Literature DB >> 17653518

A noninvasive sizing method to choose fitted Amplatzer septal occluder by transthoracic echocardiography in patients with secundum atrial septal defects.

Kuang-Jen Chien1, Cheng-Liang Lee, Ta-Cheng Huang, Chu-Chuan Lin, Ken-Pen Weng, Shih-Hui Huang, Kai-Sheng Hsieh.   

Abstract

To simplify the conventional procedure, we developed a technique for transcatheter closure of atrial septal defects (ASDs) under transthoracic echocardiographic (TTE) sizing without balloon sizing. At present, device closure of interatrial communication has become a well-established technique to adequately treat severe left-to-right shunt associated with ASDs. During the traditional procedure, fluoroscopy with the waist of a compliant balloon is used to determine the appropriate size of the closure device and defect sizing. Choice of adequate closure device using transthoracic echocardiography (TTE) has been hitherto unreported. Between December 2002 and August 2004, 40 patients (15 males, 25 females, mean age 11.7 +/- 7.8 years) with secundum ASDs underwent transcatheter closure at our institution. In group 1, 30 patients had the procedure by balloon sizing and TTE sizing. In 10 patients (group 2), TTE sizing was used as the sole tool for selecting device size and the device size was chosen to be based on the Amplatzer septal occluder (ASO) size and TTE size ratio in group 1. The procedure was performed under continuous transesophageal echocardiographic monitoring with general anesthesia. A correlation was found between TTE and stretched balloon sizing diameter SBD (y = 1.2645x - 1.4465; R2 = 0.9861), and between TTE size and ASO size (y = 1.3412x - 1.2864; R2 = 0.9929) in group 1. In group 2, a statistical correlation between TTE and ASO (y = 1.3419x - 0.1172; R2 = 0.9934) was also found. Good linear regression between TTE size and ASO chosen size was noted in group 1 and group 2 (R2 = 0.99). In group 2, successful device implantation was accomplished in all patients whose device size was chosen to be based on the ASO and TTE ratio in group 1. Transthoracic echocardiographic sizing is a safe and ideal method to measure interatrial defect and choose the occluding device, respectively. With our experience, the sizing based on TTE is generally easier than measurement from the balloon sizing.

Entities:  

Mesh:

Year:  2007        PMID: 17653518     DOI: 10.1007/s00380-006-0959-4

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  18 in total

1.  Transcatheter Closure of Secundum Atrial Septal Defects Using the Amplatzer Septal Occluder: Clinical Experience and Technical Considerations.

Authors: 
Journal:  Curr Interv Cardiol Rep       Date:  2000-02

Review 2.  Use of intracardiac echocardiography to guide catheter closure of atrial communications.

Authors:  Peter R Koenig; Ra-id Abdulla; Qi-Ling Cao; Ziyad M Hijazi
Journal:  Echocardiography       Date:  2003-11       Impact factor: 1.724

3.  Percutaneous closure of patent foramen ovale: impact of device design on safety and efficacy.

Authors:  M Schwerzmann; S Windecker; A Wahl; H Mehta; K Nedeltchev; H Mattle; C Seiler; B Meier
Journal:  Heart       Date:  2004-02       Impact factor: 5.994

4.  Morphological study of defects of the atrial septum within the oval fossa: implications for transcatheter closure of left-to-right shunt.

Authors:  S M Ferreira; S Y Ho; R H Anderson
Journal:  Br Heart J       Date:  1992-04

5.  The role of transesophageal echocardiography in transcatheter closure of secundum atrial septal defects by the Amplatzer septal occluder.

Authors:  U Mazic; P Gavora; J Masura
Journal:  Am Heart J       Date:  2001-09       Impact factor: 4.749

6.  Transcatheter closure of secundum atrial septal defects using the new self-centering amplatzer septal occluder: initial human experience.

Authors:  J Masura; P Gavora; A Formanek; Z M Hijazi
Journal:  Cathet Cardiovasc Diagn       Date:  1997-12

7.  Intracardiac echocardiography is superior to conventional monitoring for guiding device closure of interatrial communications.

Authors:  Thomas Bartel; Thomas Konorza; Jawed Arjumand; Tiko Ebradlidze; Holger Eggebrecht; Guido Caspari; Ulrich Neudorf; Raimund Erbel
Journal:  Circulation       Date:  2003-02-18       Impact factor: 29.690

8.  Echocardiographic predictors of candidacy for successful transcatheter atrial septal defect closure.

Authors:  H M Rosenfeld; M E van der Velde; S P Sanders; S D Colan; I A Parness; J E Lock; P J Spevak
Journal:  Cathet Cardiovasc Diagn       Date:  1995-01

9.  Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect.

Authors:  Fernando Boccalandro; Edward Baptista; Andreas Muench; Catherine Carter; Richard W Smalling
Journal:  Am J Cardiol       Date:  2004-02-15       Impact factor: 2.778

10.  Transcatheter closure of patent foramen ovale in patients with cerebral ischemia.

Authors:  Martin U Braun; Dieter Fassbender; Steffen P Schoen; Markus Haass; Rainer Schraeder; Werner Scholtz; Ruth H Strasser
Journal:  J Am Coll Cardiol       Date:  2002-06-19       Impact factor: 24.094

View more
  4 in total

1.  Safety and efficacy of transcatheter closure of large patent ductus arteriosus in adults with a self-expandable occluder.

Authors:  Man-Li Yu; Xin-Miao Huang; Jia-Feng Wang; Yong-Wen Qin; Xian-Xian Zhao; Xing Zheng
Journal:  Heart Vessels       Date:  2009-11-22       Impact factor: 2.037

2.  Clinical results of percutaneous closure of large secundum atrial septal defects in children using the Amplatzer septal occluder.

Authors:  Ta Cheng Huang; Kai-Sheng Hsieh; Chu-Chun Lin; Cheng-Liang Lee
Journal:  Heart Vessels       Date:  2008-05-17       Impact factor: 2.037

3.  Transcatheter device closure of atrial septal defects guided completely by transthoracic echocardiography: A single cardiac center experience with 152 cases.

Authors:  Qiang Chen; Hua Cao; Gui Can Zhang; Liang Wan Chen; Heng Lu; Lin Li Yu
Journal:  Anatol J Cardiol       Date:  2018-12       Impact factor: 1.596

4.  A comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect.

Authors:  Alimohammad Hajizeinali; Hakimeh Sadeghian; Mehrnaz Rezvanfard; Mohammad Alidoosti; Arezoo Zoroufian; Marat A Volman
Journal:  Cardiovasc J Afr       Date:  2013-06       Impact factor: 1.167

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.