal:  Indian J Ophthalmol       Date:  2013-08       Impact factor: 1.848

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.