Amorphous silicon EPID calibration for dosimetric applications: comparison of a method based on Monte Carlo prediction of response with existing techniques.

L Parent1, A L Fielding, D R Dance, J Seco, P M Evans.   

Abstract

For EPID dosimetry, the calibration should ensure that all pixels have a similar response to a given irradiation. A calibration method (MC), using an analytical fit of a Monte Carlo simulated flood field EPID image to correct for the flood field image pixel intensity shape, was proposed. It was compared with the standard flood field calibration (FF), with the use of a water slab placed in the beam to flatten the flood field (WS) and with a multiple field calibration where the EPID was irradiated with a fixed 10x10 field for 16 different positions (MF). The EPID was used in its normal configuration (clinical setup) and with an additional 3 mm copper slab (modified setup). Beam asymmetry measured with a diode array was taken into account in MC and WS methods. For both setups, the MC method provided pixel sensitivity values within 3% of those obtained with the MF and WS methods (mean difference<1%, standard deviation<2%). The difference of pixel sensitivity between MC and FF methods was up to 12.2% (clinical setup) and 11.8% (modified setup). MC calibration provided images of open fields (5x5 to 20x20 cm2) and IMRT fields to within 3% of that obtained with WS and MF calibrations while differences with images calibrated with the FF method for fields larger than 10x10 cm2 were up to 8%. MC, WS and MF methods all provided a major improvement on the FF method. Advantages and drawbacks of each method were reviewed.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17664548     DOI: 10.1088/0031-9155/52/12/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  Transit dosimetry in dynamic IMRT with an a-Si EPID.

Authors:  Mahsheed Sabet; Pejman Rowshanfarzad; Fred W Menk; Peter B Greer
Journal:  Med Biol Eng Comput       Date:  2014-05-31       Impact factor: 2.602

Review 2.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

3.  Testing the portal imager GLAaS algorithm for machine quality assurance.

Authors:  G Nicolini; E Vanetti; A Clivio; A Fogliata; G Boka; L Cozzi
Journal:  Radiat Oncol       Date:  2008-05-21       Impact factor: 3.481

4.  A quality assurance phantom for electronic portal imaging devices.

Authors:  Indra J Das; Minsong Cao; Chee-Wai Cheng; Vladimir Misic; Klaus Scheuring; Edmund Schüle; Peter A S Johnstone
Journal:  J Appl Clin Med Phys       Date:  2011-02-02       Impact factor: 2.102

5.  EPID dosimetry for pretreatment quality assurance with two commercial systems.

Authors:  Daniel W Bailey; Lalith Kumaraswamy; Mohammad Bakhtiari; Harish K Malhotra; Matthew B Podgorsak
Journal:  J Appl Clin Med Phys       Date:  2012-07-05       Impact factor: 2.102

6.  Normalize the response of EPID in pursuit of linear accelerator dosimetry standardization.

Authors:  Bin Cai; S Murty Goddu; Sridhar Yaddanapudi; Douglas Caruthers; Jie Wen; Camille Noel; Sasa Mutic; Baozhou Sun
Journal:  J Appl Clin Med Phys       Date:  2017-11-10       Impact factor: 2.102

7.  Determination of the electronic portal imaging device pixel-sensitivity-map for quality assurance applications. Part 2: Photon beam dependence.

Authors:  Michael Paul Barnes; Baozhou Sun; Brad Michael Oborn; Bishnu Lamichhane; Stuart Szwec; Matthew Schmidt; Bin Cai; Frederick Menk; Peter Greer
Journal:  J Appl Clin Med Phys       Date:  2022-04-15       Impact factor: 2.243

8.  The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy.

Authors:  Giorgia Nicolini; Eugenio Vanetti; Alessandro Clivio; Antonella Fogliata; Stine Korreman; Jiri Bocanek; Luca Cozzi
Journal:  Radiat Oncol       Date:  2008-09-09       Impact factor: 3.481

9.  Calibration of a detector array through beam profile reconstruction with error-locking.

Authors:  Song Wang; Zhiqiu Li; K S Clifford Chao; Jenghwa Chang
Journal:  J Appl Clin Med Phys       Date:  2014-11-08       Impact factor: 2.102

10.  An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm.

Authors:  Hashemi S M; Bahreyni M H; Mohammadi M; Nasseri S; Bayani S; Gholamhosseinian H; Salek R; Shahedi F; Momennezhad M
Journal:  J Biomed Phys Eng       Date:  2019-10-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.