Use of GAFCHROMIC XR type R films for skin-dose measurements in interventional radiology: Validation of a dosimetric procedure on a sample of patients undergone interventional cardiology.

S Delle Canne1, A Carosi, A Bufacchi, T Malatesta, R Capperella, R Fragomeni, N Adorante, S Bianchi, L Begnozzi.   

Abstract

The Gafchromic XR type R film is a suitable dosimeter to determine the map of the skin dose in patients undergone complex interventional radiological procedures, such as cardiology ones. The need of preventing or locating possible skin injuries due to high doses administered to patients-as recommended by international organizations-wants the introduction in patient dosimetry of a dosimeter easy to handle, with low dependence of the response on energy in the typical radiological range, and extended measurable dose range. XR type R films fulfil all these requirements and moreover may be quickly analyzed by cheap commercial scanners. In order to determine skin-dose values by XR-R, a film calibration curve is required. In this work, validation of the XR-R dosimetry has been performed for the determination of the skin dose: maximum skin-dose values in 14 patients undergone radiofrequency ablation and pacemaker implant procedures have been determined by XR-R calibrated films. A comparison between skin-dose values determined by XR-R films and retrospective ionometric measurements has pointed out some discrepancies in the results, due to difficulties in retrospectively reproducing the real procedure settings, where XR-R film dosimetry is related to the specific patient procedure, even, in very complex interventional settings.

Entities:  

Year:  2006        PMID: 17664156     DOI: 10.1016/S1120-1797(06)80004-9

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  4 in total

1.  Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner.

Authors:  Bradley P McCabe; Michael A Speidel; Tina L Pike; Michael S Van Lysel
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

2.  How accurately can the peak skin dose in fluoroscopy be determined using indirect dose metrics?

Authors:  A Kyle Jones; Joe E Ensor; Alexander S Pasciak
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

3.  Patient radiation doses in interventional cardiology procedures.

Authors:  Ioannis Pantos; Georgios Patatoukas; Demosthenes G Katritsis; Efstathios Efstathopoulos
Journal:  Curr Cardiol Rev       Date:  2009-01

4.  Dose evaluation for skin and organ in hepatocellular carcinoma during angiographic procedure.

Authors:  Daniela D'Alessio; Claudia Giliberti; Antonella Soriani; Livio Carpanese; Giuseppe Pizzi; Giulio Vallati; Lidia Strigari
Journal:  J Exp Clin Cancer Res       Date:  2013-10-25
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.