Literature DB >> 17654574

Applications and limitations of whole-brain MAGIC VASO functional imaging.

A Scouten1, R T Constable.   

Abstract

This work extends the multiple acquisitions with global inversion cycling vascular space occupancy (MAGIC VASO) method to human whole-brain functional magnetic resonance imaging (fMRI) at 3.0 Tesla and demonstrates the need to consider the dynamic contribution of cerebrospinal fluid (CSF) to the relative VASO signal change (DeltaVASO/VASO). Simulations were performed to determine the optimal slice number between global inversions, and correction factors were obtained to account for incomplete blood nulling in particular slices. The necessity of an accurate estimate of resting cerebral blood volume (CBV(rest)) is discussed in the context of DeltaCBV/CBV calculations. A three-compartment model is proposed to include both the resting and changing fractional CSF contribution (x(c,rest) and Deltax(c), respectively) to DeltaVASO/VASO. A MAGIC VASO sequence that provides whole-brain coverage is demonstrated using a paradigm comprised of visual, motor, and auditory stimulation. Activated regions are quantitatively compared in the corresponding blood oxygenation level-dependent (BOLD) images. Estimates of the minimum DeltaCBV/CBV resulting from motor and visual stimulation were comparable to previous findings at 17 +/- 8% (N = 8) and 19 +/- 9% (N = 6), respectively. The absence of VASO activation for auditory stimulation and evidence of activation-induced decreases in CSF volume fraction around the insula and superior temporal gyrus support the possibility of a Deltax(c) contribution to the VASO signal. Without specific knowledge of the CSF components (x(c,rest) and Deltax(c)), inference of DeltaCBV/CBV from DeltaVASO/VASO is severely limited.

Entities:  

Mesh:

Year:  2007        PMID: 17654574      PMCID: PMC2673534          DOI: 10.1002/mrm.21273

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Intervoxel heterogeneity of event-related functional magnetic resonance imaging responses as a function of T(1) weighting.

Authors:  Hanzhang Lu; Xavier Golay; Peter C M van Zijl
Journal:  Neuroimage       Date:  2002-10       Impact factor: 6.556

2.  Brain incorporation of [11C]arachidonic acid in young healthy humans measured with positron emission tomography.

Authors:  Giampiero Giovacchini; Michael C J Chang; Michael A Channing; Maria Toczek; Alicja Mason; Arun L W Bokde; Catherine Connolly; Bik-Kee Vuong; Ying Ma; Margaret G Der; Doris J Doudet; Peter Herscovitch; William C Eckelman; Stanley I Rapoport; Richard E Carson
Journal:  J Cereb Blood Flow Metab       Date:  2002-12       Impact factor: 6.200

3.  Comparison of multi-echo spiral and echo planar imaging in functional MRI.

Authors:  Markus Klarhöfer; Markus Barth; Ewald Moser
Journal:  Magn Reson Imaging       Date:  2002-05       Impact factor: 2.546

4.  Multiple acquisitions with global inversion cycling (MAGIC): a multislice technique for vascular-space-occupancy dependent fMRI.

Authors:  Hanzhang Lu; Peter C M van Zijl; Jeroen Hendrikse; Xavier Golay
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

5.  Sustained poststimulus elevation in cerebral oxygen utilization after vascular recovery.

Authors:  Hanzhang Lu; Xavier Golay; James J Pekar; Peter C M Van Zijl
Journal:  J Cereb Blood Flow Metab       Date:  2004-07       Impact factor: 6.200

6.  Spatial resolution, signal-to-noise ratio, and smoothing in multi-subject functional MRI studies.

Authors:  A Scouten; X Papademetris; R T Constable
Journal:  Neuroimage       Date:  2005-12-15       Impact factor: 6.556

7.  Functional mapping of the human visual cortex by magnetic resonance imaging.

Authors:  J W Belliveau; D N Kennedy; R C McKinstry; B R Buchbinder; R M Weisskoff; M S Cohen; J M Vevea; T J Brady; B R Rosen
Journal:  Science       Date:  1991-11-01       Impact factor: 47.728

8.  Oxygenation-sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields.

Authors:  S Ogawa; T M Lee; A S Nayak; P Glynn
Journal:  Magn Reson Med       Date:  1990-04       Impact factor: 4.668

9.  Assessment of hemodynamic response during focal neural activity in human using bolus tracking, arterial spin labeling and BOLD techniques.

Authors:  T Q Li; T N Haefelin; B Chan; A Kastrup; T Jonsson; G H Glover; M E Moseley
Journal:  Neuroimage       Date:  2000-10       Impact factor: 6.556

10.  Changes in human cerebral blood flow and cerebral blood volume during hypercapnia and hypocapnia measured by positron emission tomography.

Authors:  Hiroshi Ito; Iwao Kanno; Masanobu Ibaraki; Jun Hatazawa; Shuichi Miura
Journal:  J Cereb Blood Flow Metab       Date:  2003-06       Impact factor: 6.200

View more
  17 in total

1.  Application of whole-brain CBV-weighted fMRI to a cognitive stimulation paradigm: robust activation detection in a stroop task experiment using 3D GRASE VASO.

Authors:  Benedikt A Poser; David G Norris
Journal:  Hum Brain Mapp       Date:  2010-06-24       Impact factor: 5.038

2.  Three-dimensional acquisition of cerebral blood volume and flow responses during functional stimulation in a single scan.

Authors:  Ying Cheng; Peter C M van Zijl; James J Pekar; Jun Hua
Journal:  Neuroimage       Date:  2014-08-23       Impact factor: 6.556

Review 3.  IRON fMRI measurements of CBV and implications for BOLD signal.

Authors:  Joseph B Mandeville
Journal:  Neuroimage       Date:  2012-01-16       Impact factor: 6.556

4.  VASO-based calculations of CBV change: accounting for the dynamic CSF volume.

Authors:  A Scouten; R T Constable
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

5.  Direct estimation of evoked hemoglobin changes by multimodality fusion imaging.

Authors:  Theodore J Huppert; Solomon G Diamond; David A Boas
Journal:  J Biomed Opt       Date:  2008 Sep-Oct       Impact factor: 3.170

Review 6.  Current trends and challenges in MRI acquisitions to investigate brain function.

Authors:  Bradley P Sutton; Cheng Ouyang; Dimitrios C Karampinos; Gregory A Miller
Journal:  Int J Psychophysiol       Date:  2009-02-21       Impact factor: 2.997

7.  Evaluation of MRI models in the measurement of CMRO2 and its relationship with CBF.

Authors:  Ai-Ling Lin; Peter T Fox; Yihong Yang; Hanzhang Lu; Li-Hai Tan; Jia-Hong Gao
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

Review 8.  Noise concerns and post-processing procedures in cerebral blood flow (CBF) and cerebral blood volume (CBV) functional magnetic resonance imaging.

Authors:  Manus J Donahue; Meher R Juttukonda; Jennifer M Watchmaker
Journal:  Neuroimage       Date:  2016-09-11       Impact factor: 6.556

9.  Magnetization transfer enhanced vascular-space-occupancy (MT-VASO) functional MRI.

Authors:  Jun Hua; Manus J Donahue; Jason M Zhao; Ksenija Grgac; Alan J Huang; Jinyuan Zhou; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2009-04       Impact factor: 4.668

10.  Non-invasive quantification of absolute cerebral blood volume during functional activation applicable to the whole human brain.

Authors:  Pelin Aksit Ciris; Maolin Qiu; Robert Todd Constable
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.