Literature DB >> 17629999

Quantification of pain in laparoscopic transabdominal preperitoneal (TAPP) inguinal hernioplasty identifies marked differences between prosthesis fixation systems.

Stefano Olmi1, Alberto Scaini, Luigi Erba, Marcello Guaglio, Enrico Croce.   

Abstract

BACKGROUND: Various systems exist for prosthesis fixation in hernia repair. These techniques vary in terms of postoperative complications and pain. This study compares prosthesis fixation techniques employed in laparoscopic transabdominal preperitoneal (TAPP) hernioplasty using a visual analog scale (VAS) to quantify postoperative pain.
METHODS: Patients (n = 600) underwent TAPP inguinal hernia repair in a randomized prospective study. Prostheses were fixed with Protak (Tyco, Norwalk, Conn), (Group A; n = 150), EndoANCHOR (Ethicon Endo-Surgery, Inc., Cincinnati, Ohio) (Group B; n = 150), EMS (Ethicon Endo-Surgery, Inc.) (Group C; n = 150), or Tissucol (Baxter Healthcare, Milan, Italy) (Group D; n = 150). Patients were interviewed up to 1 month post-intervention. Post-operative pain was evaluated on a 0- to 10-point VAS (0 = no pain, 10 = maximum pain). Morbidity, length of stay, return to work and recurrence were also assessed.
RESULTS: Overall, 803 hernias were treated: 397 patients (66.2%) had unilateral hernias and 203 (33.8%) had bilateral hernias. In total, 96 (12%) hernias were recurrences and 707 (88%) were primary. Postoperative pain ranged from VAS1 to VAS2 (mild pain) between 12 hours and 72 hours with Tissucol (Group D), and it was higher in Groups A-C: Maxima ranged from VAS4 (moderate pain) with EMS to VAS7 (severe pain) with Protak at 48-hour follow-up. Significant differences in length of stay occurred, no recurrence or conversion rates were observed among groups, and morbidity was generally lower with Tissucol. Patients in Group D (Tissucol) also returned to work sooner than did Groups A-C (Protak, EndoANCHOR, and EMS).
CONCLUSIONS: We found differences in postoperative pain among different laparoscopic TAPP prosthesis fixation methods. The use of the biocompatible fibrin sealant Tissucol seems to reduce significantly postoperative pain, complications, and resumption to work times compared with other systems.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17629999     DOI: 10.1016/j.surg.2007.02.013

Source DB:  PubMed          Journal:  Surgery        ISSN: 0039-6060            Impact factor:   3.982


  37 in total

1.  Comparison of peritoneal closure versus non-closure in laparoscopic trans-abdominal preperitoneal inguinal hernia repair with coated mesh.

Authors:  Erica D Kane; Marc Leduc; Kathryn Schlosser; Nicole Parentela; Donna Wilson; John R Romanelli
Journal:  Surg Endosc       Date:  2017-08-04       Impact factor: 4.584

2.  Groin hernia repair in young males: mesh or sutured repair?

Authors:  T Bisgaard; M Bay-Nielsen; H Kehlet
Journal:  Hernia       Date:  2010-05-09       Impact factor: 4.739

3.  Fixation of mesh to the peritoneum using a fibrin glue: investigations with a biomechanical model and an experimental laparoscopic porcine model.

Authors:  C Schug-Pass; H Lippert; F Köckerling
Journal:  Surg Endosc       Date:  2009-05-23       Impact factor: 4.584

Review 4.  Use of fibrin sealant (Tisseel/Tissucol) in hernia repair: a systematic review.

Authors:  René H Fortelny; Alexander H Petter-Puchner; Karl S Glaser; Heinz Redl
Journal:  Surg Endosc       Date:  2012-01-26       Impact factor: 4.584

5.  A "self adhering" prosthesis for hernia repair: experimental study.

Authors:  G Champault; C Polliand; F Dufour; M Ziol; L Behr
Journal:  Hernia       Date:  2008-08-23       Impact factor: 4.739

6.  EAES Consensus Development Conference on endoscopic repair of groin hernias.

Authors:  M M Poelman; B van den Heuvel; J D Deelder; G S A Abis; N Beudeker; R R Bittner; G Campanelli; D van Dam; B J Dwars; H H Eker; A Fingerhut; I Khatkov; F Koeckerling; J F Kukleta; M Miserez; A Montgomery; R M Munoz Brands; S Morales Conde; F E Muysoms; M Soltes; W Tromp; Y Yavuz; H J Bonjer
Journal:  Surg Endosc       Date:  2013-05-25       Impact factor: 4.584

Review 7.  Convalescence after laparoscopic inguinal hernia repair: a qualitative systematic review.

Authors:  Mette Astrup Tolver; Jacob Rosenberg; Thue Bisgaard
Journal:  Surg Endosc       Date:  2016-04-08       Impact factor: 4.584

Review 8.  Causes of recurrence in laparoscopic inguinal hernia repair.

Authors:  Manjunath Siddaiah-Subramanya; Darius Ashrafi; Breda Memon; Muhammed Ashraf Memon
Journal:  Hernia       Date:  2018-08-25       Impact factor: 4.739

9.  Mesh fixation with fibrin glue (Tissucol/Tisseel) in hernia repair dependent on the mesh structure--is there an optimum fibrin-mesh combination?--investigations on a biomechanical model.

Authors:  Christine Schug-Pass; Hans Lippert; Ferdinand Köckerling
Journal:  Langenbecks Arch Surg       Date:  2009-01-31       Impact factor: 3.445

10.  Pain, quality of life and recovery after laparoscopic ventral hernia repair.

Authors:  J R Eriksen; P Poornoroozy; L N Jørgensen; B Jacobsen; H U Friis-Andersen; J Rosenberg
Journal:  Hernia       Date:  2008-08-01       Impact factor: 4.739

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.