The compensation of perturbing temperature fluctuation in glucose monitoring technologies based on impedance spectroscopy.

Daniel Huber1, Mark Talary, François Dewarrat, Andreas Caduff.   

Abstract

Non-invasive glucose monitoring techniques based on impedance spectroscopy are affected by a variety of perturbing effects. In order to use the impedance as a glucose measure, these perturbing effects need to be quantified and compensated. Since effects induced by temperature fluctuations certainly rank among the severest perturbations, a clinical study was carried out to establish whether temperature, as a perturbing factor, could be compensated for in impedance spectroscopy. The results as well as a concept allowing for the compensation of perturbing temperature fluctuations are presented here. The compensation technique described is a generic approach that, in principle, can be applied to compensate most perturbation effects provided that there are now multiplicative interactions between the variable of interest (in our case the glucose) and the perturbations. The results allow for the determination of the minimum required sensitivity of an impedance spectrometer to glucose in order to be operational in home-use conditions. Furthermore, the data can be used to estimate if a universal temperature compensation can be applied or if an individual calibration is necessary. For instance, applying a universal temperature compensation and requiring an application range of +/-5 degrees C, the minimum required sensitivity of the minimum impedance and frequency in a sensor-skin RLC circuit to resolve glucose variations equivalent to 10 mg/dl is 0.85 Omega/mg/dl and 0.14 MHz/mg/dl, respectively. The sensitivity requirements reduce by about a factor 1.6, if for each subject an individual calibration is carried out. Depending on the measure and the calibration procedure, the required sensitivities are a factor 3-50 greater than those reported in the literature. Thus, in order to be operational in home-use conditions, the signal-to-noise ratio (S/N) of existing impedance-based monitoring platforms using RLC circuits need to be improved by about one order of magnitude. In order to make non-invasive glucose monitoring possible we, therefore, suggest some measures that may improve the S/N by the required factor.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17661101     DOI: 10.1007/s11517-007-0229-3

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  23 in total

1.  A quantitative approach to the dielectric properties of the skin.

Authors:  V Raicu; N Kitagawa; A Irimajiri
Journal:  Phys Med Biol       Date:  2000-02       Impact factor: 3.609

2.  Impact of posture and fixation technique on impedance spectroscopy used for continuous and noninvasive glucose monitoring.

Authors:  Andreas Pfützner; Andreas Caduff; Martin Larbig; Thomas Schrepfer; Thomas Forst
Journal:  Diabetes Technol Ther       Date:  2004-08       Impact factor: 6.118

3.  The effect of ambient air temperature on whole-body bioelectrical impedance.

Authors:  Michael J Buono; Sean Burke; Sarah Endemann; Heidi Graham; Christel Gressard; Lisa Griswold; Betty Michalewicz
Journal:  Physiol Meas       Date:  2004-02       Impact factor: 2.833

Review 4.  Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium.

Authors:  Omar S Khalil
Journal:  Diabetes Technol Ther       Date:  2004-10       Impact factor: 6.118

Review 5.  Insulin-induced vasodilatation: physiology or pharmacology?

Authors:  H Yki-Järvinen; T Utriainen
Journal:  Diabetologia       Date:  1998-04       Impact factor: 10.122

6.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues.

Authors:  S Gabriel; R W Lau; C Gabriel
Journal:  Phys Med Biol       Date:  1996-11       Impact factor: 3.609

7.  Comments on 'dielectric properties of the skin'.

Authors:  C Gabriel
Journal:  Phys Med Biol       Date:  1997-08       Impact factor: 3.609

Review 8.  The passive electrical properties of biological systems: their significance in physiology, biophysics and biotechnology.

Authors:  R Pethig; D B Kell
Journal:  Phys Med Biol       Date:  1987-08       Impact factor: 3.609

9.  Non-invasive glycaemia blood measurements by electromagnetic sensor: study in static and dynamic blood circulation.

Authors:  M Gourzi; A Rouane; R Guelaz; M S Alavi; M B McHugh; M Nadi; P Roth
Journal:  J Med Eng Technol       Date:  2005 Jan-Feb

10.  Impact of environmental temperature on skin thickness and microvascular blood flow in subjects with and without diabetes.

Authors:  T Forst; A Caduff; M Talary; M Weder; M Brändle; P Kann; F Flacke; Ch Friedrich; A Pfützner
Journal:  Diabetes Technol Ther       Date:  2006-02       Impact factor: 6.118

View more
  4 in total

Review 1.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

2.  Multi-objective blood glucose control for type 1 diabetes.

Authors:  Pinky Dua; Francis J Doyle; Efstratios N Pistikopoulos
Journal:  Med Biol Eng Comput       Date:  2009-02-13       Impact factor: 2.602

Review 3.  Review of Non-invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone.

Authors:  Maryamsadat Shokrekhodaei; Stella Quinones
Journal:  Sensors (Basel)       Date:  2020-02-25       Impact factor: 3.576

4.  Temperature Correction to Enhance Blood Glucose Monitoring Accuracy Using Electrical Impedance Spectroscopy.

Authors:  Ye Sung Lee; Minkook Son; Alexander Zhbanov; Yugyung Jung; Myoung Hoon Jung; Kunsun Eom; Sung Hyun Nam; Jongae Park; Sung Yang
Journal:  Sensors (Basel)       Date:  2020-10-31       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.