Literature DB >> 17625946

Non-contact cardiac monitoring from carotid artery using optical vibrocardiography.

Lorenzo Scalise1, Umberto Morbiducci.   

Abstract

The aim of the present work is to establish a protocol for monitoring the cardiac activity measuring the skin surface vibrations of the main neck vessels, caused by vascular wall motion in carotid artery. The method is based on the optical recording of the movements of the neck by means of laser Doppler interferometry. The ECG signal and the velocity of vibration of the skin in correspondence of the carotid artery (named optical vibrocardiography: VCG) have been simultaneously recorded on five healthy subjects. Standard heart rate variability tests have been carried out. The capability of VCG signals to be used as a surrogate of the ECG in assessing both cardiac rate and heart rate variability (HRV) has been tested using time and spectral descriptors, and specific statistical analysis. Mean differences have been found lower than 3.13%. Optical vibrocardiography might be a simple approach to the clinical practice of cardiovascular screening, in particular in harsh environment, such as MR clinical practice, where ECG recordings are corrupted by artefacts and ECG cables might represent an hazard for the patients.

Entities:  

Mesh:

Year:  2007        PMID: 17625946     DOI: 10.1016/j.medengphy.2007.05.008

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  9 in total

1.  Laser doppler myography (LDMi): A novel non-contact measurement method for the muscle activity.

Authors:  L Scalise; S Casaccia; P Marchionni; I Ercoli; Ep Tomasini
Journal:  Laser Ther       Date:  2013-12-30

2.  Novel Applications of Laser Doppler Vibration Measurements to Medical Imaging.

Authors:  Habib Tabatabai; David E Oliver; John W Rohrbaugh; Christopher Papadopoulos
Journal:  Sens Imaging       Date:  2013-08-13

3.  Time-Frequency Distribution of Seismocardiographic Signals: A Comparative Study.

Authors:  Amirtaha Taebi; Hansen A Mansy
Journal:  Bioengineering (Basel)       Date:  2017-04-07

4.  Effect of Noise on Time-frequency Analysis of Vibrocardiographic Signals.

Authors:  A Taebi; H A Mansy
Journal:  J Bioeng Biomed Sci       Date:  2016-09-15

Review 5.  Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review.

Authors:  Luwei Nie; Daniel Berckmans; Chaoyuan Wang; Baoming Li
Journal:  Sensors (Basel)       Date:  2020-04-17       Impact factor: 3.576

6.  Using smart speakers to contactlessly monitor heart rhythms.

Authors:  Anran Wang; Dan Nguyen; Arun R Sridhar; Shyamnath Gollakota
Journal:  Commun Biol       Date:  2021-03-09

7.  Template Matching and Matrix Profile for Signal Quality Assessment of Carotid and Femoral Laser Doppler Vibrometer Signals.

Authors:  Silvia Seoni; Simeon Beeckman; Yanlu Li; Soren Aasmul; Umberto Morbiducci; Roel Baets; Pierre Boutouyrie; Filippo Molinari; Nilesh Madhu; Patrick Segers
Journal:  Front Physiol       Date:  2022-01-11       Impact factor: 4.566

Review 8.  Novel Methods for Pulse Wave Velocity Measurement.

Authors:  Tânia Pereira; Carlos Correia; João Cardoso
Journal:  J Med Biol Eng       Date:  2015-10-14       Impact factor: 1.553

9.  Current Developments on Optical Feedback Interferometry as an All-Optical Sensor for Biomedical Applications.

Authors:  Julien Perchoux; Adam Quotb; Reza Atashkhooei; Francisco J Azcona; Evelio E Ramírez-Miquet; Olivier Bernal; Ajit Jha; Antonio Luna-Arriaga; Carlos Yanez; Jesus Caum; Thierry Bosch; Santiago Royo
Journal:  Sensors (Basel)       Date:  2016-05-13       Impact factor: 3.576

  9 in total