An experimental method for measuring force on the spinal facet joint: description and application of the method.

G R Buttermann1, R D Kahmann, J L Lewis, D S Bradford.   

Abstract

A technique is described for measuring load magnitude and resultant load contact location in the facet joint in response to applied loads and moments, and the technique applied to the canine lumbar spine motion segment. Due to the cantilever beam geometry of the cranial articular process, facet joint loads result in surface strains on the lateral aspect of the cranial articular process. Strains were quantified by four strain gages cemented to the bony surface of the process. Strain measured at any one gage depended on the loading site on the articular surface of the caudal facet and on the magnitude of the facet load. Determination of facet loads during in vitro motion segment testing required calibration of the strains to known loads of various magnitudes applied to multiple sites on the caudal facet. The technique is described in detail, including placement of the strain gages. There is good repeatability of strains to applied facet loads and the strains appear independent of load distribution area. Error in the technique depends on the location of the applied facet loads, but is only significant in nonphysiologic locations. The technique was validated by two independent methods in axial torsion. Application of the technique to five in vitro canine L2-3 motion segments testing resulted in facet loads (in newtons, N) of 74+ / -23 N (mean + / -STD) in 2 newton-meter, Nm, extension, to unloaded in flexion. Lateral bending resulted in loads in the right facet of 40+ / -32 N for 1 Nm right lateral bending and 54+ / -29 N for 1 Nm left lateral bending. 4 Nm Torsion with and without 100 N axial compression resulted in facet loads of 92+ / -27 N and 69+ / -19 N, respectively. The technique is applicable to dynamic and in vivo studies.

Entities:  

Mesh:

Year:  1991        PMID: 1762433     DOI: 10.1115/1.2895415

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  5 in total

1.  Finite element analysis and cadaveric cinematic analysis of fixation options for anteriorly implanted trabecular metal interbody cages.

Authors:  Pedro Berjano; Juan Francisco Blanco; Diego Rendon; Jorge Hugo Villafañe; David Pescador; Carlos Manuel Atienza
Journal:  Eur Spine J       Date:  2015-10-09       Impact factor: 3.134

2.  The instant axis of rotation influences facet forces at L5/S1 during flexion/extension and lateral bending.

Authors:  Marc-Antoine Rousseau; David S Bradford; Tamer M Hadi; Kirk L Pedersen; Jeffery C Lotz
Journal:  Eur Spine J       Date:  2005-09-20       Impact factor: 3.134

Review 3.  Spinal facet joint biomechanics and mechanotransduction in normal, injury and degenerative conditions.

Authors:  Nicolas V Jaumard; William C Welch; Beth A Winkelstein
Journal:  J Biomech Eng       Date:  2011-07       Impact factor: 2.097

4.  Biomechanical response of lumbar facet joints under follower preload: a finite element study.

Authors:  Cheng-Fei Du; Nan Yang; Jun-Chao Guo; Yun-Peng Huang; Chunqiu Zhang
Journal:  BMC Musculoskelet Disord       Date:  2016-03-15       Impact factor: 2.362

5.  Finite Element Analysis of a Bionate Ring-Shaped Customized Lumbar Disc Nucleus Prosthesis.

Authors:  Amparo Vanaclocha-Saiz; Vicente Vanaclocha; Carlos M Atienza; Pablo Clavel; Pablo Jorda-Gomez; Carlos Barrios; Leyre Vanaclocha
Journal:  ACS Appl Bio Mater       Date:  2021-12-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.