Literature DB >> 17664608

Experimental verification of magnetic field dose effects for the MRI-accelerator.

A J E Raaijmakers1, B W Raaymakers, J J W Lagendijk.   

Abstract

The MRI-linear accelerator system, currently being developed, is designed such that the patient is irradiated in the presence of a magnetic field. This influences the dose distribution due to the Lorentz force working on the secondary electrons. Simulations have shown that the following dose effects occur: the build-up distance is reduced, the lateral profile becomes asymmetric in the direction orthogonal to the magnetic field and at tissue-air interfaces the dose increases due to returning electrons. In this work, GafChromic film measurements were performed in the presence of a magnetic field to experimentally quantify these dose effects. Depth-dose curves were measured in a PMMA-air-PMMA phantom and the lateral profiles were measured in a homogeneous PMMA phantom with the photon beam protruding over the edges of the phantom. The measurement results confirmed the magnetic field dose effects that were predicted by simulations. This enabled us to verify Geant4 Monte Carlo simulations of these MRI-linac specific dose effects: the relative agreement for the depth-dose curves between measurements and simulations was within 2.2%/1.8 mm. The relative agreement for the lateral profiles was 2.3%/1.7 mm. Overall, the magnetic field dose effects that are expected for irradiation with the MRI-linac can be modelled using Geant4 Monte Carlo simulations within measurement accuracy.

Entities:  

Mesh:

Year:  2007        PMID: 17664608     DOI: 10.1088/0031-9155/52/14/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Feasibility of spinal stereotactic body radiotherapy in Elekta Unity® MR-Linac.

Authors:  Eun Young Han; Manik Aima; Neil Hughes; Tina M Briere; Debra N Yeboa; Pam Castillo; Jihong Wang; Jinzhong Yang; Sastry Vedam
Journal:  J Radiosurg SBRT       Date:  2020

Review 2.  Magnetic resonance image guidance in external beam radiation therapy planning and delivery.

Authors:  Ilamurugu Arivarasan; Chandrasekaran Anuradha; Shanmuga Subramanian; Ayyalusamy Anantharaman; Velayudham Ramasubramanian
Journal:  Jpn J Radiol       Date:  2017-06-13       Impact factor: 2.374

3.  Relative dosimetry with an MR-linac: Response of ion chambers, diamond, and diode detectors for off-axis, depth dose, and output factor measurements.

Authors:  Daniel J O'Brien; James Dolan; Stefan Pencea; Nicholas Schupp; Gabriel O Sawakuchi
Journal:  Med Phys       Date:  2017-12-21       Impact factor: 4.071

4.  On the accuracy of bulk synthetic CT for MR-guided online adaptive radiotherapy.

Authors:  Davide Cusumano; Lorenzo Placidi; Stefania Teodoli; Luca Boldrini; Francesca Greco; Silvia Longo; Francesco Cellini; Nicola Dinapoli; Vincenzo Valentini; Marco De Spirito; Luigi Azario
Journal:  Radiol Med       Date:  2019-10-08       Impact factor: 3.469

5.  Technical Note: A Monte Carlo study of magnetic-field-induced radiation dose effects in mice.

Authors:  Ashley E Rubinstein; Zhongxing Liao; Adam D Melancon; Michele Guindani; David S Followill; Ramesh C Tailor; John D Hazle; Laurence E Court
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

6.  Optical imaging method to quantify spatial dose variation due to the electron return effect in an MR-linac.

Authors:  Jacqueline M Andreozzi; Petr Brůža; Jochen Cammin; Brian W Pogue; David J Gladstone; Olga Green
Journal:  Med Phys       Date:  2019-12-25       Impact factor: 4.071

7.  Normal lung tissue complication probability in MR-Linac and conventional radiotherapy.

Authors:  Somayeh Gholami; Francesco Longo; Sara Shahzadeh; Hassan Ali Nedaie; Ryan Sharp; Ali S Meigooni
Journal:  Rep Pract Oncol Radiother       Date:  2020-09-29

8.  Characterization of the effect of MRI on Gafchromic film dosimetry.

Authors:  Meral L Reyhan; Ting Chen; Miao Zhang
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

Review 9.  The potential for an enhanced role for MRI in radiation-therapy treatment planning.

Authors:  P Metcalfe; G P Liney; L Holloway; A Walker; M Barton; G P Delaney; S Vinod; W Tome
Journal:  Technol Cancer Res Treat       Date:  2013-04-24

10.  Treating locally advanced lung cancer with a 1.5T MR-Linac - Effects of the magnetic field and irradiation geometry on conventionally fractionated and isotoxic dose-escalated radiotherapy.

Authors:  Hannah E Bainbridge; Martin J Menten; Martin F Fast; Simeon Nill; Uwe Oelfke; Fiona McDonald
Journal:  Radiother Oncol       Date:  2017-10-04       Impact factor: 6.280

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.