Literature DB >> 17659364

Results, experience and technical points learnt with use of the SKy Bone Expander kyphoplasty system for osteoporotic vertebral compression fractures: a prospective study of 40 patients with a minimum of 12 months of follow-up.

Leon Siang Shen Foo1, William Yeo, Stephanie Fook, Chang Ming Guo, John Li Tat Chen, Wai Mun Yue, Seang Beng Tan.   

Abstract

To describe our centre's results, experience and technical points learnt with the SKy Bone Expander System for osteoporotic vertebral compression fractures (VCFs). Forty consecutive patients with painful single level T12 or L1 osteoporotic VCF who had failed conservative management for more than 3 months had 40 single level SKy Bone Expander kyphoplasties performed. Using local anaesthesia with patients in a prone, hyper-lordotic position, a unilateral, percutaneous, intra-pedicular approach was employed. Once correctly positioned, the SKy Bone Expander was expanded, creating a void. It was subsequently contracted, removed and bone cement injected. Pre-kyphoplasty and 12-month post-kyphoplasty radiological and functional outcomes were recorded. Statistical analysis was by Wilcoxon Signed Ranks Test. Median percentage increase in anterior, middle and posterior vertebral body heights at 12-month post-operative was 51.25% [inter-quartile range (IQR) 17.21-93.22], 52.29% (IQR 26.50-126.17) and 9.84% (IQR 4.94-19.26) respectively, while median percentage decrease in kyphotic angle was 30.77% (IQR 17.06-46.61). There was no significant vertebral body correction loss at 12-month post-operative. Visual analogue score, North American Spine Society and Short Form-36 scores for physical functioning and bodily pain scores improved by medians of 5.0 (IQR 3.0-8.0), 1.45 (IQR 0.68-2.90), 20.5 (IQR 0.0-40.8) and 10.0 (IQR 0.0-20.0) respectively. All P-values were <0.001. There were eight adjacent/remote level VCFs, three cases of cement extravasation and one case of the SKy Bone Expander being unable to be contracted and withdrawn from the vertebral body. It was left in situ. This is the first reported incidence of such a complication. The SKy Bone Expander System appears to be a viable alternative to balloon tamp kyphoplasty. Important technical considerations include proper device positioning within the vertebral body before expansion, single use of devices, familiarity with salvage procedure and injection of bone cement under close image intensifier guidance to prevent cement extravasation.

Entities:  

Mesh:

Year:  2007        PMID: 17659364      PMCID: PMC2223354          DOI: 10.1007/s00586-007-0438-3

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  23 in total

1.  [CT-based analysis of cement distribution in unipedicular vertebroplasty].

Authors:  M Walz; E Esmer; B Kolbow
Journal:  Unfallchirurg       Date:  2006-11       Impact factor: 1.000

2.  Defining incident vertebral deformity: a prospective comparison of several approaches. The Study of Osteoporotic Fractures Research Group.

Authors:  D M Black; L Palermo; M C Nevitt; H K Genant; L Christensen; S R Cummings
Journal:  J Bone Miner Res       Date:  1999-01       Impact factor: 6.741

3.  Incidence of adjacent vertebral fractures in patients treated with balloon kyphoplasty: two years' prospective follow-up.

Authors:  R Pflugmacher; R-J Schroeder; C K Klostermann
Journal:  Acta Radiol       Date:  2006-10       Impact factor: 1.990

4.  Balloon kyphoplasty for vertebral compression fracture using a unilateral balloon tamp via a uni-pedicular approach: technical note.

Authors:  Brian L Hoh; James D Rabinov; Johnny C Pryor; Joshua A Hirsch
Journal:  Pain Physician       Date:  2004-01       Impact factor: 4.965

5.  Biomechanical comparison of unipedicular versus bipedicular kyphoplasty.

Authors:  John Steinmann; Craig T Tingey; Gina Cruz; Qian Dai
Journal:  Spine (Phila Pa 1976)       Date:  2005-01-15       Impact factor: 3.468

Review 6.  Balloon kyphoplasty and vertebroplasty for vertebral compression fractures: a comparative systematic review of efficacy and safety.

Authors:  Rod S Taylor; Rebecca J Taylor; Peter Fritzell
Journal:  Spine (Phila Pa 1976)       Date:  2006-11-01       Impact factor: 3.468

7.  Vertebroplasty: cement leakage into the disc increases the risk of new fracture of adjacent vertebral body.

Authors:  Edward P Lin; Sven Ekholm; Akio Hiwatashi; Per-Lennart Westesson
Journal:  AJNR Am J Neuroradiol       Date:  2004-02       Impact factor: 3.825

8.  Primary and secondary osteoporosis' incidence of subsequent vertebral compression fractures after kyphoplasty.

Authors:  James S Harrop; Bronco Prpa; Mary Kay Reinhardt; Isador Lieberman
Journal:  Spine (Phila Pa 1976)       Date:  2004-10-01       Impact factor: 3.468

Review 9.  Minimally invasive treatments of osteoporotic vertebral compression fractures.

Authors:  Frank M Phillips
Journal:  Spine (Phila Pa 1976)       Date:  2003-08-01       Impact factor: 3.468

10.  Health-related quality of life and radiographic vertebral fracture.

Authors:  W Cockerill; M Lunt; A J Silman; C Cooper; P Lips; A K Bhalla; J B Cannata; R Eastell; D Felsenberg; C Gennari; O Johnell; J A Kanis; C Kiss; P Masaryk; M Naves; G Poor; H Raspe; D M Reid; J Reeve; J Stepan; C Todd; A D Woolf; T W O'Neill
Journal:  Osteoporos Int       Date:  2003-11-13       Impact factor: 4.507

View more
  4 in total

1.  [Kyphoplasty in the treatment of osteoporotic spine fractures. Experience in over 500 patients].

Authors:  A Prokop; C Koukal; R Dolezych; M Chmielnicki
Journal:  Z Gerontol Geriatr       Date:  2012-12       Impact factor: 1.281

Review 2.  [Biomechanical aspects of vertebral augmentation].

Authors:  H-J Wilke
Journal:  Unfallchirurg       Date:  2015-10       Impact factor: 1.000

3.  [Kyphoplasty in osteoporotic spinal fractures].

Authors:  A Prokop; F Löhlein; M Chmilniecki; J Volbracht; M Manner
Journal:  Unfallchirurg       Date:  2010-02       Impact factor: 1.000

4.  Percutaneous intervertebral bridging cementoplasty for adjacent multilevel osteoporotic thoracolumbar fractures with vertebral endplate-disc complex injury: technical note.

Authors:  Song Wang; Chunyan Duan; Han Yang; Jianping Kang; Qing Wang
Journal:  Sci Rep       Date:  2020-09-01       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.