Literature DB >> 17634881

Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT.

Yumi Yanaga1, Kazuo Awai, Yoshiharu Nakayama, Takeshi Nakaura, Yoshitaka Tamura, Yoshinori Funama, Masahito Aoyama, Naoki Asada, Yasuyuki Yamashita.   

Abstract

PURPOSE: The aim of this study was to investigate the optimal dose and injection duration of contrast material (CM) for depicting hypervascular hepatocellular carcinomas (HCCs) during the hepatic arterial phase with multidetector row computed tomography (CT).
MATERIALS AND METHODS: The study population consisted of 71 patients with hypervascular HCCs. After unenhanced scans, the first (early arterial phase, or EAP), second (late arterial phase, or LAP), and third (equilibrium phase) scanning was started at 30, 43, and 180 s after injection of contrast material (CM). During a 33-s period, patients with a body weight < or =50 kg received 100 ml of non-ionic CM with an iodine concentration of 300 mg I/ml; patients whose body weight was >50 kg received 100 ml of CM with an iodine concentration of 370 mg I/ml. First, we measured enhancement in the abdominal aorta and tumor-to-liver contrast (TLC) during the EAP and LAP. Next, to investigate the relation between aortic enhancement and TLC during the LAP, two radiologists visually assessed the conspicuity of hypervascular HCCs during the LAP using a 3-point scale: grade 1, poor; grade 2, fair; grade 3, excellent. Finally, to examine the effect of the CM dose and injection duration on aortic enhancement during the EAP, we simulated aortic enhancement curves using test bolus data obtained for 10 HCC patients and the method of Fleischmann and Hittmair.
RESULTS: A relatively strong correlation was observed between aortic enhancement during the EAP and TLC during the LAP (correlation coefficient r = 0.75, P < 0.001). The 95% confidence intervals for the population mean for aortic enhancement during EAP in patients with tumor conspicuity grades of 1, 2, and 3 were 188.5, 222.4; 228.8, 259.3; and 280.2, 322.5 HU (Hounsfield Unit), respectively. Thus, we considered the lower limit of the aortic enhancement value for excellent depiction of HCCs during EAP to be 280 HU. To achieve an aortic enhancement value of >280 HU for aortic enhancement simulations during EAP, the injection duration should be <25 s for patients receiving a CM dose of 1.7 ml/kg with 300 mg I/ml iodine and <30 s for those receiving 2.0 ml/kg.
CONCLUSIONS: For excellent depiction of hypervascular HCCs during the hepatic arterial phase, the injection duration should be <25 s in patients receiving a CM dose of 1.7 ml/kg with 300 mg I/ml iodine and <30 s for patients receiving 2.0 ml/kg.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17634881     DOI: 10.1007/s11604-007-0138-2

Source DB:  PubMed          Journal:  Radiat Med        ISSN: 0288-2043


  38 in total

1.  Hepatic enhancement in multiphasic contrast-enhanced MDCT: comparison of high- and low-iodine-concentration contrast medium in same patients with chronic liver disease.

Authors:  Akihiro Furuta; Katsuyoshi Ito; Takeshi Fujita; Shinji Koike; Ayame Shimizu; Naofumi Matsunaga
Journal:  AJR Am J Roentgenol       Date:  2004-07       Impact factor: 3.959

2.  Hepatic lesion characterization in cirrhosis: significance of arterial hypervascularity on dual-phase helical CT.

Authors:  H M Lee; D S Lu; R M Krasny; R Busuttil; B Kadell; J Lucas
Journal:  AJR Am J Roentgenol       Date:  1997-07       Impact factor: 3.959

3.  Benign and malignant nodules in cirrhotic livers: distinction based on blood supply.

Authors:  O Matsui; M Kadoya; T Kameyama; J Yoshikawa; T Takashima; Y Nakanuma; M Unoura; K Kobayashi; R Izumi; M Ida
Journal:  Radiology       Date:  1991-02       Impact factor: 11.105

4.  Dual-phase helical CT of the liver: value of an early-phase acquisition in the differential diagnosis of noncystic focal lesions.

Authors:  L Van Hoe; A L Baert; S Gryspeerdt; G Vandenbosh; F Nevens; W Van Steenbergen; G Marchal
Journal:  AJR Am J Roentgenol       Date:  1997-05       Impact factor: 3.959

5.  Multidetector CT of the liver and hepatic neoplasms: effect of multiphasic imaging on tumor conspicuity and vascular enhancement.

Authors:  Isaac R Francis; Richard H Cohan; Nancy J McNulty; Joel F Platt; Melvyn Korobkin; Achamyeleh Gebremariam; Kartik I Ragupathi
Journal:  AJR Am J Roentgenol       Date:  2003-05       Impact factor: 3.959

6.  Abdominal helical CT: evaluation of optimal doses of intravenous contrast material--a prospective randomized study.

Authors:  Y Yamashita; Y Komohara; M Takahashi; M Uchida; N Hayabuchi; T Shimizu; I Narabayashi
Journal:  Radiology       Date:  2000-09       Impact factor: 11.105

7.  Diagnosis of small hepatocellular carcinoma by computed tomography: correlation of CT findings and histopathology.

Authors:  S Tsunetomi; M Ohto; Y Iino; T Shinagawa; K Kimura; M Morita; H Saisho; Y Tsuchiya; N Hirooka; K Okuda
Journal:  J Gastroenterol Hepatol       Date:  1989 Sep-Oct       Impact factor: 4.029

8.  Dual-phase helical CT of the liver: value of arterial phase scans in the detection of small (< or = 1.5 cm) malignant hepatic neoplasms.

Authors:  M D Hollett; R B Jeffrey; M Nino-Murcia; M J Jorgensen; D P Harris
Journal:  AJR Am J Roentgenol       Date:  1995-04       Impact factor: 3.959

9.  Hepatocellular carcinoma: detection with triple-phase multi-detector row helical CT in patients with chronic hepatitis.

Authors:  Andrea Laghi; Riccardo Iannaccone; Plinio Rossi; Iacopo Carbone; Riccardo Ferrari; Filippo Mangiapane; Italo Nofroni; Roberto Passariello
Journal:  Radiology       Date:  2003-02       Impact factor: 11.105

10.  Hypervascular hepatocellular carcinoma: can double arterial phase imaging with multidetector CT improve tumor depiction in the cirrhotic liver?

Authors:  Tomoaki Ichikawa; Takatoshi Kitamura; Hiroto Nakajima; Hironobu Sou; Tatsuaki Tsukamoto; Satoshi Ikenaga; Tsutomu Araki
Journal:  AJR Am J Roentgenol       Date:  2002-09       Impact factor: 3.959

View more
  7 in total

1.  Totally implantable venous power ports of the forearm and the chest: initial clinical experience with port devices approved for high-pressure injections.

Authors:  J P Goltz; C Noack; B Petritsch; J Kirchner; D Hahn; R Kickuth
Journal:  Br J Radiol       Date:  2012-06-06       Impact factor: 3.039

2.  Subtracted 3D CT angiography for the evaluation of intracranial aneurysms in 256-slice multidetector CT: usefulness of the 80-kVp plus compact contrast medium bolus protocol.

Authors:  Masafumi Kidoh; Takeshi Nakaura; Takaaki Ogata; Hiroki Takashima; Makoto Yoshikawa; Shouzaburou Uemura; Kazunori Harada; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2013-06-08       Impact factor: 5.315

3.  Contrast enhancement in abdominal computed tomography: influence of photon energy of different scanners.

Authors:  Narumi Taguchi; Seitaro Oda; Takeshi Nakaura; Daisuke Utsunomiya; Yoshinori Funama; Masanori Imuta; Hideaki Yuki; Yasunori Nagayama; Masafumi Kidoh; Kenichiro Hirata; Yuji Iyama; Tomohiro Namimoto; Noriyuki Kai; Masahiro Hatemura; Yasuyuki Yamashita
Journal:  Br J Radiol       Date:  2017-11-06       Impact factor: 3.039

4.  Minimizing individual variations in arterial enhancement on coronary CT angiographs using "contrast enhancement optimizer": a prospective randomized single-center study.

Authors:  Yoriaki Matsumoto; Toru Higaki; Takanori Masuda; Tomoyasu Sato; Yuko Nakamura; Fuminari Tatsugami; Kazuo Awai
Journal:  Eur Radiol       Date:  2018-11-12       Impact factor: 5.315

5.  Contrast enhancement on 100- and 120 kVp hepatic CT scans at thin adults in a retrospective cohort study: Bayesian inference of the optimal enhancement probability.

Authors:  Takanori Masuda; Takeshi Nakaura; Yoshinori Funama; Tomoyasu Sato; Toru Higaki; Yoriaki Matsumoto; Yukari Yamashita; Naoyuki Imada; Masao Kiguchi; Yasutaka Baba; Yasuyuki Yamashita; Kazuo Awai
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

6.  The efficacy of contrast protocol in hepatic dynamic computed tomography: multicenter prospective study in community hospitals.

Authors:  Masahiro Okada; Hiroshi Kondo; Hironobu Sou; Takamichi Murakami; Masayuki Kanematsu; Tomoaki Ichikawa; Shushi Yoshikawa; Kazuhito Shiosakai; Akiko Hayakawa; Kazuo Awai; Kengo Yoshimitsu; Yasuyuki Yamashita
Journal:  Springerplus       Date:  2013-07-31

7.  Comparison of enhancement and image quality: different iodine concentrations for liver on 128-slice multidetector computed tomography in the same chronic liver disease patients.

Authors:  Byoung Goo Jo; Yun Gyu Song; Sang Goon Shim; Young Wook Kim
Journal:  Korean J Intern Med       Date:  2015-12-23       Impact factor: 2.884

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.