Literature DB >> 19021411

Direct estimation of evoked hemoglobin changes by multimodality fusion imaging.

Theodore J Huppert1, Solomon G Diamond, David A Boas.   

Abstract

In the last two decades, both diffuse optical tomography (DOT) and blood oxygen level dependent (BOLD)-based functional magnetic resonance imaging (fMRI) methods have been developed as noninvasive tools for imaging evoked cerebral hemodynamic changes in studies of brain activity. Although these two technologies measure functional contrast from similar physiological sources, i.e., changes in hemoglobin levels, these two modalities are based on distinct physical and biophysical principles leading to both limitations and strengths to each method. In this work, we describe a unified linear model to combine the complimentary spatial, temporal, and spectroscopic resolutions of concurrently measured optical tomography and fMRI signals. Using numerical simulations, we demonstrate that concurrent optical and BOLD measurements can be used to create cross-calibrated estimates of absolute micromolar deoxyhemoglobin changes. We apply this new analysis tool to experimental data acquired simultaneously with both DOT and BOLD imaging during a motor task, demonstrate the ability to more robustly estimate hemoglobin changes in comparison to DOT alone, and show how this approach can provide cross-calibrated estimates of hemoglobin changes. Using this multimodal method, we estimate the calibration of the 3 tesla BOLD signal to be -0.55%+/-0.40% signal change per micromolar change of deoxyhemoglobin.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19021411      PMCID: PMC2718838          DOI: 10.1117/1.2976432

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  77 in total

1.  Estimation of respiration-induced noise fluctuations from undersampled multislice fMRI data.

Authors:  L R Frank; R B Buxton; E C Wong
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Combined MEG and EEG source imaging by minimization of mutual information.

Authors:  S Baillet; L Garnero; G Marin; J P Hugonin
Journal:  IEEE Trans Biomed Eng       Date:  1999-05       Impact factor: 4.538

3.  A qualitative test of the balloon model for BOLD-based MR signal changes at 3T.

Authors:  T Mildner; D G Norris; C Schwarzbauer; C J Wiggins
Journal:  Magn Reson Med       Date:  2001-11       Impact factor: 4.668

4.  Bayesian estimation of dynamical systems: an application to fMRI.

Authors:  K J Friston
Journal:  Neuroimage       Date:  2002-06       Impact factor: 6.556

5.  Factors affecting the accuracy of near-infrared spectroscopy concentration calculations for focal changes in oxygenation parameters.

Authors:  Gary Strangman; Maria Angela Franceschini; David A Boas
Journal:  Neuroimage       Date:  2003-04       Impact factor: 6.556

6.  Illuminating the BOLD signal: combined fMRI-fNIRS studies.

Authors:  Jens Steinbrink; Arno Villringer; Florian Kempf; Daniel Haux; Stefanie Boden; Hellmuth Obrig
Journal:  Magn Reson Imaging       Date:  2006-03-20       Impact factor: 2.546

7.  Weight-matrix structured regularization provides optimal generalized least-squares estimate in diffuse optical tomography.

Authors:  Phaneendra K Yalavarthy; Brian W Pogue; Hamid Dehghani; Keith D Paulsen
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

8.  Characterizing evoked hemodynamics with fMRI.

Authors:  K J Friston; C D Frith; R Turner; R S Frackowiak
Journal:  Neuroimage       Date:  1995-06       Impact factor: 6.556

9.  Estimation of optical pathlength through tissue from direct time of flight measurement.

Authors:  D T Delpy; M Cope; P van der Zee; S Arridge; S Wray; J Wyatt
Journal:  Phys Med Biol       Date:  1988-12       Impact factor: 3.609

10.  Methods of quantitating cerebral near infrared spectroscopy data.

Authors:  M Cope; D T Delpy; E O Reynolds; S Wray; J Wyatt; P van der Zee
Journal:  Adv Exp Med Biol       Date:  1988       Impact factor: 2.622

View more
  18 in total

1.  Quantitative evaluation of high-density diffuse optical tomography: in vivo resolution and mapping performance.

Authors:  Brian R White; Joseph P Culver
Journal:  J Biomed Opt       Date:  2010 Mar-Apr       Impact factor: 3.170

Review 2.  Molecular brain imaging in the multimodality era.

Authors:  Julie C Price
Journal:  J Cereb Blood Flow Metab       Date:  2012-03-21       Impact factor: 6.200

3.  Computer-aided interpretation approach for optical tomographic images.

Authors:  Christian D Klose; Alexander D Klose; Uwe J Netz; Alexander K Scheel; Jurgen Beuthan; Andreas H Hielscher
Journal:  J Biomed Opt       Date:  2010 Nov-Dec       Impact factor: 3.170

4.  Environmental and Genetic Influences on Neurocognitive Development: The Importance of Multiple Methodologies and Time-Dependent Intervention.

Authors:  Annette Karmiloff-Smith; B J Casey; Esha Massand; Przemyslaw Tomalski; Michael S C Thomas
Journal:  Clin Psychol Sci       Date:  2014-09-01

5.  A quantitative comparison of NIRS and fMRI across multiple cognitive tasks.

Authors:  Xu Cui; Signe Bray; Daniel M Bryant; Gary H Glover; Allan L Reiss
Journal:  Neuroimage       Date:  2010-11-01       Impact factor: 6.556

6.  Calibrating the BOLD signal during a motor task using an extended fusion model incorporating DOT, BOLD and ASL data.

Authors:  Meryem A Yücel; Theodore J Huppert; David A Boas; Louis Gagnon
Journal:  Neuroimage       Date:  2012-04-23       Impact factor: 6.556

7.  Improved recovery of the hemodynamic response in diffuse optical imaging using short optode separations and state-space modeling.

Authors:  Louis Gagnon; Katherine Perdue; Douglas N Greve; Daniel Goldenholz; Gayatri Kaskhedikar; David A Boas
Journal:  Neuroimage       Date:  2011-03-06       Impact factor: 6.556

Review 8.  HomER: a review of time-series analysis methods for near-infrared spectroscopy of the brain.

Authors:  Theodore J Huppert; Solomon G Diamond; Maria A Franceschini; David A Boas
Journal:  Appl Opt       Date:  2009-04-01       Impact factor: 1.980

9.  Brain activation during neurocognitive testing using functional near-infrared spectroscopy in patients following concussion compared to healthy controls.

Authors:  A P Kontos; T J Huppert; N H Beluk; R J Elbin; L C Henry; J French; S M Dakan; M W Collins
Journal:  Brain Imaging Behav       Date:  2014-12       Impact factor: 3.978

10.  Validation of the hypercapnic calibrated fMRI method using DOT-fMRI fusion imaging.

Authors:  Meryem A Yücel; Karleyton C Evans; Juliette Selb; Theodore J Huppert; David A Boas; Louis Gagnon
Journal:  Neuroimage       Date:  2014-09-06       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.