An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery.

R B P de Wilde1, J J Schreuder, P C M van den Berg, J R C Jansen.   

Abstract

The bias, precision and tracking ability of five different pulse contour methods were evaluated by simultaneous comparison of cardiac output values from the conventional thermodilution technique (COtd). The five different pulse contour methods included in this study were: Wesseling's method (cZ); the Modelflow method; the LiDCO system; the PiCCO system and a recently developed Hemac method. We studied 24 cardiac surgery patients undergoing uncomplicated coronary artery bypass grafting. In each patient, the first series of COtd was used to calibrate the five pulse contour methods. In all, 199 series of measurements were accepted by all methods and included in the study. COtd ranged from 2.14 to 7.55 l.min(-1), with a mean of 4.81 l.min(-1). Bland-Altman analysis showed the following bias and limits of agreement: cZ, 0.23 and - 0.80 to 1.26 l.min(-1); Modelflow, 0.00 and - 0.74 to 0.74 l.min(-1); LiDCO, - 0.17 and - 1.55 to 1.20 l.min(-1); PiCCO, 0.14 and - 1.60 to 1.89 l.min(-1); and Hemac, 0.06 and - 0.81 to 0.93 l.min(-1). Changes in cardiac output larger than 0.5 l.min(-1) (10%) were correctly followed by the Modelflow and the Hemac method in 96% of cases. In this group of subjects, without congestive heart failure, with normal heart rhythm and reasonable peripheral circulation, the best results in absolute values as well as in tracking changes in cardiac output were measured using the Modelflow and Hemac pulse contour methods, based on non-linear three-element Windkessel models.

Entities:  

Mesh:

Year:  2007        PMID: 17635422     DOI: 10.1111/j.1365-2044.2007.05135.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  36 in total

Review 1.  The arterial Windkessel.

Authors:  Nico Westerhof; Jan-Willem Lankhaar; Berend E Westerhof
Journal:  Med Biol Eng Comput       Date:  2008-06-10       Impact factor: 2.602

2.  Haemodynamic adaptation during sudden gravity transitions.

Authors:  Jiexin Liu; Bart Verheyden; Frank Beckers; Andre E Aubert
Journal:  Eur J Appl Physiol       Date:  2011-04-11       Impact factor: 3.078

Review 3.  Methods in pharmacology: measurement of cardiac output.

Authors:  Bart F Geerts; Leon P Aarts; Jos R Jansen
Journal:  Br J Clin Pharmacol       Date:  2011-03       Impact factor: 4.335

4.  Tracking changes in cardiac output: methodological considerations for the validation of monitoring devices.

Authors:  Pierre Squara; Maurizio Cecconi; Andrew Rhodes; Mervyn Singer; Jean-Daniel Chiche
Journal:  Intensive Care Med       Date:  2009-07-11       Impact factor: 17.440

5.  Cardiac output measurement by arterial pressure waveform analysis during optimization of biventricular pacing after cardiac surgery.

Authors:  Justin H Booth; T Alexander Quinn; Marc E Richmond; Santos E Cabreriza; Alan D Weinberg; Taylor Johnston; Henry M Spotnitz
Journal:  ASAIO J       Date:  2009 Nov-Dec       Impact factor: 2.872

6.  Importance of re-calibration time on pulse contour analysis agreement with thermodilution measurements of cardiac output: a retrospective analysis of intensive care unit patients.

Authors:  Christopher G Scully; Shanti Gomatam; Shawn Forrest; David G Strauss
Journal:  J Clin Monit Comput       Date:  2015-08-19       Impact factor: 2.502

Review 7.  Choosing patient-tailored hemodynamic monitoring.

Authors:  Cornelis Slagt; Rose-Marieke B G E Breukers; A B Johan Groeneveld
Journal:  Crit Care       Date:  2010-03-09       Impact factor: 9.097

8.  Recent advance in patient monitoring.

Authors:  Tomoki Nishiyama
Journal:  Korean J Anesthesiol       Date:  2010-09-20

9.  Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients.

Authors:  John F Stover; Reto Stocker; Renato Lenherr; Thomas A Neff; Silvia R Cottini; Bernhard Zoller; Markus Béchir
Journal:  BMC Anesthesiol       Date:  2009-10-12       Impact factor: 2.217

10.  Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring.

Authors:  Sophie Marqué; Alain Cariou; Jean-Daniel Chiche; Pierre Squara
Journal:  Crit Care       Date:  2009-05-19       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.