Literature DB >> 17683940

Digital goniometric measurement of knee joint motion. Evaluation of usefulness for research settings and clinical practice.

Berry Cleffken1, Gerard van Breukelen, Peter Brink, Henk van Mameren, Steven Olde Damink.   

Abstract

An accurate and reproducible measurement method for joint motion is essential for classification of success or failure in therapeutic intervention. Digital goniometry is increasingly used as a method of classification for knee joint excursion. The reliability of goniometry however remains debatable. Aim of the study was to determine both intra- and inter-rater reproducibility in degrees, with an electronic digital inclinometer (EDI 320) for active and passive maximum flexion and active maximum extension of the knee joint and to determine the reproducibility of active and passive range of motion. A classical crossover design, with strict measurement protocol was used. Two raters measured 72 knee motions each, in 42 healthy subjects in four sessions. The smallest detectable difference (SDD) was calculated by using adjusted Bland and Altman plots for each knee excursion. No differences in joint excursions between the sexes were found. Passive maximum flexion showed larger excursions than active maximum flexion with additional higher levels of reproducibility. SDDs for inter-rater comparisons yielded: 0+/-3.9 degrees for active maximum extension, 0+/-7.4 degrees for active maximum flexion, 0+/-6.4 degrees for passive maximum flexion, 0+/-7.6 degrees for AROM and 0+/-5.4 degrees for PROM. Intra-rater SDDs showed increased reproducibility by 0.4-1.9 degrees. We conclude that interpretation of knee joint excursions in clinical settings is with these SDDs. Clinical and statistical differences in research settings within these SDDs are not a true difference but should be attributed to measurement error.

Entities:  

Mesh:

Year:  2007        PMID: 17683940     DOI: 10.1016/j.knee.2007.07.004

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  13 in total

1.  Active knee range of motion assessment in elite track and field athletes: normative values.

Authors:  Nikos Malliaropoulos; Lena Kakoura; Kostas Tsitas; Dimitris Christodoulou; Alexandros Siozos; Peter Malliaras; Nicola Maffulli
Journal:  Muscles Ligaments Tendons J       Date:  2015-10-20

2.  Validity and reliability of using photography for measuring knee range of motion: a methodological study.

Authors:  Justine M Naylor; Victoria Ko; Sam Adie; Clive Gaskin; Richard Walker; Ian A Harris; Rajat Mittal
Journal:  BMC Musculoskelet Disord       Date:  2011-04-18       Impact factor: 2.362

3.  Reliability and accuracy of a goniometer mobile device application for video measurement of the functional movement screen deep squat test.

Authors:  David A Krause; Michael S Boyd; Allison N Hager; Eric C Smoyer; Anthony T Thompson; John H Hollman
Journal:  Int J Sports Phys Ther       Date:  2015-02

Review 4.  Efficacy and safety of home-based exercises versus individualized supervised outpatient physical therapy programs after total knee arthroplasty: a systematic review and meta-analysis.

Authors:  Mariano Florez-García; Fernando García-Pérez; Rafael Curbelo; Irene Pérez-Porta; Betina Nishishinya; Maria Piedad Rosario Lozano; Loreto Carmona
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-07-11       Impact factor: 4.342

5.  Measurement of the knee flexion angle with smartphone applications: Which technology is better?

Authors:  Jean-Yves Jenny; Abdullah Bureggah; Yann Diesinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-02-15       Impact factor: 4.342

6.  Validation of a dynamic joint contracture measuring device in a live rabbit model of arthrofibrosis.

Authors:  Nicolas Reina; William H Trousdale; Christopher G Salib; Loribeth Q Evertz; Lawrence J Berglund; Andre J van Wijnen; Timothy E Hewett; Charlotte E Berry; Daniel J Berry; Mark E Morrey; Joaquin Sanchez-Sotelo; Matthew P Abdel
Journal:  J Orthop Res       Date:  2018-02-23       Impact factor: 3.494

7.  Assessment of Correlation between Electrogoniometer Measurements and Sports-Specific Movement in Karate Elites.

Authors:  Sara Lotfian; Afsaneh Safar Cherati; Aliashraf Jamshidi; Mohammad Ali Sanjari
Journal:  Asian J Sports Med       Date:  2014-06

8.  Effect of Dynamic Balance Exercises Based on Visual Feedback on Physical Function, Balance Ability, and Depression in Women after Bilateral Total Knee Arthroplasty: A Randomized Controlled Trial.

Authors:  Ju-Yeon Lee; Jung-Hee Kim; Byoung-Hee Lee
Journal:  Int J Environ Res Public Health       Date:  2020-05-05       Impact factor: 3.390

9.  Reliability of radiographic measurements of knee motion following knee arthroplasty for use in a virtual knee clinic.

Authors:  A Phillips; A Goubran; S Naim; D Searle; V Mandalia; A Toms
Journal:  Ann R Coll Surg Engl       Date:  2012-10       Impact factor: 1.891

10.  Smartphone and Universal Goniometer for Measurement of Elbow Joint Motions: A Comparative Study.

Authors:  Behnam Behnoush; Nasim Tavakoli; Elham Bazmi; Fariborz Nateghi Fard; Mohammad Hossein Pourgharib Shahi; Arash Okazi; Tahmineh Mokhtari
Journal:  Asian J Sports Med       Date:  2016-06-11
View more