Literature DB >> 17637412

Comparison of poly-L-lactide and polylactide carbonate interference screws in an ovine anterior cruciate ligament reconstruction model.

William R Walsh1, Nick J Cotton, Paul Stephens, John E Brunelle, Andy Langdown, Jason Auld, Frank Vizesi, Warwick Bruce.   

Abstract

PURPOSE: The purpose of this study was to compare polylactide carbonate (PLC) interference screws with poly-L-lactide (PLLA) screws in an ovine anterior cruciate ligament reconstruction model.
METHODS: A PLC screw or PLLA screw was placed in the center of a 4-strand soft-tissue autograft fixating the graft within the tibial tunnel. Assessments were made at 6 and 12 weeks for fixation strength and at time points of 6, 12, 26, and 52 weeks via computed tomography and histology.
RESULTS: No adverse or inflammatory reactions were noted for either material at any time point. Mechanical fixation strength increased from 6 to 12 weeks for both the PLC and PLLA screws, with no significant differences in fixation strength being found between the 2 groups. By 26 weeks, the PLC screw was partially replaced by new bone, a process that was completed by 52 weeks. The PLLA screws were intact and surrounded by a fibrous layer at 52 weeks with no obvious resorption. New bone formation within the tendon construct located in the bone tunnel proximal to the interference screw was also noted in the PLC screw group but was not observed in the PLLA group.
CONCLUSIONS: This study has supported the hypothesis that this bioabsorbable composite has sufficient mechanical properties and strength retention to function successfully as an interference screw but also stimulates a biologic healing response, enabling replacement by bone and tunnel healing. CLINICAL RELEVANCE: This study shows both the satisfactory mechanical characteristics and osteoconductive nature of PLC used in an interference screw in an ovine anterior cruciate ligament reconstruction model.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17637412     DOI: 10.1016/j.arthro.2007.01.030

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  12 in total

1.  CALAXO osteoconductive interference screw: the value of postmarket surveillance.

Authors:  Charles L Cox; Kelly C Homlar; James L Carey; Kurt P Spindler
Journal:  J Surg Orthop Adv       Date:  2010

2.  Inflammatory response with osteolysis related to a bioabsorbable anchor in the finger: a case report.

Authors:  Gregory J Galano; Kevin N Jiang; Robert J Strauch; Melvin P Rosenwasser; Peter Tang
Journal:  Hand (N Y)       Date:  2009-11-07

3.  [Biodegradable screw versus a press-fit bone plug fixation for ACL reconstruction: a prospective randomized study].

Authors:  B Geiges; C von Falck; K Knobloch; C Haasper; R Meller; C Krettek; S Hankemeier; J Brand; M Jagodzinski
Journal:  Unfallchirurg       Date:  2013-02       Impact factor: 1.000

Review 4.  Migration of "bioabsorbable" screws in ACL repair. How much do we know? A systematic review.

Authors:  Hélder Pereira; Hélder M D Pereira; Vítor M Correlo; Joana Silva-Correia; Joaquim M Oliveira; Rui L Reis; Rui L Reis Ceng; João Espregueira-Mendes
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-03       Impact factor: 4.342

5.  Do newer-generation bioabsorbable screws become incorporated into bone at two years after ACL reconstruction with patellar tendon graft?: A cohort study.

Authors:  Charles L Cox; Kurt P Spindler; James P Leonard; Brent J Morris; Warren R Dunn; Emily K Reinke
Journal:  J Bone Joint Surg Am       Date:  2014-02-05       Impact factor: 5.284

6.  Influence of hydroxyapatite-coated and growth factor-releasing interference screws on tendon-bone healing in an ovine model.

Authors:  Yan Lu; Mark D Markel; Brett Nemke; J Sam Lee; Ben K Graf; William L Murphy
Journal:  Arthroscopy       Date:  2009-11-06       Impact factor: 4.772

7.  Tibial tunnel widening after bioresorbable poly-lactide calcium carbonate interference screw usage in ACL reconstruction.

Authors:  Casper Foldager; Bent W Jakobsen; Bent Lund; Svend Erik Christiansen; Lotte Kashi; Lone R Mikkelsen; Martin Lind
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-16       Impact factor: 4.342

8.  The unpredictable material properties of bioabsorbable PLC interference screws and their adverse effects in ACL reconstruction surgery.

Authors:  Sujith Konan; Fares Sami Haddad
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-12-16       Impact factor: 4.342

9.  Poly(acrylic acid)-regulated Synthesis of Rod-Like Calcium Carbonate Nanoparticles for Inducing the Osteogenic Differentiation of MC3T3-E1 Cells.

Authors:  Wei Yang; Chenxue Yao; Zhengyang Cui; Dandan Luo; In-Seop Lee; Juming Yao; Cen Chen; Xiangdong Kong
Journal:  Int J Mol Sci       Date:  2016-05-06       Impact factor: 5.923

Review 10.  Femoral fracture following knee ligament reconstruction surgery due to an unpredictable complication of bioabsorbable screw fixation: a case report and review of literature.

Authors:  Sujith Konan; Fares Sami Haddad
Journal:  J Orthop Traumatol       Date:  2009-12-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.