Literature DB >> 17628416

Analysis of segmental and global function of the fetal heart using novel automatic functional imaging.

Asaf Ta-Shma1, Zeev Perles, Sagui Gavri, Julius Golender, Shulamit Tarshansky, Chava Shlichter, Hadassah Bar Tov, Azaria J J T Rein.   

Abstract

BACKGROUND: Functional assessment of the fetal heart has always been a challenge. Automatic functional imaging (AFI), a novel non-Doppler methodology based on 2-dimensional acoustic markers tracking, measures myocardial deformation regardless of angle of interrogation. Thus, we studied the validity of AFI in segmental and global assessment of myocardial function in the fetus.
METHODS: AFI-based myocardial deformation parameters including segmental tissue velocity, strain, and strain rate as well as biventricular global strain and strain rate were measured from raw scan-line data obtained from 28 normal fetuses (20-38, median 28 weeks of gestation). Interobserver and intraobserver variability was analyzed. AFI data were compared with analogous Doppler-derived tissue velocity imaging parameters measured in the same 28 fetuses.
RESULTS: AFI was feasible in 94% of the fetuses studied with high reproducibility. AFI-based tissue velocity (3.9 +/- 1 cm/s) was comparable with tissue velocity imaging-based velocity (4 +/- 1.6 cm/s) in the right ventricle and in the left ventricle (AFI velocity 3.3 +/- 0.6 vs tissue velocity imaging 3.1 +/- 0.9 cm/s). Strain rate obtained by these two methods was also similar. Biventricular global strain and strain rate measured 16 +/- 4% and 1.6 +/- .5 seconds(-1), respectively. Tissue velocity increased whereas segmental strain rate decreased throughout gestation. Strain remained unchanged. Global strain rate significantly decreased with gestational age (r = -0.7).
CONCLUSION: AFI, a novel non-Doppler methodology, allows fast and accurate quantification of segmental and global myocardial function in the fetus. AFI-based tissue velocity increases with gestational age whereas segmental and the new parameter global strain rate decrease throughout gestation.

Entities:  

Mesh:

Year:  2007        PMID: 17628416     DOI: 10.1016/j.echo.2007.05.007

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  10 in total

1.  Intracardiac echogenic foci have no hemodynamic significance in the fetus.

Authors:  Zeev Perles; Amiram Nir; Sagui Gavri; Julius Golender; Azaria J J T Rein
Journal:  Pediatr Cardiol       Date:  2009-08-29       Impact factor: 1.655

2.  Evaluation of congenital left ventricular aneurysm in the fetus by velocity vector imaging.

Authors:  Shintaro Makino; Toshitaka Tanaka; Moe Makita; Shigeru Itoh; Satoru Takeda
Journal:  J Med Ultrason (2001)       Date:  2009-07-31       Impact factor: 1.314

3.  Feasibility and Reproducibility of Two-Dimensional Wall Motion Tracking (WMT) in Fetal Echocardiography.

Authors:  Christian Enzensberger; Friederike Achterberg; Jan Degenhardt; Aline Wolter; Oliver Graupner; Johannes Herrmann; Roland Axt-Fliedner
Journal:  Ultrasound Int Open       Date:  2017-02

4.  Circumferential and longitudinal ventricular strain in the normal human fetus.

Authors:  Tetsuko Ishii; Doff B McElhinney; David M Harrild; Edward N Marcus; David J Sahn; Uyen Truong; Wayne Tworetzky
Journal:  J Am Soc Echocardiogr       Date:  2011-10-26       Impact factor: 5.251

5.  Fetal regional myocardial strain rate in the membranous ventricular septum: changes with gestational age and the left ventricular mass and predictive value for a complete membranous ventricular septum (without defect).

Authors:  Li-Juan Zhang; Ke-Qi Chen; Yun-Yan Shi; Xiao-Zhi Zheng
Journal:  Int J Cardiovasc Imaging       Date:  2018-04-17       Impact factor: 2.357

6.  Quantitative Assessment of Cardiac Function in Fetuses of Women with Maternal Gestational Thyroid Dysfunction Using VVI Echocardiography.

Authors:  Meixin Liu; Jing Yu; Xiuxiu Fu; Wei Wan
Journal:  Med Sci Monit       Date:  2015-10-02

Review 7.  4D imaging of fetal right ventricle-feasibility study and a review of the literature.

Authors:  M Pasieczna; J Duliban; A Grzyb; J Szymkiewicz-Dangel
Journal:  Int J Cardiovasc Imaging       Date:  2021-09-20       Impact factor: 2.357

8.  Feasibility of 4D-Spatio Temporal Image Correlation (STIC) in the Comprehensive Assessment of the Fetal Heart Using FetalHQ®.

Authors:  Laura Nogué; Olga Gómez; Nora Izquierdo; Cristina Mula; Narcís Masoller; Josep M Martínez; Eduard Gratacós; Greggory Devore; Fàtima Crispi; Mar Bennasar
Journal:  J Clin Med       Date:  2022-03-04       Impact factor: 4.241

9.  Fetal myocardial deformation measured with two-dimensional speckle-tracking echocardiography: longitudinal prospective cohort study of 124 healthy fetuses.

Authors:  N H M van Oostrum; C M de Vet; S B Clur; D A A van der Woude; E R van den Heuvel; S G Oei; J O E H van Laar
Journal:  Ultrasound Obstet Gynecol       Date:  2022-04-06       Impact factor: 8.678

10.  Normal fetal cardiac deformation values in pregnancy; a prospective cohort study protocol.

Authors:  Noortje H M van Oostrum; S Guid Oei; Judith O E H van Laar
Journal:  BMC Pregnancy Childbirth       Date:  2019-12-27       Impact factor: 3.007

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.