Evaluation of two commercially available anti human immunodeficiency virus antibody ELISA Kits using clinical samples.

K Anuradha1, S P D Ponamgi, V Lakshmi.   

Abstract

Laboratory diagnosis is the mainstay in the diagnosis of HIV infection in an individual. The wide range of diagnostic kits available, for the detection of anti HIV antibodies, makes it mandatory that the kits are evaluated before they are made available in the market. We evaluated the performance of a Microlisa HIV kit (J. Mitra & Co.) using a panel of HIV reactive and non reactive clinical specimens. The sensitivity and specificity of the kit were found to be 100% as compared to the UBI HIV 1/2 EIA kit. The ease of testing, the assay characteristics including efficiency of the Microlisa favour its use by laboratories as a primary screen for HIV infection.

Entities:  

Year:  2002        PMID: 17657043

Source DB:  PubMed          Journal:  Indian J Med Microbiol        ISSN: 0255-0857            Impact factor:   0.985


  1 in total

1.  Extensive tests for extermination: Need for incorporation of molecular detection methods of human immunodeficiency virus in screening algorithm in tertiary hospitals in India.

Authors:  Priya Singh; Ruchita Tyagi; Surjit Singh; Aman Sharma; Ritu Aggarwal; Ranjana W Minz
Journal:  Indian J Sex Transm Dis AIDS       Date:  2019 Jul-Dec
  1 in total