Literature DB >> 15764378

Non-invasive glycaemia blood measurements by electromagnetic sensor: study in static and dynamic blood circulation.

M Gourzi1, A Rouane, R Guelaz, M S Alavi, M B McHugh, M Nadi, P Roth.   

Abstract

In this paper, we present the results of non-invasive blood glycaemia measurements. The blood used in the measurements was calf blood. The measurement method uses an electromagnetic sensor based on eddy currents, which allows the detection of blood glycaemia levels through the variation of the dielectric parameters of the blood. A change in blood glucose concentration causes a variation in the dielectric parameters, in particular conductivity. Detection is only possible at a resonant frequency. The measurements were taken in a static and dynamic state (with and without circulation of blood). The blood is inside a plastic tube placed within the sensor and is surrounded by gelatine, which simulates muscular tissue. The plastic tube simulates the vein where blood circulation occurs. The in vitro results in both cases (static and dynamic) are provided. Under unfavourable conditions we can detect a change of +/- 2 g/l of glucose. We present and discuss these results.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15764378     DOI: 10.1080/03091900410001720247

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  11 in total

Review 1.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

2.  The compensation of perturbing temperature fluctuation in glucose monitoring technologies based on impedance spectroscopy.

Authors:  Daniel Huber; Mark Talary; François Dewarrat; Andreas Caduff
Journal:  Med Biol Eng Comput       Date:  2007-07-28       Impact factor: 2.602

Review 3.  Noninvasive Blood Glucose Monitoring Systems Using Near-Infrared Technology-A Review.

Authors:  Aminah Hina; Wala Saadeh
Journal:  Sensors (Basel)       Date:  2022-06-27       Impact factor: 3.847

Review 4.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

5.  Recent advances in noninvasive glucose monitoring.

Authors:  Chi-Fuk So; Kup-Sze Choi; Thomas Ks Wong; Joanne Wy Chung
Journal:  Med Devices (Auckl)       Date:  2012-06-29

6.  A low frequency electromagnetic sensor for indirect measurement of glucose concentration: in vitro experiments in different conductive solutions.

Authors:  Andrea Tura; Stefano Sbrignadello; Domenico Cianciavicchia; Giovanni Pacini; Paolo Ravazzani
Journal:  Sensors (Basel)       Date:  2010-05-28       Impact factor: 3.576

7.  Rapid, sensitive, and reusable detection of glucose by a robust radiofrequency integrated passive device biosensor chip.

Authors:  Nam-Young Kim; Kishor Kumar Adhikari; Rajendra Dhakal; Zorigt Chuluunbaatar; Cong Wang; Eun-Soo Kim
Journal:  Sci Rep       Date:  2015-01-15       Impact factor: 4.379

Review 8.  Fiber Optic Sensors: A Review for Glucose Measurement.

Authors:  José Luis Cano Perez; Jaime Gutiérrez-Gutiérrez; Christian Perezcampos Mayoral; Eduardo L Pérez-Campos; Maria Del Socorro Pina Canseco; Lorenzo Tepech Carrillo; Laura Pérez-Campos Mayoral; Marciano Vargas Treviño; Edmundo López Apreza; Roberto Rojas Laguna
Journal:  Biosensors (Basel)       Date:  2021-02-25

Review 9.  Italian contributions to the development of continuous glucose monitoring sensors for diabetes management.

Authors:  Giovanni Sparacino; Mattia Zanon; Andrea Facchinetti; Chiara Zecchin; Alberto Maran; Claudio Cobelli
Journal:  Sensors (Basel)       Date:  2012-10-12       Impact factor: 3.576

10.  Sodium concentration measurement during hemodialysis through ion-exchange resin and conductivity measure approach: in vitro experiments.

Authors:  Andrea Tura; Stefano Sbrignadello; Emanuele Mambelli; Paolo Ravazzani; Antonio Santoro; Giovanni Pacini
Journal:  PLoS One       Date:  2013-07-02       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.