Literature DB >> 17634649

A two isocenter IMRT technique with a controlled junction dose for long volume targets.

G G Zeng1, R K Heaton, C N Catton, P W Chung, B O'Sullivan, M Lau, A Parent, D A Jaffray.   

Abstract

Most IMRT techniques have been designed to treat targets smaller than the field size of conventional linac accelerators. In order to overcome the field size restrictions in applying IMRT, we developed a two isocenter IMRT technique to treat long volume targets. The technique exploits an extended dose gradient throughout a junction region of 4-6 cm to minimize the impact of field match errors on a junction dose and manipulates the inverse planning and IMRT segments to fill in the dose gradient and achieve dose uniformity. Techniques for abutting both conventional fields with IMRT ('Static + IMRT') and IMRT fields ('IMRT + IMRT') using two separate isocenters have been developed. Five long volume sarcoma cases have been planned in Pinnacle (Philips, Madison, USA) using Elekta Synergy and Varian 2100EX linacs; two of the cases were clinically treated with this technique. Advantages were demonstrated with well-controlled junction target uniformity and tolerance to setup uncertainties. The junction target dose heterogeneity was controlled at a level of +/-5%; for 3 mm setup errors at the field edges, the junction target dose changed less than 5% and the dose sparing to organs at risk (OARs) was maintained. Film measurements confirmed the treatment planning results.

Entities:  

Mesh:

Year:  2007        PMID: 17634649     DOI: 10.1088/0031-9155/52/15/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Many-isocenter optimization for robotic radiotherapy.

Authors:  Qihui Lyu; Ryan Neph; Victoria Y Yu; Dan Ruan; Salime Boucher; Ke Sheng
Journal:  Phys Med Biol       Date:  2020-02-10       Impact factor: 3.609

2.  MLC-based penumbra softener of EDW borders to reduce junction inhomogeneities.

Authors:  Stanislaw Szpala; Kirpal Kohli
Journal:  J Appl Clin Med Phys       Date:  2017-04-19       Impact factor: 2.102

Review 3.  Total marrow irradiation for hematopoietic malignancies using volumetric modulated arc therapy: A review of treatment planning studies.

Authors:  Pietro Mancosu; Luca Cozzi; Ludvig Paul Muren
Journal:  Phys Imaging Radiat Oncol       Date:  2019-08-29

4.  Early clinical experience with varian halcyon V2 linear accelerator: Dual-isocenter IMRT planning and delivery with portal dosimetry for gynecological cancer treatments.

Authors:  Hayeon Kim; M Saiful Huq; Ron Lalonde; Christopher J Houser; Sushil Beriwal; Dwight E Heron
Journal:  J Appl Clin Med Phys       Date:  2019-10-29       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.