Literature DB >> 17662163

In vivo ultrasound real-time motion of the cervical spine during intubation under manual in-line stabilization: a comparison of intubation methods.

E Gercek1, B M Wahlen, P M Rommens.   

Abstract

BACKGROUND AND
OBJECTIVE: In emergency trauma situations, manual in-line stabilization of the cervical spine is recommended to reduce cervical spine movement during intubation. The aim of this study was to compare the effect of manual in-line stabilization during different intubation techniques on three-dimensional cervical spine movements and times to intubation.
METHODS: Forty-eight subjects without any history of trauma, inflammatory or degenerative disorder of the cervical spine were randomly grouped, regardless of gender or age. All underwent elective surgery under general anaesthesia. Under manual in-line stabilization, laryngeal intubation with Macintosh laryngoscope, intubating laryngeal mask airway, fibre-endoscopic oral intubation and fibre-endoscopic nasal intubation was performed. During the intubation process, cervical three-dimensional motion was detected by an ultrasound real-time motion analysis system and intubation times were measured.
RESULTS: Cervical spine range in the extension/flexion direction of orolaryngeal intubation with Macintosh (17.57 +/- 8.23 degrees ) showed significantly more movement than using the intubating laryngeal mask airway (4.60 +/- 1.51 degrees ) and fibreoptic procedures. Intubating laryngeal mask airway was significantly different than the fibreoptic intubation techniques. There was also a significant difference between oral (3.61 +/- 2.25 degrees ) nasal and (5.88 +/- 3.11 degrees ) fibreoptic intubation. Times to intubation all differed significantly (P < 0.05) for the Macintosh laryngoscope (27.25 +/- 8.56 s) and for the intubating laryngeal mask airway (16.5 +/- 9.76 s). Fibreendoscopic laryngoscopic oral (52.91 +/- 56.27 s) and nasal (82.32 +/- 54.06 s) intubation resulted in further prolongation of the times to intubation.
CONCLUSIONS: The intubating laryngeal mask airway with manual in-line stabilization is a potentially useful adjunct to intubation of patients with potential cervical spine injury, if there are no contraindications to these methods. These results predict that fibreoptic procedures may be a safe instrument for airway management in patients with potential cervical spine injuries; however, the main disadvantages are the longer intubation times.

Entities:  

Mesh:

Year:  2007        PMID: 17662163     DOI: 10.1017/S0265021507001044

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  6 in total

Review 1.  Ultrasound diagnosis and therapeutic intervention in the spine.

Authors:  Adil S Ahmed; Raahul Ramakrishnan; Vignesh Ramachandran; Shyam S Ramachandran; Kevin Phan; Erik L Antonsen
Journal:  J Spine Surg       Date:  2018-06

2.  Fluoroscopic Comparison of Cervical Spine Motion Using LMA CTrach, C-MAC Videolaryngoscope and Macintosh Laryngoscope.

Authors:  Tülay Şahin; Zehra İpek Arslan; Gür Akansel; Onur Balaban; Derya Berk; Mine Solak; Kamil Toker
Journal:  Turk J Anaesthesiol Reanim       Date:  2018-02-01

3.  Neurological deterioration during intubation in cervical spine disorders.

Authors:  Padmaja Durga; Barada Prasad Sahu
Journal:  Indian J Anaesth       Date:  2014 Nov-Dec

Review 4.  Alternative intubation techniques vs Macintosh laryngoscopy in patients with cervical spine immobilization: systematic review and meta-analysis of randomized controlled trials.

Authors:  L Suppan; M R Tramèr; M Niquille; O Grosgurin; C Marti
Journal:  Br J Anaesth       Date:  2015-06-30       Impact factor: 9.166

5.  Airway Management with Cervical Spine Immobilisation: A Comparison between the Macintosh Laryngoscope, Truview Evo2, and Totaltrack VLM Used by Novices--A Manikin Study.

Authors:  Dawid Aleksandrowicz; Tomasz Gaszyński
Journal:  Biomed Res Int       Date:  2016-02-29       Impact factor: 3.411

6.  Comparison of Videolaryngoscope and Intubating Laryngeal Mask Airway for Tracheal Intubation with Manual-in-line Stabilization in Patients Undergoing Cervical Spine Surgery.

Authors:  Reena Jakhar; Deepti Saigal; Suniti Kale; Shipra Aggarwal
Journal:  Anesth Essays Res       Date:  2020-11-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.