Literature DB >> 1765440

Cine phase-contrast magnetic resonance imaging for analysis of flow phenomena in experimental aortic dissection.

F Iwai1, H D Sostman, A J Evans, S N Nadel, L W Hedlund, C A Beam, H C Charles, C E Spritzer.   

Abstract

Using a 1.5 T magnetic resonance imaging (MRI) system, cine phase-contrast and magnitude images were obtained in three phantoms that simulated different anatomic configurations of aortic dissection. The dissection phantoms were made of compliant materials, and pulsatile flow was used in all experiments. Phantoms differed only in the location of the fenestration between the true and false lumens (I: an upstream "entry" only, II: both upstream "entry" and downstream "re-entry," and III: a downstream "entry" only). Flow jets, flap motion, and wave propagation were clearly visualized in cine MR images of each phantom, and quantitatively analyzed with reference to the stimulated cardiac cycle of the pump. Flow in the false lumen was always bidirectional. Upstream and downstream flow waves collided and dispersed within the false lumen. Flow through the false lumen was the same in phantoms I and II, and least in phantom III. The average area of the true lumen was largest in phantom III and smallest in I. Phantom I had the highest overall flow rate in the false lumen and greatest change in false lumen size during the cardiac cycle, while the downstream "entry" phantom had the lowest of both parameters. Flow phenomena in aortic dissections can be studied by cine phase-contrast MRI.

Entities:  

Mesh:

Year:  1991        PMID: 1765440     DOI: 10.1097/00004424-199112000-00007

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  3 in total

1.  Usefulness of turbo-FLASH dynamic MR imaging of dissecting aneurysms of the thoracic aorta.

Authors:  S Tomiguchi; S Morishita; R Nakashima; M Hara; Y Oyama; A Kojima; M Takahashi
Journal:  Cardiovasc Intervent Radiol       Date:  1994 Jan-Feb       Impact factor: 2.740

2.  Four-dimensional, flow-sensitive magnetic resonance imaging of blood flow patterns in thoracic aortic dissections.

Authors:  Christopher J François; Michael Markl; Mark L Schiebler; Eric Niespodzany; Benjamin R Landgraf; Christian Schlensak; Alex Frydrychowicz
Journal:  J Thorac Cardiovasc Surg       Date:  2012-07-26       Impact factor: 5.209

3.  Optimized analysis of blood flow and wall shear stress in the common carotid artery of rat model by phase-contrast MRI.

Authors:  Shin-Lei Peng; Cheng-Ting Shih; Chiun-Wei Huang; Shao-Chieh Chiu; Wu-Chung Shen
Journal:  Sci Rep       Date:  2017-07-12       Impact factor: 4.379

  3 in total